background image

Angular Style Air Gripper
Toggle Type

Series 

MHT2

Size: 32, 40, 50, 63

F9BW S

How to Order

Bore size

32 mm

32

Action

Auto switch

Applicable Auto Switch

/

Refer to page 12-13-1 for further information on auto switches.

Double acting

D

2 pcs.

1 pc.

S

“n” pcs.

n

Without auto switch

(Built-in magnet)

Nil

Nil

40 mm

40

50 mm

50

63 mm

63

D

32

MHT2

Number of auto 
switches

Toggle type 

air gripper

2 fingers

2

Number of fingers

Switch Mounting Bracket Part No.

Bore size

(mm)

32, 40
50, 63

BQ-2

Bracket

no.

Note

• Switch mounting screw 
 

(M3 x 0.5 x 10

l

)

• Switch spacer
• Switch mounting nut.

Reed switch
D-A7/A8
D-A73C/A80C
D-A7

H/A80H

D-A79W
Solid state switch
D-F7

/J79

D-F7

V

D-J79C
D-F7

W/J79W

D-F7

WV

D-F7BAL/F78AVL
D-F79F

Applicable 

auto switch

Type

Reed s

witch

Solid state s

witch

Special

function

Diagnosis

(2-color indication)

Diagnosis

(2-color indication)

Water resistant

(2-color indication)

With diagnosis

output 

(2-color indication)

Applicable

load

IC

circuit

Relay,

PLC

Relay,

PLC

IC

circuit

IC

circuit

IC

circuit

Electrical

entry

Pre-wire

connector

Grommet

Grommet

Grommet

Grommet

Connector

Connector

Wiring

(Output)

3-wire

(NPN equi.)

3-wire
(NPN)

3-wire
(PNP)

3-wire
(NPN)

3-wire
(PNP)

4-wire
(NPN)

2-wire

24 V

5 V

200 V

100 V

12 V

12 V

5 V

12 V

5 V

12 V

5 V

12 V

12 V

12 V

24 V

2-wire

2-wire

Load voltage

Rail mounting

Direct mounting Lead wire length (m)

DC

AC

Perpendicular

A76H

A96V

A96

In-line Perpendicular In-line

0.5

(Nil)

3

(L)

5

(Z)

None

(N)

Indicator light

Ye

s

Ye

s

A72

A73

A73C

A79W

F7NV

F7PV

F7BV

J79C

F7NWV

F7BWV

F7BAV

A72H

A73H

F79

F7P

J79

F79W

F7PW

J79W

F7BA

F79F

A93V

M9NV

M9PV

M9BV

F9NWV

F9PWV

F9BWV

A93

M9N

M9P

M9B

F9NW

F9PW

F9BW

F9BA

Lead wire length symbols: 0.5 m ··········· Nil (Example) F9BW

                                                 3 m ···········  L  (Example) F9BWL
                                                 5 m ···········  Z  (Example) F9BWZ
                                              None ···········  N  (Example) J79CN

 “ 

 

” marked solid state switches are produced upon receipt of order. 

• Refer to page 12-9-7 for details, because there are other auto
  switches available than above models.

Ideal for gripping 
heavy workpiece.

The toggle mechanism 
holds workpiece even 
when pressure drops.

Auto switch is 
attachable.

Model/Specifications

Model

Note) At the pressure of 0.5 MPa

Bore size (mm)

Action

Fluid

Operating pressure

Ambient and fluid temperature

Lubrication

Finger opening angle (Total)

Weight (kg)

Gripping moment 

Note)

(Effective value) (N·m)

MHT2-32D

MHT2-40D

MHT2-50D

MHT2-63D

32

40

Double acting

Air

0.1 to 0.6 MPa

5

 to 

60

°

C

Not required

50

63

–3

 to 

28

°

–3

 to 

27

°

–2

 to 

23

°

–2

 to 

23

°

0.80

1.09

1.93

2.8

12.4

36.0

63.0

106

Refer to page 12-13-25 for auto switch 
specifications. 

∗ 

For the applicable auto 

switch model, refer to the 
table below.

12-9-2

Summary of Contents for MHT2

Page 1: ...Angular Style Air Gripper Toggle Type Series MHT2 12 9 1 MHZ MHF MHL MHR MHK MHS MHC MHT MHY MHW MRHQ Misc D 20 ...

Page 2: ... wire 24 V 5 V 200 V 100 V 12 V 12 V 5 V 12 V 5 V 12 V 5 V 12 V 12 V 12 V 24 V 2 wire 2 wire Load voltage Rail mounting Direct mounting Lead wire length m DC AC Perpendicular A76H A96V A96 In line Perpendicular In line 0 5 Nil 3 L 5 Z None N Indicator light Yes Yes A72 A73 A73C A79W F7NV F7PV F7BV J79C F7NWV F7BWV F7BAV A72H A73H F79 F7P J79 F79W F7PW J79W F7BA F79F A93V M9NV M9PV M9BV F9NWV F9PWV...

Page 3: ...the thrust of one finger when both fingers and attachments are in full contact with the work piece as shown in the figure below Be sure to read before handling Refer to pages 12 15 3 to 12 15 4 for Safety Instructions and Common Precautions on the product mentioned in this catalog and refer to pages 12 1 4 to 12 1 6 for Precautions on every series Indication of effective gripping force L Gripping ...

Page 4: ... 4 M6 x 1 thread depth 15 Mounting thread 4 M6 x 1 bottom hole dia 5 1 Thread for mounting attachment 8 M8 x 1 25 mounting thread Thread depth 10 Both sides 4 M6 x 1 thread depth 10 Mounting thread Finger closing port Rc 1 8 Finger opening port Rc 1 8 Open 27 Closed 3 4 M8 x 1 25 thread depth 12 Mounting thread 4 M8 x 1 25 bottom hole dia 6 8 Thread for mounting attachment Series MHT2 12 9 4 ...

Page 5: ...0 x 5 bottom hole dia 8 6 Thread for mounting attachment Open 23 Closed 2 Finger closing port Rc 1 4 Finger opening port Rc 1 4 8 M12 x 1 75 mounting thread Thread depth 17 Both sides 4 M10 x 1 5 thread depth 18 Mounting thread 4 M12 x 1 75 thread depth 10 Mounting thread 4 M12 x 1 75 bottom hole dia 10 4 Thread for mounting attachment 12 9 5 Series MHT2 Angular Style Air Gripper Toggle Type MHZ M...

Page 6: ...ed acetal resin bearing Compact cylinder Attachment Design Use shims for fine adjustment of the attachment Component Parts Finger assembly Lever assembly Link parts assembly Compact cylinder wo e ø32 ø40 weryio ø50 ø63 werio 0 MHT2 32D MH TA3201 MH TA3202 MH TA3203 CDQ2A32 15D MHT2 40D MH TA4001 MH TA4002 MH TA4003 CDQ2A40 15D MHT2 50D MH TA5001 MH TA5002 MH TA5003 CDQ2A50 20D MHT2 63D MH TA6301 M...

Page 7: ...쏔V D M9쏔 D M9쏔V D F9쏔W D F9쏔WV Type Model Features Without indicator light Electrical entry direction D A80 D A80H D A80C D A90 D A90V Grommet Perpendicular Grommet In line Connector Perpendicular Grommet In line Grommet Perpendicular Reed switch Mounting of Auto Switch Auto Switch Hysteresis Rail mounting type Direct mounting type Hysteresis Switch operating position ON Switch reset position OFF ...

Page 8: ...oove in the direction shown in the following drawing Step 3 Slide the auto switch in the direction of the arrow until the indicator light illuminates Step 4 Slide the auto switch further in the direction of the arrow until the indicator light goes out Step 5 Move the auto switch in the opposite direction and fasten it at a position 0 3 to 0 5 mm beyond the position where the indicator light illumi...

Page 9: ... into the switch installation groove in the direction shown in the following drawing Step 3 Move the auto switch in the direction of the arrow and fasten it at a position 0 3 to 0 5 mm beyond the position where the indicator light illuminates Step 3 Slide the auto switch in the direction of the arrow until the indicator light illuminates Position where light turns ON Position to be secured Note 1 ...

Page 10: ...d experienced operators 3 Do not service machinery equipment or attempt to remove components until safety is confirmed 1 Inspection and maintenance of machinery equipment should only be performed once measures to prevent falling or runaway of the driver objects have been confirmed 2 When equipment is to be removed confirm the safety process as mentioned above Cut the supply pressure for this equip...

Page 11: ... qualified personnel only 3 Drain flushing Remove drainage from air filters regularly Refer to the specifications 4 Shut down before maintenance Before attempting any kind of maintenance make sure the supply pressure is shut of and all residual air pressure is released from the system to be worked on 5 Start up after maintenance and inspection Apply operating pressure and power to the equipment an...

Page 12: ... an international standard related to environmental management systems and environmental inspections While promoting environmentally friendly automation technology SMC is also making diligent efforts to preserve the environment Environmental management system ISO 14001 Sales coordination Production Make customers our first priority offering them reliable and friendly service Market research Produc...

Page 13: ...achinery Directive The Machinery Directive contains essential health and safety requirements for machinery as applied to industrial machines e g machine tools injection molding machines and automatic machines Pneumatic equipment is not specified in Machinery Directive However the use of SMC products that are certified as conforming to EN Standards allows customers to simplify preparation work of t...

Page 14: ...ation OSHA SMC was tested for compliance with CSA Standards and UL Standards at the same time and was approved for compliance with the two Standards The above CSA NRTL C logo is described on a product label in order to indicate that the product is approved by CSA and UL Standards TSSA MCCR Registration Products TSSA is the regulation in Ontario State Canada The products that the operating pressure...

Page 15: ...6 COLOMBIA Distributor Airmatic Ltda Calle 18 69 05 Apart Aereo 081045 Santa Fe de Bogotá Colombia TEL 1 424 9240 FAX 1 424 9260 U K SMC Pneumatics U K Ltd Vincent Avenue Crownhill Milton Keynes MK8 0AN Backinghamshire U K TEL 01908 563888 FAX 01908 561185 GERMANY SMC Pneumatik GmbH Boschring 13 15 D 63329 Egelsbach Germany TEL 06103 4020 FAX 06103 402139 ITALY SMC Italia S p A Via Garibaldi 62 I ...

Page 16: ...Sylvia Park Road Mt Wellington Auckland New Zealand TEL 09 573 7007 FAX 09 573 7002 TAIWAN SMC Pneumatics Taiwan Co Ltd 17 Lane 205 Nansan Rd Sec 2 Luzhu Hsiang Taoyuan Hsien TAIWAN TEL 03 322 3443 FAX 03 322 3387 HONG KONG SMC Pneumatics Hong Kong Ltd 29 F Clifford Centre 778 784 Cheung Sha Wan Road Lai Chi Kok Kowloon Hong Kong TEL 2744 0121 FAX 2785 1314 SINGAPORE SMC Pneumatics S E A Pte Ltd 8...