background image

Maintenance

Caution

1 . In periodical inspections, check the following items 

and replace the parts if necessary.

a) Scratches, gouges, abrasion, corrosion
b) Air leakage
c) Twisting, crushing, and turning of connected tubes
d) Hardening, deterioration, and softening of connected tubes
e) Loosening of nozzles

2.  When removing the product, first stop the pressure 

supply, exhaust compressed air in the piping, and 
check the condition of atmospheric release.

3.  Do not disassemble or remodel the body of the product.

Handling

Warning

1.  Air pressure may cause the nozzle to fly off during operation if it 

is not properly tightened. To prevent this, be sure to check the 
nozzle for loosening by pulling on it with your hands before use.

2.  Be sure to wear protective eyewear when operating the 

product to protect your eyes from scattering debris.

3.  Do not direct the tip of the nozzle at the face or other 

parts of a human body. It may cause danger to personnel.

4.  Do not use the product to clean or remove toxic 

substances or chemicals.

5.  Do not drop, step on, or hit the product. It may 

cause damage to the product.

6.  Do not use the product to disturb public order or 

public hygiene.

7. This product is not a toy.

8. After blowing, make sure to hang the product on a hook, etc.

If leaving the product in a dusty place, particles will enter the 
product and may result in a malfunction.

Hook

9.  When the blow gun is used or stored, confirm that no 

twisting, turning, or tensile force or moment load is 
applied to the port or tube. This may cause fittings to 
fracture or tubes to be crushed, burst, or come loose.

Caution

1.  Pressurizing the air blow discharge port may result 

in the breakage of the product.

2.  The blow adjusting range 4 provides the maximum blow. Rotating 

the adjuster more than 4 may result in the breakage of the product.

Lubrication

Warning

1. Do not lubricate the product.

It may contaminate or damage the target object.

Air Supply

Warning

1. Use clean air.

Do not use compressed air that contains chemicals, synthetic 
oils that include organic solvents, salt, corrosive gases, etc., 
as it can cause damage or malfunction.

Caution

1. Install an air filter.

Install an air filter upstream near the blow gun. Select an air 
filter with a filtration size of 5 

μ

m or smaller.

2.  Take measures to ensure air quality, such as by 

installing an aftercooler, air dryer, or water separator.

Compressed air that contains a large amount of drainage can 
cause the malfunction of the blow gun and contaminate or 
damage the target object. Therefore, take appropriate 
measures to ensure air quality, such as by providing an 
aftercooler, air dryer, or water separator.

Operating Environment

Warning

1.  Do not use in an atmosphere where corrosive 

gases, chemicals, sea water, water, or water steam 
are present. Do not use in cases where there is 
direct contact with any of the above.

2.  Do not expose the product to direct sunlight for an 

extended period of time.

3.  Do not use in locations where radiated heat will be 

received from nearby heat sources.

4.  Do not use in an environment where static electricity 

is a problem. It may result in system failure or 
malfunction. Please contact SMC for use in such an 
environment.

5.  Do not use in an environment where spatters are 

generated. Spattering may result in a fire hazard. 
Please contact SMC for use in such an environment.

6.  Do not use in an environment where the product is 

exposed to cutting oil, lubricating oil, or coolant oil. 
Please contact SMC for use in such an environment.

Be sure to read this before handling the products. Refer to the back cover for safety 
instructions. For other precautions, refer to the “Handling Precautions for SMC 
Products” and the “Operation Manual” on the SMC website: https://www.smcworld.com

IBG 

Series

Specifi c Product Precautions 2

6

Summary of Contents for IBG Series

Page 1: ...consumption Continuous blow air consumption IBG1 Existing blow gun Air consumption 6 3 L Peak pressure 1 According to blow requirements 2 Pressure 0 5 MPa Based on SMC s specific testing conditions 87...

Page 2: ...ak pressure adjustment is available Peak pressure MPa Number of needle rotations 0 0 1 0 2 0 3 4 3 2 1 0 Peak pressure and the number of needle rotations Supply pressure 0 5 MPa As the tank is built i...

Page 3: ...e long nozzle and fitting set 3 The silencer and long nozzle can be used together Part number for ordering a silencer alone is IBG1 12S Impact Blow Gun IBG Series How to Order Specifications IBG1 0 Mo...

Page 4: ...Without adjuster IBG11 With adjuster Dimensions Symbol Type Nozzle length Nozzle part no A mm Weight g 01 Long nozzle 50 mm IBG1 12 10 50 57 35 02 100 mm IBG1 12 10 100 107 40 03 150 mm IBG1 12 10 15...

Page 5: ...the nozzle is inserted down to the marking xInsert the nozzle until it touches the fitting body Then mark a line on the nozzle at the edge of the union nut bUsing the tightening tool tighten the union...

Page 6: ...crushed burst or come loose Prior to Use Warning As the pressure of the air blow is quite powerful do not aim the product at another person during operation It may cause danger to personnel Additiona...

Page 7: ...he breakage of the product Lubrication Warning 1 Do not lubricate the product It may contaminate or damage the target object Air Supply Warning 1 Use clean air Do not use compressed air that contains...

Page 8: ...tallation on equipment in conjunction with atomic energy railways air navigation space shipping vehicles military medical treatment combustion and recreation or equipment in contact with food and beve...