(2) Grounding
Fit the grounding cable with
crimped terminal between
the M3 screw and
shakeproof washer as
shown below and tighten
the screw.
JXC-TFT34
Refer to the operation manual on SMC website
(URL http://www.smcworld.com).
6 Power supply connector
The figure below shows how
to mount the controller to the
DIN rail. Hook part A on to the
DIN rail. Press part B on to the
DIN rail and tighten the locking
screws (M5 x 14).
(Appropriate tightening torque:
0.4 to 0.6 Nm)
Locking screw M5 x 14
Part B
Part A
Shakeproof washer
M3 screw
Grounding cable
(with crimped terminal)
Caution
The cable with crimped terminal and shakeproof washer must be
prepared by the user.
The controller must be connected to Ground to reduce noise.
Refer to the operation manual on SMC website
(URL http://www.smcworld.com).
Caution
Connector specifications
The power supply connector included is shown below.
(1) Main control power supply connector: C PWR
(2) Motor drive power connector: M PWR
Specifications of the cable are as follows.
Use the power cable for main control, JXC-C1.
Terminal
Function
Description
+24V
Main control
power )
Power ) for main
control.
24-0V
Main control
power supply(-)
Power supply(-) for main
control.
Brown
+24V
24-0V
Blue
Terminal
Function
Description
0V
Motor power(-)
Power supply(-) common for
M24V terminal, C24V terminal,
EMG terminal and LKRLS
terminal
M24V
Motor power(+)
Motor drive power ) for
Axis 1 and 2 or Axix 3 and 4.
0V
M24V
Item
Specifications
Wire size
Stranded wire → AWG20 (0.5mm
2
)
O.D. of sheath →ø1.76
Wire sheath colour
+24V: Brown
24-0V: Blue
Prepare the electrical wiring according to the following specifications
(to be prepared by the user).
When the wire is inserted into the motor drive power connector, insert
only the stripped part of the wire.
Manufactured by Phoenix Contact
(Part number MSTB2,5/2-STF-5,08)
Item
Specifications
Applicable wire size
Single, Stranded wire → AWG16 (1.25mm
2
)
The rated temperature of the insulation coating
should be 60
o
C or more.
Stripped wire length
7mm
ø3.4 or less
(3) Motor control power supply connector: CI
Prepare the electrical wiring according to the following specifications
(to be prepared by the user).
Manufactured by Phoenix Contact
(Part number FK-MC0,5/5-ST-2,5)
Item
Specifications
Applicable wire size
Single, Stranded wire → AWG20 (0.5mm
2
)
The rated temperature of the insulation coating
should be 60
o
C or more.
Stripped wire length
8mm
ø2.0 or less
E
M
G
1/
E
M
G
3
E
M
G
2/
E
M
G
4
LK
R
LS
2/
LK
R
LS
4
C
24
V
LK
R
LS
1/
LK
R
LS
3
Terminal
Function
Description
C24V
Motor control
power )
Power supply side(+) for motor
control.
EMG1/
EMG3
Stop(+)
Release the stop ) of
Axis 1 or Axis 3.
(Normal operation by applying
24V.)
EMG2/
EMG4
Stop(+)
Release the stop ) of
Axis 2 or Axis 4.
(Normal operation by applying
24V.)
LKRLS1/
LKRLS3
)
Release the lock ) of
Axis 1 or Axis 3.
LKRLS2/
LKRLS4
)
Release the lock ) of
Axis 2 or Axis 4.
Do not connect multiple wires into one terminal.
Contact failure or short circuit to adjacent wire may lead to malfunction or
fire.
URL http://www.smcworld.com (Global) http://www.smceu.com (Europe)
Specifications are subject to change without prior notice from the manufacturer.
© 2016 SMC Corporation All Rights Reserved
11 Contacts
AUSTRIA
(43) 2262 62280-0
NETHERLANDS
(31) 20 531 8888
BELGIUM
(32) 3 355 1464
NORWAY
(47) 67 12 90 20
CZECH REP.
(420) 541 424 611
POLAND
(48) 22 211 9600
DENMARK
(45) 7025 2900
PORTUGAL
(351) 21 471 1880
FINLAND
(358) 207 513513
SLOVAKIA
(421) 2 444 56725
FRANCE
(33) 1 6476 1000
SLOVENIA
(386) 73 885 412
GERMANY
(49) 6103 4020
SPAIN
(34) 945 184 100
GREECE
(30) 210 271 7265
SWEDEN
(46) 8 603 1200
HUNGARY
(36) 23 511 390
SWITZERLAND
(41) 52 396 3131
IRELAND
(353) 1 403 9000
UNITED KINGDOM
(44) 1908 563888
ITALY
(39) 02 92711
BULGARIA
(359) 2 974 4492
ESTONIA
(372) 651 0370
ROMANIA
(40) 21 320 5111
LATVIA
(371) 781 77 00
LITHUANIA
(370) 5 264 8126
7 How to order
8 Outline with Dimensions (mm)
9 Maintenance
10 Troubleshooting
Refer to the operation manual on the SMC website
(URL http://www.smcworld.com).
(b) DIN rail mounting
The figure on the right shows
how to mount the DIN rail
mounting brackets.
Secure the DIN rail mounting
bracket using 4 mounting
screws (M5 x 8 mm) 2 on
each side. (Appropriate
tightening torque: 3.0 Nm)
Secure the DIN rail mounting
bracket using 2 locking
screws (M5 x 14 mm), 1 on
each side. Tighten for
approximately 2 threads.
Do not tighten completely.
5 Mounting
(1) Mounting
There are two ways to mount the controller.
(Direct mounting and DIN rail mounting)
Controller mounting methods are shown below.
(a) Direct Mounting with four M5 screws
Mounting screw (M5) 4pcs.
(prepared by user)
Mounting screw M5 x 8
Included with DIN rail
mounting bracket
Tightening torque: 3.0 (Nm)
Locking screw M5 x 14
Included with DIN rail
mounting bracket
Tightening torque: 0.4 to 0.6 (Nm)
[
]
[
]
When the wire is inserted into the motor control power supply connector,
insert only the stripped.