Troubleshooting table
Trouble No.1
Trouble
Possible cause
Investigation method of cause
Remedy
Only the
solenoid valve
LED turn on.
Solenoid valve failure.
Check the troubleshooting for the solenoid
valve.
Same as left.
Trouble No.2
Trouble
Possible cause
Investigation method of cause
Remedy
The outputs
that are
beyond the
maximum
point number
do not operate.
Inadequate total
number of outputs
from the solenoid
valves and Output
block connected with
the SI unit.
Check if the total number of outputs is 32 or
less (24 for the solenoid valve VQC series).
Delete unused extra outputs
from the manifold, and
ensure there are 32 outputs
or less (24 outputs or less for
the VQC series solenoid
valve).