11.4 Operation parameters
This is data to set the JOG operation of the controller.
To change operation parameters, set the basic parameter "Parameter protection" to "3: Common +
Step".
Details of the operation parameters
Activation: “XX” = Become effective just after recorded into the controller,
“X” = Become effective after restarting the controller,
“-” = The parameter cannot be changed (fixed value).
Controller
setting
software
Range
Description
Acti-
vation
JOG speed
*1)
Defines the JOG operation speed. (Unit: 1 mm/s)
XX
JOG
acceleration
1 to "Max ACC/DEC"
of the basic parameter
Defines the JOG operation acceleration.
(Unit: 1 mm/s
2
)
XX
JOG
deceleration
1 to "Max ACC/DEC"
of the basic parameter
Defines the JOG operation deceleration.
(Unit: 1 mm/s
2
)
XX
JOG thrust
*1)
Defines the torque limit during JOG operation.
(Unit: 1%)
XX
Fixed distance
0.01 to Full stroke
*1)
Defines the Inching distance. (Unit: 0.01 mm)
XX
*1) This depends on the electric actuator. Set a value that is equal to or smaller than the catalogue
recommended value for positioning operation or pushing operation, according to the operating
manual for each
electric actuator.