background image

 

WARNING 

1. This product is made for general industry. Contact SMC before use, if you are planning to use for 

other purposes.     

 

2. Use under specified voltage and temperature.   

Voltage out of specification may cause malfunction, breakage, electric shock and fire.   

 

3. Use clean compressed air for fluid.   

The construction of this product is not explosion proof. Do not use fluid such as inflammable gas or 

explosive gas or use in atmosphere including such a gas. It may result in fire or explosion. 

When using fluid other than compressed air, contact SMC. 

 

CAUTION

 

1. This product has not been washed.   

When bringing into clean room. Use after confirming its purification level after flushing. 

 

 

WARNING 

1. Get required space for maintenance, wiring and piping at installation. 

Install connector and One-touch fitting for air supply to be able to eliminate and mount cable and tube.     

Do not bend cable and tube with steep angle but fix them straight considering minimum bending 

radius to prevent forcible stress applied to installation base of connector and One-touch fitting.   

Forcible installation and elimination may cause malfunction, broken wire, fire and air leakage.   
Minimum bending radius: Power supply cable

20mm 

 

  Sensor cable

20 mm 

Note: Here is allowable bending radius when fixing wiring at 20

o

C. If bending cable at lower 

temperature, it may apply forcible force to connector even with minimum bending radius or more.

 

    See instruction or catalog for minimum bending radius fo tube. 

 

2. Install on the plane face. 

Forcible force may apply to frame or case due to concave and convex or deformed mounting face and 

large level gap, and it may cause breakage or operation failure. Also, dropping or strong impact may 

cause operation failure or accident. 

 

3. Do not install with strong electromagnetic source. 

Installation with strong electromagnetic source may cause malfunction. Install on the different panel 

or separate the mounting. 

 
4. Tighten within the specified torque.

tightening torque: See “4. Installation”

 

When exceeding the tightening torque, mounting screw and mounting bracket etc. might be broken.   

The screw might loosen for less than range of the tightening torque. 

 

5. Do not touch electrode needle with finger or metal tool directly. It may cause injury. 

If electrode needle or cartridge is damaged by tools, it will not only interfere the specification function 

and performance but also may cause operation failure or accident.   

 

6. Be sure to install and adjust after power supply is stopped. 

 

CAUTION

 

1. Install IZS30 series with keeping distance from the wall etc. as shown in the figure below. 

The generated ion might not reach the target effectively and efficiency decrease, where there is wall 

etc. inside the area shown in the figure below. 

 

 

Selection 

Installation

 

Summary of Contents for IZS30 SERIES

Page 1: ...AL PRODUCT NAME Ionizer MODEL IZS30 Series Read this operation manual carefully to understand before installation and operation Pay extra attention on the clause concerning the safety Keep this operation manual available whenever necessary ...

Page 2: ...tallation of surface electric potential sensor 9 4 3 Connection of cable 10 5 Function description 15 5 1 Operation mode 15 5 2 Output signal 16 5 3 Function description of indication 16 6 Selection and setting of equipment 17 6 1 Sensing DC mode 17 6 2 Pulsed DC mode DC mode 17 7 Technical data 18 7 1 Static charge elimination characteristics reference 18 7 2 Outline dimensions 22 ...

Page 3: ...ery and equipment This product generates high voltage so it can be dangerous if an operator is unfamiliar with it Assembly handling or repair of systems should be performed by trained and experienced operators 3 Do not service machinery equipment or attempt to eliminate components until safety is confirmed 1 Inspection and maintenance of the machinery and equipment should be performed after confir...

Page 4: ...g at 20o C If bending cable at lower temperature it may apply forcible force to connector even with minimum bending radius or more See instruction or catalog for minimum bending radius fo tube 2 Install on the plane face Forcible force may apply to frame or case due to concave and convex or deformed mounting face and large level gap and it may cause breakage or operation failure Also dropping or s...

Page 5: ...ss take measure to prevent freezing Though ambient temperature is within specification dew condensation might be generated where temperature is suddenly changed Therefore do not use under such environment 2 Environment to avoid Do not use or store under the following environments as these may cause operation failure If it is unavoidable take the appropriate measures a The place where ambient tempe...

