background image

(2) Grounding

Fit the grounding cable with
crimped terminal between
the M3 screw and
shakeproof washer as
shown below and tighten
the screw.

JXC-TFT34

Refer to the operation manual on SMC website
(URL http://www.smcworld.com).

6 Power supply connector

The figure below shows how
to mount the controller to the
DIN rail. Hook part A on to the
DIN rail. Press part B on to the
DIN rail and tighten the locking
screws (M5 x 14).
(Appropriate tightening torque:
0.4 to 0.6 Nm)

Locking screw M5 x 14

Part B

Part A

Shakeproof washer

M3 screw

Grounding cable
(with crimped terminal)

Caution

The cable with crimped terminal and shakeproof washer must be
prepared by the user.
The controller must be connected to Ground to reduce noise.

Refer to the operation manual on SMC website
(URL http://www.smcworld.com).

Caution

Connector specifications

The power supply connector included is shown below.
(1) Main control power supply connector: C PWR

(2) Motor drive power connector: M PWR

Specifications of the cable are as follows.

Use the power cable for main control, JXC-C1.

Terminal

Function

Description

+24V

Main control
power )

Power ) for main
control.

24-0V

Main control
power supply(-)

Power supply(-) for main
control.

Brown

+24V

24-0V

Blue

Terminal

Function

Description

0V 

Motor power(-)

Power supply(-) common for
M24V terminal, C24V terminal,
EMG terminal and LKRLS
terminal

M24V

Motor power(+)

Motor drive power ) for
Axis 1 and 2 or Axix 3 and 4.

0V

M24V

Item

Specifications

Wire size

Stranded wire → AWG20 (0.5mm

2

)

O.D. of sheath →ø1.76

Wire sheath colour

+24V: Brown
24-0V: Blue

Prepare the electrical wiring according to the following specifications
(to be prepared by the user).

When the wire is inserted into the motor drive power connector, insert
only the stripped part of the wire.

Manufactured by Phoenix Contact
(Part number MSTB2,5/2-STF-5,08)

Item

Specifications

Applicable wire size

Single, Stranded wire → AWG16 (1.25mm

2

)

The rated temperature of the insulation coating
should be 60

o

C or more.

Stripped wire length

7mm

ø3.4 or less

(3) Motor control power supply connector: CI

Prepare the electrical wiring according to the following specifications
(to be prepared by the user).

Manufactured by Phoenix Contact
(Part number FK-MC0,5/5-ST-2,5)

Item

Specifications

Applicable wire size

Single, Stranded wire → AWG20 (0.5mm

2

)

The rated temperature of the insulation coating
should be 60

o

C or more.

Stripped wire length

8mm

ø2.0 or less

E

M

G

1/

E

M

G

3

E

M

G

2/

E

M

G

4

LK

R

LS

2/

LK

R

LS

4

C

24

V

LK

R

LS

1/

LK

R

LS

3

Terminal

Function

Description

C24V

Motor control
power )

Power supply side(+) for motor
control.

EMG1/

EMG3

Stop(+)

Release the stop ) of
Axis 1 or Axis 3.
(Normal operation by applying
24V.)

EMG2/

EMG4

Stop(+)

Release the stop ) of
Axis 2 or Axis 4.
(Normal operation by applying
24V.)

LKRLS1/

LKRLS3

)

Release the lock ) of
Axis 1 or Axis 3.

LKRLS2/

LKRLS4

)

Release the lock ) of
Axis 2 or Axis 4.

Do not connect multiple wires into one terminal.
Contact failure or short circuit to adjacent wire may lead to malfunction or
fire.

URL http://www.smcworld.com (Global) http://www.smceu.com (Europe)

Specifications are subject to change without prior notice from the manufacturer.
© 2016 SMC Corporation All Rights Reserved

11 Contacts

AUSTRIA

(43) 2262 62280-0

NETHERLANDS

(31) 20 531 8888 

BELGIUM

(32) 3 355 1464 

NORWAY

(47) 67 12 90 20 

CZECH REP.

(420) 541 424 611 

POLAND

(48) 22 211 9600 

DENMARK

(45) 7025 2900 

PORTUGAL

(351) 21 471 1880

FINLAND

(358) 207 513513 

SLOVAKIA

(421) 2 444 56725 

FRANCE

(33) 1 6476 1000 

SLOVENIA

(386) 73 885 412

GERMANY

(49) 6103 4020 

SPAIN

(34) 945 184 100 

GREECE

(30) 210 271 7265 

SWEDEN

(46) 8 603 1200 

HUNGARY

(36) 23 511 390 

SWITZERLAND

(41) 52 396 3131 

IRELAND

(353) 1 403 9000 

UNITED KINGDOM

(44) 1908 563888 

ITALY

(39) 02 92711

BULGARIA

(359) 2 974 4492

ESTONIA

(372) 651 0370 

ROMANIA

(40) 21 320 5111

LATVIA

(371) 781 77 00 

LITHUANIA

(370) 5 264 8126 

7 How to order
8 Outline with Dimensions (mm)
9 Maintenance
10 Troubleshooting

Refer to the operation manual on the SMC website
(URL http://www.smcworld.com).

(b) DIN rail mounting

The figure on the right shows
how to mount the DIN rail
mounting brackets.
Secure the DIN rail mounting
bracket using 4 mounting
screws (M5 x 8 mm) 2 on
each side. (Appropriate
tightening torque: 3.0 Nm)
Secure the DIN rail mounting
bracket using 2 locking
screws (M5 x 14 mm), 1 on
each side. Tighten for
approximately 2 threads. 
Do not tighten completely.

5 Mounting

(1) Mounting

There are two ways to mount the controller.
(Direct mounting and DIN rail mounting)
Controller mounting methods are shown below.
(a) Direct Mounting with four M5 screws

Mounting screw (M5) 4pcs.
(prepared by user)

Mounting screw M5 x 8

Included with DIN rail
mounting bracket

Tightening torque: 3.0 (Nm)

Locking screw M5 x 14

Included with DIN rail
mounting bracket

Tightening torque: 0.4 to 0.6 (Nm)

[

]

[

]

When the wire is inserted into the motor control power supply connector,
insert only the stripped.

Reviews: