-11-
No.PS
※※
-OMJ0004-E
Pressure Setting
Operation
When the pressure exceeds the set value, the switch will be turned ON.
When the pressure falls below the set value by amount of hysteresis or more, the switch will be turned OFF.
As a default setting, the Pressure switch is set to turn ON when the pressure exceeds 0.35 MPa, and turn
OFF when it lowers 0.34 MPa.
If the operation shown below does not cause any problem, keep this setting.
<How to perform>
1. Press the
button in the measurement mode to display set values.
2. Press the
or
button to change the set value.
The
button is for increase and the
button is for decrease.
Press the
button once to increase by one figure and press it continuously to keep set figure
increased.
Press the
button once to decrease by one figure and press it continuously to keep set figure
decreased.
3. Press the
button to finish the setting.
For setting in window comparator mode, refer to "Pressure setting (in window comparator mode)"
on page