background image

1. Confirm the specifications.

Products represented in this catalog are designed for use in 
compressed air appllications only (including vacuum), unless 
otherwise indicated.
Do not use the product outside their design parameters.
Please contact SMC when using the products in applications 
other than compressed air (including vacuum).

4. Use clean air

If the compressed air supply is contaminated with chemicals, 
cynthetic materials, corrosive gas, etc., it may lead to break 
down or malfunction.

Selection

Mounting

Piping

Air Supply

Maintenance

Operating Environment

Warning

1. Instruction manual

Install the products and operate them only after reading the 
instruction manual carefully and understanding its contents. 
Also keep the manual where it can be referred to as 
necessary.

2. Securing the space for maintenance

When installing the products, please allow access for 
maintenance.

3. Tightening  torque

When installing the products, please follow the listed torque 
specifications.

Warning

1. Do not use in environments where the product 

is directly exposed to corrosive gases, 
chemicals, salt water, water or steam.

2. Do not expose the product to direct sunlight 

for an extended period of time.

3. Do not use in a place subject to heavy 

vibrations and/or shocks.

4. Do not mount the product in locations where it 

is exposed to radiant heat.

Warning

1. Maintenance procedures are outlined in the 

operation manual.

Not following proper procedures could cause the product to 
malfunction and could lead to damage to the equipment or 
machine.

2. Maintenance work

If handled improperly, compressed air can be dangerous.
Assembly, handling and repair of pneumatic systems should 
be performed by qualified personnel only.

3. Drain flushing

Remove drainage from air filters regularly. (Refer to the 
specifications.)

4. Shut-down before maintenance

Before attempting any kind of maintenance make sure the 
supply pressure is shut of and all residual air pressure is 
released from the system to be worked on.

5. Start-up after maintenance and inspection

Apply operating pressure and power to the equipment and 
check for proper operation and possible air leaks. If operation 
is abnormal, please verify product set-up parameters.

6. Do not make any modifications to be product.

Do not take the product apart.

Warning

1. Before piping

Make sure that all debris, cutting oil, dust, etc, are removed 
from the piping.

2. Wrapping of pipe tape

When screwing piping or fittings into ports, ensure that chips 
from the pipe threads or sealing material do not get inside the 
piping. Also, when the pipe tape is used, leave 1.5 to 2 thread 
ridges exposed at the end of the threads.

Caution

1. Operating fluid

Please consult with SMC when using the product in 
applications other than compressed air (including vacuum).
Regarding products for general fluid, please ask SMC about 
applicable fluids.

2. Install an air dryer, aftercooler, etc.

Excessive condensate in a compressed air system may cause 
valves and other pneumatic equipment to malfunction.
Installation of an air dryer, after cooler etc. is recommended.

3. Drain flushing

If condensate in the drain bowl is not emptied on a regular 
basis, the bowl will over flow and allow the condensate to 
enter the compressed air lines.
If the drain bowl is difficult to check and remove, it is 
recommended that a drain bowl with the auto-drain option be 
installed.
For compressed air quality, refer to “Air Preparation 
Equipment” catalog.

Warning

Common Precautions

Be sure to read before handling.
For detailed precautions on every series, refer to main text.

16-14-4

Summary of Contents for IS3000 Series

Page 1: ...ch load type With gasket Rc 1 4 NPT 1 4 Nil 02 N02 Port size How to Order IS3 00 Inductive load A Non inductive A Non inductive A IS3 Standard Micro load 125 AC 250 AC 30 DC 125 DC Load Circuit Rated voltage V IS3 10 N C Load resistance Light load Inductive load Motor load Load resistance N O N C N O N C N O N C N O N C N O 5 3 4 0 4 3 2 3 0 4 0 1 0 1 1 3 0 8 2 5 1 5 0 7 0 5 1 5 1 3 0 05 2 0 05 In...

Page 2: ...following 2 Please put the enclosed seal of LAMP LIGHTS WHEN PRESSURE RISES or LAMP GOES OUT WHEN PRESSURE RISES on the equipment where it is easy to see 1 Allow the space required for maintenance Otherwise maintenance or pressure adjust ment cannot be made since the adjusting screw is on the top of the body 2 Mounting is possible in either horizontal or vertical orientations 1 Turn the adjusting ...

Page 3: ...d experienced operators 3 Do not service machinery equipment or attempt to remove components until safety is confirmed 1 Inspection and maintenance of machinery equipment should only be performed once measures to prevent falling or runaway of the driver objects have been confirmed 2 When equipment is to be removed confirm the safety process as mentioned above Cut the supply pressure for this equip...

Page 4: ... qualified personnel only 3 Drain flushing Remove drainage from air filters regularly Refer to the specifications 4 Shut down before maintenance Before attempting any kind of maintenance make sure the supply pressure is shut of and all residual air pressure is released from the system to be worked on 5 Start up after maintenance and inspection Apply operating pressure and power to the equipment an...

Page 5: ... an international standard related to environmental management systems and environmental inspections While promoting environmentally friendly automation technology SMC is also making diligent efforts to preserve the environment Environmental management system ISO 14001 Sales coordination Production Make customers our first priority offering them reliable and friendly service Market research Produc...

Page 6: ...achinery Directive The Machinery Directive contains essential health and safety requirements for machinery as applied to industrial machines e g machine tools injection molding machines and automatic machines Pneumatic equipment is not specified in Machinery Directive However the use of SMC products that are certified as conforming to EN Standards allows customers to simplify preparation work of t...

Page 7: ...ation OSHA SMC was tested for compliance with CSA Standards and UL Standards at the same time and was approved for compliance with the two Standards The above CSA NRTL C logo is described on a product label in order to indicate that the product is approved by CSA and UL Standards TSSA MCCR Registration Products TSSA is the regulation in Ontario State Canada The products that the operating pressure...

Page 8: ...6 COLOMBIA Distributor Airmatic Ltda Calle 18 69 05 Apart Aereo 081045 Santa Fe de Bogotá Colombia TEL 1 424 9240 FAX 1 424 9260 U K SMC Pneumatics U K Ltd Vincent Avenue Crownhill Milton Keynes MK8 0AN Backinghamshire U K TEL 01908 563888 FAX 01908 561185 GERMANY SMC Pneumatik GmbH Boschring 13 15 D 63329 Egelsbach Germany TEL 06103 4020 FAX 06103 402139 ITALY SMC Italia S p A Via Garibaldi 62 I ...

Page 9: ...Sylvia Park Road Mt Wellington Auckland New Zealand TEL 09 573 7007 FAX 09 573 7002 TAIWAN SMC Pneumatics Taiwan Co Ltd 17 Lane 205 Nansan Rd Sec 2 Luzhu Hsiang Taoyuan Hsien TAIWAN TEL 03 322 3443 FAX 03 322 3387 HONG KONG SMC Pneumatics Hong Kong Ltd 29 F Clifford Centre 778 784 Cheung Sha Wan Road Lai Chi Kok Kowloon Hong Kong TEL 2744 0121 FAX 2785 1314 SINGAPORE SMC Pneumatics S E A Pte Ltd 8...

Reviews: