  Safety Instructions 

These safety instructions are intended to prevent hazardous situations and/or equipment damage. 
These instructions are categorized into three groups, "Caution", "Warning" and "Danger" depending on the 
level of hazard and damage, and the degree of emergency. 
They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC), 
Japan Industrial Standards (JIS)*1) and other safety regulations*2). 

*1) ISO 4414: Pneumatic fluid power -- General rules relating to systems 

 

  ISO 4413: Hydraulic fluid power -- General rules relating to systems 

 

  IEC 60204-1: Safety of machinery -- Electrical equipment of machines (Part 1: General requirements) 

 

  ISO 10218-1992: Manipulating industrial robots -- Safety 

 

  JIS B 8370: General rules for pneumatic equipment. 

 

  JIS B 8361: General rules for hydraulic equipment.   

 

  JIS B 9960-1: Safety of machinery 

– Electrical equipment for machines. (Part 1: General requirements) < Example of   

required specifications > 

 

  JIS B 8433-1993: Manipulating industrial robots - Safety. etc. 

*2) Labor Safety and Sanitation Law, etc. 

 
 

Caution

 

Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or 
moderate injury.

 

 
 

Warning

 

Warning  indicates  a  hazard  with  a  medium  level  of  risk  which,  if  not  avoided,  could  result  in 
death or serious injury.

 

 
 

Danger

 

Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or 
serious injury.

 

 

Warning

 

The compatibility of the product is the responsibility of the person who designs the equipment or 
decides its specifications. 

Since the product specified here is used under various operating conditions, its compatibility with specific 
equipment must be decided by the person who designs the equipment or decides its specifications based 
on necessary analysis and test results.   
The expected performance and safety assurance of the equipment will be the responsibility of the person 
who has determined its compatibility with the product.   
This person should also continuously review all specifications of the product referring to its latest catalog 
information,  with  a  view  to  giving  due  consideration  to  any  possibility  of  equipment  failure  when 
configuring the equipment. 

Only personnel with appropriate training should operate machinery and equipment. 

The product specified here may become unsafe if handled incorrectly. 
The assembly, operation and maintenance of machines or equipment must be performed by an operator 
who is appropriately trained and experienced. 

Do not service or attempt to remove product and machinery/equipment until safety is confirmed. 

1.The inspection and maintenance of machinery/equipment should only be performed after measures to 

prevent dropping of driven objects or run-away of machinery/equipment have been confirmed. 

2.When  the  product  is  to  be  removed,  confirm  that  the  safety  measures  as  mentioned  above  are 

implemented and the power from any appropriate source is cut, and read and understand the specific 
product precautions of all relevant products carefully. 

3.Before  machinery/equipment  is  restarted,  take  measures  to  prevent  unexpected  operation  and 

malfunction. 

Contact SMC beforehand and take special consideration of safety measures if the product is to be 
used in any of the following conditions. 

1.Conditions and environments outside of the given specifications, or use outdoors or in a location 

  exposed to direct sunlight. 

2.Installation on equipment in conjunction with atomic energy, railways, air navigation, space, shipping, 

vehicles, military, medical treatment, combustion and recreation, or equipment in contact with food and 
beverages, emergency stop circuits, clutch and brake circuits in press applications, safety equipment or 
other applications unsuitable for the standard specifications described in the product catalog. 

3.An application which could have negative effects on people, property, or animals requiring special safety 

analysis. 

4.Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a 

mechanical protective function, and periodical checks to confirm proper operation. 

    

 

Summary of Contents for FGFS1 Series

Page 1: ...he model number of used bag filter Read and understand the Operation Manual before installing and operating the product In particular before restarting the product ensure that safety measures are take...

Page 2: ...ications 6 1 How to order 6 2 Specifications 6 4 Circuit 6 5 Assembly Installation and piping 7 1 Assembly 7 1 1 Mounting of feet 1 2 Mounting of pressure sensor 2 Installation 7 3 Piping 8 6 Maintena...

Page 3: ...ity with the product This person should also continuously review all specifications of the product referring to its latest catalog information with a view to giving due consideration to any possibilit...

Page 4: ...cessary parts will be provided This limited warranty applies only to SMC product independently and not to any other damage incurred due to the failure of the product Prior to using SMC products please...

Page 5: ...nt 450mm or more Around the band Space to remove the band for replacing the element 50mm or more for the upper space of the band This product is classed as a filter for liquid However the product may...

Page 6: ...ce the element with a new one when the replacement timing has come Element replacement timing When pressure drop reaches 0 1 MPa Element replacement Maintenance should be performed according to the pr...

Page 7: ...model number on the model number label for ordering parts Select the part number which is suitable for specified model number Note 2 is the space for the symbol of filtration Check the element part nu...

Page 8: ...ant aqueous type oil based Alkalescent cleaning agent industrial water Not applicable for gas Fluids which corrode det eriorate or swell the filter and element material cannot be used Maximum operatin...

Page 9: ...5 3 Tighten the bolts until the feet are fixed to the case so that they do not become loose Be careful not to drop or knock over the body case 1 2 Mounting the pressure gauges Mount the pressure gauge...

Page 10: ...770 is the space for the symbol of filtration Check the element part number on the model number label before ordering e g Nominal filtration 5 m EJ501S 005 For the replacement of element Replace the e...

Page 11: ...5 Caution Be careful not to burn your skin if the temperature is high 4 How to mount the element Pull the cloth handle of a new element to the center Squeeze the element brim to insert the element int...

Page 12: ...ring Part number for replacement FGF KT01 FGFS1 Seal material NBR FGF KT02 FGFL1 Seal material FKM Replacement of O ring Replace O ring following steps 1 and 5 to 7 of P8 1 2 Element replacement proc...

Page 13: ...RL http www smcworld com Note Specifications are subject to change without prior notice and any obligation on the part of the manufacturer 2020 SMC Corporation All Rights Reserved Revision history Rev...