Page 6: ... static electricity due to worn out after cleaning replace it with the new one In order to maintain the stable performance regular maintenance and cleaning of electrode are recommended 2 Stop supplying power to the body without fail when cleaning the electrode needle or exchanging the electrode cartridge Do not ouch the electrode needle while energizing or it may cause electric shock or accident 3...

Page 7: ...t mounted Part name D Sensor Type 1 Rotary sector type Type S For sensor 3m P For power supply 3m Part name C Cable Type E For body end M For body middle part S For sensor Part name B Bracket Part name N Electrode Needle cart Type T Tungsten For mounted two brackets for body end are attached Number of attached bracket for body middle part is by the bar length See below Ionizer For mounted sensor c...

Page 8: ...n collector or no voltage contact signal High volt error Sensor error Output signal Static elimination completed FET Open Drain DC28V 100mA or less Effective elimination distance 50 to 2000mm Sensing DC mode 200 to 2000mm Ambient temperature 0 to 50o C Ambient humidity 35 to 80 Rh No dew condensation Material Ionizer cover ABS Electrode Tungsten Vibration resistance Endurance 50Hz Amplitude 1mm 2 ...

Page 9: ...haracteristics reference Static charge elimination area See See 2 Static charge elimination area of 6 1 Static charge elimination characteristics reference 1 Mount end brackets on both sides of the ionizer body with the attached M4 threads Recommended tightening torque for M4 thread 0 75Nm 2 Mount intermediate brackets on the ionizer body at regular interval Note No intermediate bracket is attache...

Page 10: ...charge Note Install so that the detecting hole will be within 50mm from the surface of target s static charge In case of using a surface electric potential sensor install it so that the distance between the object for static charge elimination and the ionizer stays 200 or more 1 Mount a sensor bracket on the surface electric potential sensor with the attached M5 thread Recommended tightening torqu...

Page 11: ...5 of bracket Recommended tightening torque for detent thread 1 5 Nm 4 3 Connection of cable 1 Insert the modular plug of power supply cable ZS30 CP into the modular jack for indicating power on the ionizer body A lever will snap when the modular plug is correctly locked Fix cables with a tie wrap or other measures in the vicinity of connection not to apply compulsive force to the modular jack and ...

Page 12: ...e wrap or other measures in the vicinity of connection not to apply compulsive force to the modular jack and plug Direction of plugs on both sides of cable can be changed Pin Lead wire color Description Function 1 Brown DC21 6 to 26 4V Power supply DC 24 V 2 Blue GND Power supply 0V Be sure to apply class D grounding 3 Green NC 4 Gray Stop signal of static charge elimination Connected 0V during op...

Page 13: ...e wrap or other measures in the vicinity of connection not to apply compulsive force to the modular jack and plug Direction of plugs on both sides of cable can be changed Pin Lead wire color Description Function 1 Brown DC21 6 to 26 4V Power supply DC 24 V 2 Blue GND Power supply 0V Be sure to apply class D grounding 3 Green NC 4 Gray Stop signal of static charge elimination Connected 0V during op...

Page 14: ...modular jack of the electric potential sensor If the modular plug is properly inserted and locked a lever clicks to notify it s locked Fix cables with a tie wrap or other measures in the vicinity of connection not to apply compulsive force to the modular jack and plug Modular plug ...

Page 15: ...minal to GND during operation Discharge stops when terminal 4 is open 5 Signal for abnormal High voltage White Output Tr1 in ionizer is ON when abnormal signal is being sent 6 Signal for abnormal sensing Orange Output Tf2 in ionizer is ON is conducted when abnormal signal is being sent 8 Signal for static charge elimination completion Yellow Output Tr 3 in ionizer is ON when static charge eliminat...

