- 21 -
No.JXC#-OMX0009-A
3.4 Mounting
(1) Mounting
The controller can be direct mounted using screws or mounted on a DIN rail.
Details of the controller mounting options are shown below.
①
Screw mounting
(
JXCM17#-#
)
②
DIN rail mounting
(
JXCM18#-#
)
(Mounting with two M4 screws) (Mounting with DIN rail)
DIN rail is locked
(2) Grounding
Place the grounding cable with crimped terminal between the M4 screw and shakeproof washer as shown
below and tighten the screw.
Controller
Caution
The M4 screw, cable with crimped terminal and shakeproof washer must be prepared by the user.
The controller must be connected to Ground to reduce noise.
If higher noise resistance is required, ground the 0V (signal ground).
When grounding the 0V, avoid flowing noise from the ground to the 0V
Shakeproof washer
Cable with crimping terminal
M4 screw
Hook the controller on the DIN rail and
press lever A in the direction of the arrow to lock it.
DIN rail
Ground wire
A
Mounting
direction
A
Mounting
direction
Ground wire
Ground wire