- 7 -
No.JXC#-OMX0009-A
2. Outlines of Product
2.1 Features
Features of the controller.
●CC-Link compatible
CC-Link operation is available by connecting with CC-Link. Information can be written and read to
and from it.
●Actuator control
Positioning operation and operation at a specific speed and force for the actuator are possible by
controlling the Step motor (servo 24VDC).
●Specified force operation
Control the pushing force or the pressing force of the actuator.
●Separated power supply
Power supply input is separated into the motor power supply and control power supply. Even if the
power supply for the motor is turned OFF, the information from the encoder position is not lost while
the control power supply is ON, and CC-Link communication and serial communication is available.
●Return to origin
Returning to origin is possible by a signal from CC-Link.
●Alarm detection function
Abnormal conditions are automatically detected. Alarms are output via CC-Link communication.
The alarm history can be stored in the controller memory.
●Positioning / pushing operation is available with step data and numerical operation mode
It is possible to operate the actuator by using the saved step data and by numeric data operation
instruction by using CC-Link communication.
In the step data operation mode, the operation is instructed by manipulating the memory which is
relevant to input/output port such as DRIVE signal and INP signal. The actuator operates in
accordance with the step data operating pattern of the specified step data.
In the numerical operation mode, the operation is executed by specifying the releveant numeric
data.
●”AREA” signal
The controller has an “AREA” signal that turns ON if the actuator position is within the range
specified by "Area 1" and "Area 2" in the step data.
●Data input method
It is possible to perform parameter setup, status monitoring, trial run and alarm reset via CC-Link
communication or the serial communication with a PC installed with the controller setting software
or the teaching box.
●Easy mode and Normal mode
There are two available modes for the controller setting software and the teaching box. In Easy
mode, you can start the operation by only setting the speed, position, etc. In Normal mode, further
detailed setup can be performed.
● Applicable for the Battery-Less Absolute Encoder
Detection of the absolute position enables the encoder to detect the actuator position when power is
supplied, so operation is available with no return to origin operation.
Caution
When the device is set up or failure occurs, please refer the operation manual of the actuator, the
teaching box, and controller setting software as well as this operation manual.
Keep this operation manual accessible for reference when necessary.