IDX-OM-V024
Chapter
10
Option R
IDFB60/70/80/90 Series
10.1
Safety instructions for use
10-1
Chapter 10
Option R
Option R is equipped with an earth leakage breaker (GFCI). This is to shut off the power supply when
over current or leakage current is applied to the air dryer.
10.1 Safety instructions for use
Refer to the instructions below when handling the product.
10.2 Earth leakage breaker specification
Models
Item
IDFB60-23-R
IDFB70-23-R
IDFB80-23-R
IDFB90-23-R
Rated current (A)
10
15
20
30
Sensitivity current (mA)
30
All electrical work must be carried out in a safe manner by a qualified person in compliance
with applicable national regulations.
- Be sure to shut off the
user’s power supply. Wiring with the product energized is strictly
prohibited.
- Ensure a stable power supply with no surge.
- Use a power supply suitable for the specifications of the product.
- The equipment should be grounded for safety.
Earth leakage breaker does not operate correctly without grounding.
- Do not connect the earth to a water pipe, a gas pipe, or a lightening rod.
- Do not plug too many leads into a single socket. That causes exothermic heat or fire.
- Do not modify the internal electrical wiring of the product.
WARNING