2. Transportation and Installation
2 - 6
2.2
Cautions about Reinstallation
Caution
No one but someone who has enough knowledge about the equipment and incidental
devices should reinstall in another place. And following instructions must be executed.
If you move the product and reinstall it into another place after some operations (including trial running),
instructions that are not only following ones but also all of those in the chapter 2 should be followed.
Disassembly of the power cable
Cut off the power source when you disassemble the power cable.
Disassembly of the air piping
Remove the s
eal tape completely after detaching the piping. Remained tape will cau
se imperfect
cooling and failure by entering into the body of the equipment.
Compressed air residual pressure release procedure
1. Even while the dryer is removed, only when compressed air is needed, open the bypass piping valve.
2. Close the compressed air inlet and outlet valve.
3. Remove the right side panel.
4.
Open the residual pressure release cock of auto drain tube, and release compressed air pressure left inside of
the equipment. Refer to the method to clean the auto drain strainer in ”Chapter 4 Periodical maintenance” for
detail.
Warning
No one but qualified personnel should do the electric wiring.
Cut off the power supply for safety before the wiring. Do not work under energized
condition.
Warning
No one but qualified personnel should do the air piping.
Separate the compressor from the product for safety before removing the piping. Do not
remove any piping when there is remaining compressed air pressure inside of it.
Residual pressure
release cock