4 Installation (continued)
4.3.2 Connection using One-touch fitting
1. Cut the tube end perpendicular.
2. Hold the tube and insert it into the One-touch fitting slowly until it
bottoms out.
•
Allow sufficient tube length to prevent twist and tensile or moment
loads from being applied to the fitting or tube.
•
When using a tube manufactured by a company other than SMC,
check that its outside diameter tolerance satisfies the following values:
1) Nylon tube: ±0.1 mm maximum
2) Soft nylon tube: ±0.1 mm maximum
3) Polyurethane tube: +0.15 mm / -2 mm maximum
4.4 Vent Tube attachment
•
When the product is used in a place where water and dust splashes
may occur, insert a tube into the atmospheric vent port, and route the
other end of the tube to a safe place away from water and dust.
•
Insert the tube into the atmospheric vent port until it bottoms out.
SMC TU0425 (polyurethane, O.D
φ
4, I.D
φ
2.5) is a suitable tubing.
4.5 Lubrication
Caution
•
SMC products have been lubricated for life at manufacture, and do not
require lubrication in service.
•
If a lubricant is used in the system, use turbine oil Class 1 (no additive),
ISO VG32. Once lubricant is used in the system, lubrication must be
continued because the original lubricant applied during manufacturing
will be washed away.
5 Wiring
5.1 Wiring connections
•
Connections should be made with the power supply turned off.
•
Use a separate route for the product wiring and any power or high
voltage wiring. Otherwise, malfunction may result due to noise.
•
If a commercially available switching power supply is used, be sure to
ground the frame ground (FG) terminal. If the switching power supply is
connected for use, switching noise will be superimposed and it will not
be able to meet the product specifications. In that case, insert a noise
filter such as a line noise filter/ferrite between the switching power
supplies or change the switching power supply to a series power supply.
•
Tighten the connector by hand.
1
DC (+)
3
DC (-)
4
OUT
6 Pressure Setting
6.1 Measurement mode
The measurement mode is the condition where the pressure is detected
and displayed, and the switch function is operating.
This is the basic mode, and other modes should be selected for setting
changes and other function settings.
Setting the ON and OFF points of the Pressure switch.
•
Operation
When the pressure exceeds the set point, the Pressure switch will be
turned ON.
When the pressure falls below the set point by the amount of hysteresis
or more, the Pressure switch will be turned OFF.
The default setting of the output set value is the central value between
the atmospheric pressure and the upper limit of the rated pressure
range.
If this condition, shown below, is acceptable, then keep these settings.
6.2 Operation
[Hysteresis mode]
1, Press the
button once in measurement mode.
2, [P_1] or [n_1] and the set value are displayed in turn.
3, Press the
or
button to change the set value.
The
button is to increase and the
button is to decrease.
•
Press the
button once to increase by one digit, and press it
continuously to keep increasing the set value.
6 Pressure Setting (continued)
Press the
button once to decrease by one digit, and press it
continuously to keep decreasing the set value.
4, Press the
button to finish the setting.
For models with 2 outputs, [P_2] or [n_2] will be displayed. Set as
above.
The Pressure switch operates within a set pressure range (from P1L to
P1H) during window comparator
mode. Set P1L (switch lower limit) and P1H (switch upper limit) with the
setting procedure above.
(When reversed output is selected, [n1L] and [n1H] are displayed.)
Zero clear of Display
The display is reset to zero when the
and
buttons are pressed
simultaneously for 1 second. For the first operation, always perform zero
clear with no pressure applied.
7 Function Setting
In measurement mode, press the
button for 2 seconds or longer to
display [F 0]. Select to display the function to be changed, [F ## ].
Press the
button for 2 seconds or longer in function selection mode
to return to measurement mode.
*: Some functions are not available depending on part number. All functions are
displayed with [F ##] followed by the function description. If a function is not
available, the function is displayed as [---].
7.1 Default Function settings
At the time of shipment, the following settings are provided.
If this condition is acceptable, then keep these settings.
To change the settings, enter function selection mode.
•
[F 0] Unit
selection function.
Unit specification
Model
Default setting
Nil or M
ISE40A
MPa
ZSE40A(F)
kPa
P
ISE40A
psi
ZSE40A(F)
7 Function Setting (continued)
•
[F 1]
Setting of OUT1
Item
Description
Default setting
Output mode
Select hysteresis mode or
window comparator mode.
Hysteresis mode
Reversed
output
Select reversed output.
Normal output
Pressure
setting
Set the ON or OFF point of
the switch output
ISE40A: 0.500 MPa
ZSE40A: -50.7 kPa
ZSE40AF: 50.0 kPa
Hysteresis
Set the hysteresis to prevent
chattering.
ISE40A: 0.050 MPa
ZSE40A: 5.1 kPa
ZSE40AF: 5.0 kPa
Display
colour
Select the display colour.
ON: Green
OFF: Red
•
[F 2]
Setting of OUT2 is the same setting as [F 1] OUT1.
The display colour is linked to OUT1 and cannot be set for OUT2.
•
Other parameter settings
Item
Default setting
[F 3] Response time
2.5 ms
[F 4] Auto-preset function
Manual
[F 5] Setting of analogue output / auto-shift input
Analogue output
[F 6] Fine adjustment of display value
0%
[F11] Display resolution
1000-split
[F80] Power saving mode
OFF
[F81] Security code
OFF
[F90] Setting of all functions
OFF
[F97] Copy function
OFF
[F98] Check of output
Normal
[F99] Reset to the default setting
OFF
8 Other Settings
•
Peak/bottom value display
The maximum (minimum) pressure when the power is supplied is
detected and updated.
•
Zero clear function
The displayed value can be adjusted to zero if the measured pressure
is within
±
7%F.S (
±
3.5% F.S. for compound pressure) of the zero point
•
Key-lock function
The key-lock function is used to prevent errors occurring due to
unintentional changes of the set values.
For further details refer to the operation manual on the SMC website
(URL:
https://www.smcworld.com
).
9 How to Order
Refer to the operation manual on the SMC website (URL:
https://www.smcworld.com
) for How to order information.
10 Outline Dimensions
Refer to the operation manual or catalogue on the SMC website (URL:
https://www.smcworld.com
) for Outline Dimensions.