IDX-OM-V024
Chapter
11
Option T
IDFB60/70/80/90 Series
11.1
Safety instructions for use
11-1
Chapter 11
Option T
Option T has terminal block for the output of operation and error signals and remote control.
11.1 Safety instructions for use
Refer to the instructions below when handling the product.
11.2 Operation / Error signal output
- Operation mode signal (Contact output)
Operation signal - - - During operation: contact "close"
Error signal - - - During error: contact "close"
- Contact capacity
Rated load voltage 240 VAC or less / 24 VDC or less
Maximum load current 5A (resistance load) / 2A (inductive load)
Minimum applicable load 20 VDC 3mA
All electrical work must be carried out in a safe manner by a qualified person in compliance
with applicable national regulations.
- Be sure
to shut off the user’s power supply. Wiring with the product energized is strictly
prohibited.
- Ensure a stable power supply with no surge.
- Mount the correct electric leakage breaker of the specified leakage capacity and load
capacity to prevent electric shock and burning of the compressor motor.
- Use a power supply suitable for the specifications of the product.
- The equipment should be grounded for safety. Earth leakage breaker does not operate
correctly without grounding.
- Do not modify the internal electrical wiring of the product.
WARNING
Summary of Contents for IDFB60-23-C
Page 36: ...IDX OM V024 Chapter 7 Documents 7 5 Air Refrigerant Circuit IDFB60 70 80 90 Series 7 6 ...
Page 50: ......
Page 51: ......