Page 16: ...ricity Work moving fast Work which size is smaller than sensing detection area Static charge elimination of space or continuum Pulsed DC mode Discharge plus and minus ion in the frequency of 1Hz to 33Hz by returns Although surface electric potential sensor cannot properly decide the target s static charge such as space or continuum stable ion balance can eliminate the static electricity 1 Since st...

Page 17: ...ion is being generated 4 Indication for static charge elimination completion Light on Green when static charge elimination is completed at sensing DC mode 5 Plus indication Light on Orange while plus ion is being generated 6 Indication for abnormal high voltage Light on Red when abnormal current such as high Voltage leakage is generated 7 Indication of abnormal sensing Light on Red when surface el...

Page 18: ...t not be obtained without both side piping 6 2 Pulsed DC mode DC mode 1 Selection of bar length Select the length applicable to work size base on 2 static charge elimination area of 7 1 static charge elimination characteristics reference 2 Installation of ionizer body Install within 50mm to 2000mm from the target s static charge See data of 1 Installation distance and static charge elimination tim...

Page 19: ...elimination time With air purge Installation distance mm Static charge elimination time sec Air purge flow rate 20 B min ANR Operating frequency C W O sensorD 33Hz W O sensor With sensor Target s static charge work Charged plate Dimension 150 150mm Capacity 20pF Meas Cond Static el Time for 3kV 0 3kV Installation distance and static charge elimination time W O air purge Operation frequency w o sen...

Page 20: ...UU 300 to IZS30 UUUU 1900 VVVV E F E G0E E G F E H E E I H F E I H E E I G F E I G0E E I F E E F E G0E E G F E H E E H F E E F E F E G0E E E G0E E F E F E W XSY W XSY W XSY W XSY ZZZZ X W X W X W X W ZZZZ X W X W X W X W ZZZZ Target s work of static charge Charged plate dimensions 150 150mm Capacity 20 F Meas Cond static elimination time for 3kV 0 3kV Ionizer width direction installed position of ...

Page 21: ... of target s static charge mm Target s work of static charge Charged plate dimensions 150 150mm Capacity 20 F Meas Cond static elimination time for 1kV 0 1kV Air purge amount 20l min ANR Surface potential Sensor N A Op Frequency 33Hz Ionizer depth direction Installed position of target s static charge mm 300 to 1900 TTTT IZS30 UUUU 300 to IZS30 UUUU 1900 VVVV Ionizer depth direction Installed posi...

Page 22: ...ensor 33Hz W O Sensor With Sensor Charge amount Target s work of static charge Charged plate dimensions 150 150mm Capacity 20 F Installation distance mm Static charge elimination time sec Installation distance and static charge elimination time Air purge N A With Sensor W O Sensor Target s work of static charge Charged plate dimensions 150 150mm Capacity 20 F Meas Cond static elimination time for ...

Page 23: ...f g0h i0h f jk je d l 2X4 M4X0 7 Depth 5 For mounting g l m hSnpo qsrtd_u v h i i d l af af 8P Modular jack For power supply cable plug 6P Modular jack For sensor cable plug Electrode cartridge w x0y0i0h z TrimmerforajustingI B Switchforselectingfrequency n Number of Cartriges Model n L mm IZS30 300 3 300 IZS30 780 9 780 IZS30 1260 15 1260 IZS30 1500 18 1500 IZS30 1900 23 1900 Installation distanc...

Page 24: ...ZS30 BM h d l g0i dQ j ak Thread for mounting M5 Should be prepared by user Angle ajustment available 90 ab j abf e gMi dQ j eb f e Thread for mounting M5 Should be prepared by user dQh o g iSu Attached thread M4X10L Angle ajustment available 90 ...

Page 25: ...ensor bracket IZS30 BS Detecting hope eb m l i l 6P Modular jack For Sensor plug for cable 2X2 M5X0 8 dpt6 2 M5X0 8 dpt7 ab eb g0h ab eb b dQ a b Mounting hole 8 a ea Attached thread M5x0 8 IZS30 D1 Shaft 8 for mounting Should be prepared by user ...

Page 26: ... Power supply cable IZS30 CP Sensor cable IZS30 CS ...

Reviews: