Funct
i
on
s
Error
description
Over-
current
error
OUT1
OUT2
Description
Solution
LCD
display
Load current of switch
output exceeds 80 mA.
Shut off the power
supply. After elimi-
nating the output
factor that caused
the excess current,
turn the power
supply back on.
Residual
pressure
error
A pressure level grea-
ter than
±
7%F.S. has
been applied when it
is cleared to zero. The
switch will automati-
cally return to measu-
ring mode in three se-
conds, however. Due
to individual product
differences, the set-
ting range varies by
±
1 digit.
Bring the pressure
back to atmospheric
pressure and try
using the zero-out
function.
Applied
pressure
error
Supply pressure ex-
ceeds the maximum
set pressure.
Bring the pressure
back to within the
set pressure range.
Supply pressure is be-
low the minimum set
pressure.
System error
Internal data error
Internal data error
Internal data error
Internal data error
Shut off the power
supply. Turn the po-
wer supply back on.
Note) When the display calibration function is used, the set pressure value
may change
±
1 digit.
0
Applied pressure
+
:
:
Factory setting display value
set prior to shipment
Display calibration range
±
5%R.D.
Displayed pressure value
D
is
play cal
i
b
r
at
i
on funct
i
on
This function eliminates slight differences in the output values and
allows uniformity in the numbers displayed. Displayed values of the
pressure sensor can be calibrated to within
±
5% of their readings.
Peak/Bottom hold funct
i
on
This function constantly detects and updates the maximum and mini-
mum pressure values and allows the unit to hold the display value.
Key lock funct
i
on
This function prevents incorrect operations such as changing the set
value accidentally.
Ze
r
o-out funct
i
on
The measured pressure reading can be adjusted to zero. More speci-
fically, the factory-set reading can be corrected to within
±
7%F.S.
Un
i
t d
is
play
s
w
i
tch
i
ng funct
i
on
The reading unit can be selected.
Ant
i
-chatte
ri
ng funct
i
on
A large bore cylinder or ejector consumes a large amount of air in
operation and may experience a temporary drop in the primary pres-
sure. This function prevents detection of such temporary drops in pri-
mary pressure as abnormal pressure.
Response time selections: 20 ms, 160 ms, 640 ms, 1000 ms, 2000 ms
E
rr
o
r
funct
i
on
Take the following corrective solutions when error occurs.
∗
If the switch does not recover to normal even after all of the above-
mentioned solutions have been applied, consult SMC for investiga-
tion.
Note 1) Output -27 and -67 only.
Unit/Reading resolution
MPa
kgf/cm
2
bar
psi
I
S
E70
0.01
0.1
0.1
1
I
S
E75/75H
0.1
1
1
1 (X10)
Note 1)
P
r
e
ss
u
r
e D
is
play Range
I
S
E75
I
S
E75H
0, 0.4 to 10.0 MPa
0, 0.5 to 15.0 MPa
Cut-to-zero display function “ON”
Series
Cut-to-zero display function “OFF”
0 to 10.0 MPa
0 to 15.0 MPa
∗
The set pressure range does not change when the cut-to-zero display function is disabled.
I
S
E75-
쏔
(for 10 MPa)
Cut-to-zero display function “ON”: 0
→
Displayed as 0
→
0.4
→
0.5
→
0.6
→
······
→
9.9
→
10.0
Cut-to-zero display function “OFF”: 0
→
0.1
→
0.2
→
0.3
→
0.4
→
0.5
→
0.6
→
······
→
9.9
→
10.0
I
S
E75H-
쏔
(for 15 MPa)
Cut-to-zero display function “ON”: 0
→
Displayed as 0
→
0.5
→
0.6
→
······
→
14.9
→
15.0
Cut-to-zero display function “OFF”: 0
→
0.1
→
0.2
→
0.3
→
0.4
→
0.5
→
0.6
→
······
→
14.9
→
15.0
Example p
r
e
ss
u
r
e d
is
play
s
(shading indicates changed displays)
Cut-to-ze
r
o d
is
play funct
i
on
With the ISE75 series, users can enable or disable a function (cut-to-zero display function) that displays pressure values of 0.3 MPa or less as ze-
ro (0.4 MPa or less in the ISE75H series).
Series
ISE75/75H
2-Colou
r
D
is
play D
i
g
i
tal P
r
e
ss
u
r
e
S
w
i
tch
Fo
r
Gene
r
al Flu
i
d
s
6