background image

 

-16- 

 

No.PS

※※

-OMJ0004-E 

 

 

 

 

Pressure setting (in window comparator mode) 

 

<How to perform> 

1. Press the 

  button in the measurement mode to display set value. 

 

 

2. Press the 

  or 

  button to change the set value. 

The 

  button is for increase and the 

  button is for decrease. 

 

Press the 

  button once to increase by one figure and press it continuously to keep 

set figure increased. 

 

 

Press the 

  button once to decrease by one figure and press it continuously to keep 

set figure decreased. 

 

 

3. Pressing the 

  button, set value for the second setting item is displayed. 

 

 

4. Press the 

  or 

  button to change the set value. 

 

5. Press the 

  button to finish the setting. 

 

Summary of Contents for ISE35

Page 1: ...No PS OMJ0004 E PRODUCT NAME Digital Pressure Switch MODEL Series Product Number ISE35...

Page 2: ...Identification and How to Order 8 Summary of Product parts 9 Mounting and Installation 10 Wiring 10 Pressure Setting 11 Setting of Function 12 Default setting 12 Other Settings 22 Maintenance 25 Trou...

Page 3: ...equipment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly T...

Page 4: ...the failure of the product 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 2 Vacuum pads are excl...

Page 5: ...ful fluids Fire malfunction or damage to the product can result Verify the specifications before use Do not operate in an atmosphere containing flammable or explosive gases Fire or an explosion can re...

Page 6: ...damage or malfunction of the Pressure switch Verify the specifications carefully before use Do not use the Pressure switch for compressed air containing plenty of condensed water Otherwise it can caus...

Page 7: ...e switch can be contaminated with noise or induced surge voltage from the power or high voltage line causing malfunction Lay the wires to the Pressure switch to a wire duct or in a protective tube oth...

Page 8: ...he Pressure switch Do not press the set buttons with a sharp pointed object It can cause damage to the set buttons Warm up for 20 to 30 minutes for the detection of low pressure The indication drifts...

Page 9: ...8 No PS OMJ0004 E Model Identification and How to Order Made to Order AR AW D Series Mounting kit is included An adapter O ring lock pin and two mounting screws are attached...

Page 10: ...mode and error code Four display modes can be selected display always in red or green only or switch from green to red or red to green linking to output button Increases the mode and ON OFF set value...

Page 11: ...duct or by using a series power supply instead of a switch mode power supply Connector Connecting Disconnecting When connecting the connector insert it straight onto the pin holding the lever and conn...

Page 12: ...ow does not cause any problem keep this setting How to perform 1 Press the button in the measurement mode to display set values 2 Press the or button to change the set value The button is for increase...

Page 13: ...page 15 1 s Operation mode Selects the mode to operate the Pressure switch page 15 Hysteresis mode Hysteresis page 17 0 01 MPa 1 psi Output type Sets the method to generate the switch output page 17...

Page 14: ...asurement mode The mode in which the pressure is detected and displayed and the switch function is operating This is the basic operating mode other modes should be selected for set point And other fun...

Page 15: ...to select the necessity of switch output 3 Keep pressing the button for 2 seconds or longer after selection is completed Then the setting is finished and the measurement mode returns 2 Indication col...

Page 16: ...elect the response time 3 Keep pressing the button for 2 seconds or longer after selection is completed Then the setting is finished and the measurement mode returns 4 Operation mode The switch operat...

Page 17: ...increase and the button is for decrease Press the button once to increase by one figure and press it continuously to keep set figure increased Press the button once to decrease by one figure and press...

Page 18: ...reased 3 Keep pressing the button for 2 seconds or longer after selection is completed Then the setting is finished and the measurement mode returns 6 Output type A desired output mode can be set free...

Page 19: ...s again only in the measurement mode The display in power saving mode is as shown on right figure 8 Secret code input The necessity of secret code input for key lock can be selected How to perform 1 K...

Page 20: ...19 No PS OMJ0004 E List of output mode If the point where the switch output is changed comes outside of set pressure range due to the change of set pressure hysteresis H is automatically compensated...

Page 21: ...ds or longer in the measurement mode After is indicated press button eight times Then and current setting appears in turn 2 Press the or button to select the indication mode 3 Keep pressing the button...

Page 22: ...a 0 01 Kgf cm2 0 1 bar 0 1 psi 1 How to perform 1 Press the button three times in the measurement mode and current setting appears in turn 2 Press the or button to select the indication unit 3 Press t...

Page 23: ...second or longer while the pressure is being held the maximum minimum value is initialized Zero clear A displayed value can be adjusted to zero when the pressure to be measured is within 10 F S of th...

Page 24: ...button to select unlocking of the key 3 When the button is pressed the input of secret code is asked For how to input the secret code refer to How to input and change the secret code on page 24 4 If i...

Page 25: ...nput and change the secret code Changed secret code is indicated 3 After check it is as desired press the button The measurement mode returns At this time if the or button is pressed changed secret co...

Page 26: ...accurate control wait until it has warmed up Approximate 20 to 30 minutes Mounting regulator Cut the power supply to the Pressure switch when assembling Also turn the set pressure of the regulator to...

Page 27: ...with SMC separately to obtain countermeasures Yes No The pressure switch does not operate normally Refer to reference No 1 The switch output is on Go to A The indicator light is on The indicator light...

Page 28: ...isplay is reversed Refer to reference No 7 The display is abnormal Refer to reference No 8 Refer to reference No 8 Refer to reference No 10 Refer to reference No 13 Refer to reference No 12 Refer to r...

Page 29: ...rform the pressure setting 2 Perform the functional setting Wrong setting Selection of without switch output Check if it can be set so that the switch output can be used Perform the functional setting...

Page 30: ...pper limit of the set pressure range 2 Check if moisture such as water droplets has entered the inside of the piping 1 Return the pressure to within the set pressure range 2 Take measures to prevent m...

Page 31: ...play is inverted Selection of unsuitable model Selection of wrong electrical entry Check the part number for the electrical entry Review the selected model Change of indication mode Check the selected...

Page 32: ...properly 2 Confirm that the Pressure switch is installed to the mounting adapter properly Correct the mounting conditions Product failure Replace the product 15 Noise Air leakage Check for air leakage...

Page 33: ...measurement mode 1 digit of the zero clear range varies with individual product differences Perform zero clear operation again after restoring the applied pressure to an atmospheric pressure conditio...

Page 34: ...s 80 mA load current Response time Chattering proof function 1 s 0 25 0 5 2 3 selectable Short circuit protection Provided Repeatability 1 F S Hysteresis Hysteresis mode Variable from 0 Window compara...

Page 35: ...34 No PS OMJ0004 E Dimensions...

Page 36: ...everal places July 2018 E Contents are added October 2019 4 14 1 Sotokanda Chiyoda ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL https www smcworld com Note Specifications are subj...

Reviews: