2. Specific Product Precautions (2) 

 

 

(3)  Check  the  model,  type  and  size  before 

installation. 

Also,  confirm  that  there  are  no 

scratches, gouges or cracks on the product.

 

(4) When connecting the tubing, take pressure 

or possible changes to the tubing length into 
account, and allow a sufficient margin. 

Failure to do so may result in fitting breakage or 
detachment  of  the  tubing.  Refer  to  the 
recommended piping conditions. 

(5)  Do  not  apply  unnecessary  forces  such  as 

twisting,  pulling,  moment  loads,  vibration 
and impact, etc. on fittings or tubing. 

This will cause damage to the fittings and will 
crush, burst or release tubing.

 

(6) Tubing, with the exception of coiled tubing, 

requires  stationary  installation.  Do  not  use 
standard tubing (non-coiled) in applications 
where tubing is required to travel inside the 
flexible  protection  tube.  Tubing  that  travels 
may  sustain  abrasion,  extension,  or 
severance due to tensile force, or may result 
in removal of tubing from fitting. Use caution 
prior to use for proper application. 

(7) To install the fitting, screw the fitting in using 

the hexagonal face of the body, and tighten 
with an appropriate wrench. 

Affix the wrench at the base of the thread. If the 
size of hexagonal face and wrench do not match, 
or tightening takes place near the tube side, it 
may  cause  collapse  or  deformation  of  the 
hexagonal  face,  or  damage  to  the  equipment. 
After installing, confirm that there is no damage 
to the fitting, etc. 

(8)  The  swivel  elbow  rotation  is  only  for 

positioning after mounting the product. 

 

It  is  not  intended  for  repeated  rotation  or 

oscillation,  which  will  cause  wear,  resulting  in 
metal  particles  which  may  enter  the  operating 
fluid or cause fitting damage. 

 
 

Caution

 

(1) Take a tube having no flaws on its periphery 

and  cut  it  off  at  right  angles.

  (Use  SMC's 

tube cutter TK-1, 2, 3, 5 or 6 for cutting. Do not 
use pinchers, nippers or scissors, etc.) 

The tubing might be cut diagonally or flattened, 
making  installation  impossible  or  causing 
problems such as disconnection and leakage. 

 

(2)  Insert  the  tube  into  the  union  nut  with  the 

union  nut  removed.  Grab  the  tube  and 
gently push it thoroughly into the fitting. 

 

(3)  After  insertion,  tighten  the  union  nut 

temporarily by hand. 

(4) Fix the body with a tool. Tighten the union 

nut to the end surface of the body using a 
suitable wrench. 

   

Hex. across flats may be deformed, if using 
an improper wrench for hex. across flats. 

   

  If the body is not secured with a tool, this may 

cause breakage. (In particular, for the swivel 
elbow, the stud may come off). 

 

 
 
 

 

 

 

 

 

(5) Fix the body with a tightening tool. Tighten 

the  union  nut  to  the  end  surface  of  the 
body using a suitable wrench. 

Hex. across flats may be deformed, if using 

an improper wrench for hex. across flats. 
Tighten  the  union  nut  with  the  proper 

tightening torque shown below. 

 
 

 

Fitting size 

Proper tightening torque [N

m] 

KFG2□01 

2 to 3 

KFG2□03 
KFG2□04 
KFG2□06 

3 to 4 

KFG2□07 
KFG2□08 

5 to 6 

KFG2□09 
KFG2□10 

8 to 10 

KFG2□11 

KFG2□12 

10 to 12 

KFG2□13 
KFG2□16 

16 to 18 

Piping Method

 

Body securing tool 

Union nut tightening tool 

Mounting/ Piping

 

 

Union nut tightening direction 

Summary of Contents for KFG2-F Series

Page 1: ...Document No KF OMY0034 A PRODUCT NAME FDA compliant Stainless Steel 316 Insert Fitting MODEL Series Product Number KFG2 F series...

Page 2: ...2 Contents 1 Safety Instructions 3 to 4 2 Specific Product Precautions 5 to 9 3 Specifications 10 to 11 4 Troubleshooting 11 5 Construction 12...

Page 3: ...to any possibility of equipment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe i...

Page 4: ...age incurred due to the failure of the product 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 2...

Page 5: ...r mm Twice against the minimum bending radius Test temperature 20 5o C Relative humidity 65 5 3 Do not use fluids other than listed on the specifications Applicable fluids are air water and steam Plea...

Page 6: ...8 The swivel elbow rotation is only for positioning after mounting the product It is not intended for repeated rotation or oscillation which will cause wear resulting in metal particles which may ente...

Page 7: ...lity such as by providing an aftercooler air dryer or water droplet separator 3 Ensure that the fluid and ambient temperature are within the specified range If the fluid temperature is 5o C or less th...

Page 8: ...pair the fittings or patch the tubing for reuse 4 After operation at a high temperature leakage may occur due to time dependent change of the tube material If leakage occurs remove the tube cut off th...

Page 9: ...hen using the KFG2 F series with tubing other than those from SMC the products are not subject to warranty Connection female Thread size Chamfer dimension D Recommended value mm M5 5 1 to 5 4 10 32UNF...

Page 10: ...nge of the tube Applicable tubing Note1 Considering the product application FDA compliant products are recommended Note2 For soft polyurethane tubing hard polyurethane tubing antistatic polyurethane t...

Page 11: ...03 F G1 2 KQB2 G04 F 4 Troubleshooting KFG2 series insert fitting cannot be disassembled or repaired in order to quality maintenance When failure such as Non removable tubing occurs please replace the...

Page 12: ...ide is more stable than pure metal Accordingly metallic material chemically oxidizes metallic constituent becomes ion and melts out It corrodes in the natural environment Even though corrosion of meta...

Page 13: ...Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL http www smcworld com NOTE Specifications are subject to change without prior notice and any obligation on the part of the manufacturer 2020 SMC Corporation A...

Reviews: