- 17 -
No.JXC#-OMX0009-A
3. Specifications
3.1 Specifications
(1) Basic specifications of the product.
Item
Specifications
Compatible motor
Step motor (servo 24 VDC)
Power supply
*1) *2)
Power supply voltage: 24 VDC +/-10%
Max. current consumption: 3A (Peak 5A)
*3)
(for both of motor drive power control power, stop, lock brake release)
Compatible encoder
Battery-less absolute encoder (resolution: 4096 pulses/rotation)
Serial communication
RS485
Memory
EEPROM
LED
display
LED
name
PWR
ALM
L ERR
L RUN
Details
Power supply Alarm status
CC-Link
Error status
CC-Link
Communication
status
Locking
Unlocking terminal (applicable to non-exitation magnetizing lock)
Cable length
Actuator cable: 20 m or less
Cooling method
Air-cooling type
Operating temperature
range
0
o
C to 55
o
C (No freezing)
*4)
Operating humidity
range
90% RH or less (No condensation)
Storage temperature
range
-10
o
C to 60
o
C (No freezing)
Operating humidity
range
90% RH or less (No condensation)
Insulation resistance
Between the external terminals and case
50 MΩ (500VDC)
Weight
170 g (Direct mounting type)
190 g (DIN rail mounting type)
*1) The controller power supply
do not use the power supply of “inrush current restraining type”.
*2) When conformity to UL is required, the electric actuator and controller should be used with a UL1310
Class 2 power supply.
*3) The power consumption changes depending on the electric actuator model.
Please refer to the specifications of the electric actuator for more details.
*4)
For the LEY40 and LEYG40 series, if the vertical transfer load is greater than the weight listed
below, the controller must be used at an ambient temperature of 40
o
C or less.
LEY40□EA: 9 kg, LEY40□EB: 19 kg, LEY40□EC: 38 kg
LEYG40□EA: 7 kg, LEYG40□EB: 17 kg, LEYG40□EC: 36 kg