SMC Networks ISE40A Instruction Manual Download Page 2

 Z_ISE40A-TF2Z052EN

 

Page 2 of 3 

 

4 Installation (continued) 

4.3.2 Connection using One-touch fitting 

1.  Cut the tube end perpendicular. 
2.  Hold  the  tube  and  insert  it  into  the  One-touch  fitting  slowly  until  it 

bottoms out. 

 

  Allow  sufficient  tube  length  to  prevent  twist  and  tensile  or  moment 

loads from being applied to the fitting or tube. 

  When  using  a  tube  manufactured  by  a  company  other  than  SMC, 

check that its outside diameter tolerance satisfies the following values: 
1)  Nylon tube: ±0.1 mm maximum 
2)  Soft nylon tube: ±0.1 mm maximum 
3)  Polyurethane tube: +0.15 mm / -2 mm maximum 

 

4.4  Vent Tube attachment 

  When the product is used in a place where water and dust splashes 

may occur, insert a tube into the atmospheric vent port, and route the 
other end of the tube to a safe place away from water and dust. 

 

  Insert the tube into the atmospheric vent port until it bottoms out. 

SMC TU0425 (polyurethane, O.D 

φ

4, I.D 

φ

2.5) is a suitable tubing. 

4.5  Lubrication 

Caution 

  SMC products have been lubricated for life at manufacture, and do not 

require lubrication in service. 

  If a lubricant is used in the system, use turbine oil Class 1 (no additive), 

ISO VG32. Once lubricant is used in the system, lubrication must be 
continued because the original lubricant applied during manufacturing 
will be washed away. 

 

5 Wiring 

5.1  Wiring connections 

  Connections should be made with the power supply turned off.

 

 

  Use  a  separate  route  for  the  product  wiring  and  any  power  or  high 

voltage wiring. Otherwise, malfunction may result due to noise. 

  If a commercially available switching power supply is used, be sure to 

ground the frame ground (FG) terminal. If the switching power supply is 
connected for use, switching noise will be superimposed and it will not 
be able to meet the product specifications. In that case, insert a noise 
filter  such  as  a  line  noise  filter/ferrite  between  the  switching  power 
supplies or change the switching power supply to a series power supply. 

  Tighten the connector by hand. 

 

DC (+) 

DC (-) 

OUT 

 

 

6 Pressure Setting 

6.1  Measurement mode 

The measurement mode is the condition where the pressure is detected 
and displayed, and the switch function is operating. 
This is the basic mode, and other modes should be selected for setting 
changes and other function settings. 

 

Setting the ON and OFF points of the Pressure switch. 

  Operation

 

When the pressure exceeds the set point, the Pressure switch will be 
turned ON. 
When the pressure falls below the set point by the amount of hysteresis 
or more, the Pressure switch will be turned OFF. 
The default setting of the output set value is the central value between 
the  atmospheric  pressure  and  the  upper  limit  of  the  rated  pressure 
range. 
If this condition, shown below, is acceptable, then keep these settings. 

 

 

 

 

 

 

 
 

6.2  Operation 

[Hysteresis mode] 

1, Press the 

 button once in measurement mode. 

 

2, [P_1] or [n_1] and the set value are displayed in turn. 

 

 
3, Press the 

 or 

 button to change the set value. 

The 

  button is to increase and the 

 button is to decrease. 

 

  Press  the 

  button  once  to  increase  by  one  digit,  and  press  it 

continuously to keep increasing the set value. 

 

 

6 Pressure Setting (continued) 

Press  the 

 button  once  to  decrease  by  one  digit,  and  press  it 

continuously to keep decreasing the set value. 

 

4, Press the 

 button to finish the setting. 

For models with 2 outputs, [P_2] or [n_2] will be displayed. Set as 
above. 

The Pressure switch operates within a set pressure range (from P1L to 
P1H) during window comparator  

mode. Set P1L (switch lower limit) and P1H (switch upper limit) with the 
setting procedure above. 

(When reversed output is selected, [n1L] and [n1H] are displayed.) 

 

Zero clear of Display 

The display is reset to zero when the 

 and 

 buttons are pressed 

simultaneously for 1 second. For the first operation, always perform zero 
clear with no pressure applied. 

 

 

 

 

 

 

 

 

 

 

 

7 Function Setting 

In measurement mode, press the 

 button for 2 seconds or longer to 

display [F 0]. Select to display the function to be changed, [F ## ]. 

Press the 

 button for 2 seconds or longer in function selection mode 

to return to measurement mode. 

 

 

*:  Some  functions  are  not  available  depending  on  part  number.  All  functions  are 

displayed  with  [F  ##]  followed  by  the  function  description.  If  a  function  is  not 
available, the function is displayed as [---]. 
 

7.1  Default Function settings 

At the time of shipment, the following settings are provided. 
If this condition is acceptable, then keep these settings. 
To change the settings, enter function selection mode. 
 

  [F 0] Unit

 selection function.

 

Unit specification 

Model 

Default setting 

Nil or M 

ISE40A 

MPa 

ZSE40A(F) 

kPa 

ISE40A 

psi 

ZSE40A(F) 

7 Function Setting (continued) 

  [F 1] 

Setting of OUT1

 

Item 

Description 

Default setting 

Output mode 

Select  hysteresis  mode  or 
window comparator mode. 

Hysteresis mode 

Reversed 
output 

Select reversed output. 

Normal output 

Pressure 
setting 

Set  the  ON  or  OFF  point  of 
the switch output 

ISE40A: 0.500 MPa 
ZSE40A: -50.7 kPa 
ZSE40AF: 50.0 kPa 

Hysteresis 

Set the  hysteresis  to  prevent 
chattering. 

ISE40A: 0.050 MPa 
ZSE40A: 5.1 kPa 
ZSE40AF: 5.0 kPa 

Display 
colour 

Select the display colour. 

ON: Green 
OFF: Red 

 

  [F 2] 

Setting of OUT2 is the same setting as [F 1] OUT1.

 

The display colour is linked to OUT1 and cannot be set for OUT2. 

 

 

Other parameter settings

 

Item 

Default setting 

[F 3] Response time 

2.5 ms 

[F 4] Auto-preset function 

Manual 

[F 5] Setting of analogue output / auto-shift input 

Analogue output 

[F 6] Fine adjustment of display value 

0% 

[F11] Display resolution 

1000-split 

[F80] Power saving mode 

OFF 

[F81] Security code 

OFF 

[F90] Setting of all functions 

OFF 

[F97] Copy function 

OFF 

[F98] Check of output 

Normal 

[F99] Reset to the default setting 

OFF 

 
 
 

8 Other Settings 

 

Peak/bottom value display 

The  maximum  (minimum)  pressure  when  the  power  is  supplied  is 
detected and updated.

 

 

Zero clear function 

The displayed value can be adjusted to zero if the measured pressure 
is within 

±

7%F.S (

±

3.5% F.S. for compound pressure) of the zero point 

 

Key-lock function 

The  key-lock  function  is  used  to  prevent  errors  occurring  due  to 
unintentional changes of the set values. 

 

For  further  details  refer  to  the  operation  manual  on  the  SMC  website 
(URL: 

https://www.smcworld.com

).

 

 

9 How to Order 

Refer  to  the  operation  manual  on  the  SMC  website  (URL: 

https://www.smcworld.com

) for How to order information. 

 

10 Outline Dimensions 

Refer to the operation manual or catalogue on the SMC website (URL: 

https://www.smcworld.com

) for Outline Dimensions. 

 

 

 

 

 

 

 

 