SMC Networks EX250-SDN1-X102 Installation & Maintenance Manual Download Page 1

Installation & Maintenance Manual

SI unit - DeviceNet compatible

Type EX250-SDN1/EX250-SDN1-X102

The unit and this manual contain essential information
to protect users and others from possible injury and property
damage and to ensure correct handling.
Please confirm that you fully understand the meaning of the
following messages (signs) before reading the text, and always
follow the instructions.
Please read the Installation & Maintenance Manual for related
apparatus and understand it before operating the actuator.

Read this manual and follow the instructions.
Signal words such as WARNING, CAUTION and NOTE,
will be followed by important safety information that must
be reviewed carefully.

IMPORTANT MESSAGES

Indicates a potentially hazardous situation
which could result in death or serious injury
if you do not follow instructions.

Provides you helpful information.

Do not disassemble, modify (including change of printed
circuit board) or repair.

An injury or failure can result.

Do not operate outside of the specification range.

Fire, malfunction or damage can result.
Please use it after confirming the specification.

Do not use the product in environments with possible
presence of flammable, explosive or corrosion gas.

Otherwise fire, explosion or corrosion can result.
The product is not designed to be explosion proof.

.Connect wires and cables correctly.

.Do not connect wires while the power is on.

.Do not lay wires or cables with the same wiring route as a power line or

high-voltage line.

.Verify the insulation of the wiring.

.Take proper measures against noise such as a noise filter when the

product is incorporated in equipment or devices.

.Select an operation environment according to enclosure(IP67).

.Take sufficient shielding measures when installing the product at the

following place.
(1)A place where a noise due to static electricity etc. is generated
(2)A place of high electric field strength
(3)A place possibly exposed to radioactivity
(4)A place near power cable

.Do not use the product nearby a place where an electric surge is

generated.

.Use the product equipped with a surge absorber when a surge-

generating load such as a solenoid valve is driven directly.

.Prevent foreign matter such as remnant of wires from entering the

product.

.Do not expose the product to vibration and impact.

.Keep the specified ambient temperature range (+5 to +45

).

.Do not expose the product to heat radiation from a heat source

located nearby.

.Use a precision screw driver with small flat blade when setting

rotary switch and DIP switch.

.Perform maintenance and check at regular intervals.

.Perform a proper functional check.

.Do not clean the product with chemicals such as benzine and

thinner.

Specification

Safety Instructions

Indicates a potentially hazardous situation
which if not avoided, may result in minor
injury or moderate injury.

Do not apply voltages exceeding 250V between a lead
wire and a metal fitting.

Pay attention to perform an insulation test because it could
damage the insulation of the lead wire and cause failure.

These instructions must be followed when using the
product in an interlocking circuit:

.Provide double interlocking through another system

such as mechanical protection.

.Check the product regularly to ensure proper operation.

Otherwise malfunction can cause an accident.

These instructions must be followed when performing
maintenance work:

.Turn off the power supply
.Stop the air supply, exhaust the residual pressure and verify

that the air is released before performing maintenance work.

Otherwise it can cause injury.

Perform a proper functional check after completing
maintenance work.

Stop operation when an abnormality is observed or the product is
not working properly.
Safety cannot be assured due to unexpected malfunctions.

NOTE

The direct-current power supply should be a UL authorized power
supply.
1.Limited voltage current circuit in accordance with UL508

A circuit to which power is supplied by the secondary coil of
a transformer that meets the following conditions.

.Max. voltage(with no load): less than 30Vrms(42.4V peak)

.Max. current:(1)less than 8A(including when short circuited)

(2)limited by circuit protector (such as fuse) with

the following ratings

2.UL1310 compatible class 2 power supply unit or circuit of

max. 30Vrms (42.4V peak) or less using a UL1585 compatible
class 2 transformer as power supply. (Class 2 circuit)

Follow the instructions given below when handling the product.
Failure to follow instructions may damage the unit.

.Operate the product within the specified voltage range.

.Reserve a space around the unit for maintenance.

.Do not remove labels.

.Do not drop, hit or apply excessive shock to the product.

.Do not bend or apply tensile force to cables, or apply a force by placing

a heavy load on them.

No load voltage (V peak)

0 to 20 [V]

20 to 30 [V]

Max.current rating (A)

5.0

100 / peak voltage

Item

Specification

Operating ambient temp.

+5 to +45

Operating ambient humidity

35 to 85% RH (No dew condensation)

Storage ambient temp.

-20 to +60

Vibration proof

10 to 57Hz 0.35mm (Constant amplitude)
57 to 150Hz 50m/s

2

(Constant acceleration)

Impact proof

150m/s

2

(peak), 11ms three times in each

direction ± X, Y and Z.

Noise immunity

Normal mode : ±1500V Pulse duration 1us
Common mode : ±1500V Pulse duration 1us
Radiation : ±1000V Pulse duration 1us

Withstand voltage

500V AC for 1min.

Insulation resistance

500V DC min10M ohm

Operating environment

No corrosive gas and no dust

General specification

Item

Specification

Applicable system

DeviceNet Release 2.0

Power voltage
range
Current
consumption

Power for SI unit
Current consumption

11 to 25V DC
100mA or less

Power for Input
BlockCurrent
consumption

19.2 to 28.8V DC
Depending on the number of Input
Block stations and sensor
specifications. Max 1A or less

Power for solenoid
valve
Current consumption

21.6 to 26.4V DC (Power reduction
alarm occurs at approx. 19V DC.)
Depending on number of Solenoid
valve station and specifications Max
2.5A or less

Solenoid valve
connection spec.

Output type

P-ch MOS-FET Open drain type

Connection load

Solenoid valve with protection circuit for
24V DC and 1.5W or less surge
voltage. (made by SMC)

Insulation type

Opto coupler type

Residual voltage

0.3V DC or less

N

e

tw

o

rk

c

o

n

n

e

c

ti

o

n

s

p

e

c

.

MAC ID setting range

0 to 63
(Set by DIP / retain address information
when setting power is shut off via
network.)

Baud Rate
(Transmission speed)

500kbps, 250kbps, 125kbps
(Set by DIP / hold address information
when setting power is shut off via
network.)

Slave (branch station) type

Group 2 only server

Connection type

T branch type, Multi drop type

Device type

27

Product code

2401

Revision

Refer to EDS file

Vendor ID

7

Consumed connection size
(Receiving byte)

4 (Polled I/O connection : Occupy 4 byte)

Produced connection size
(Sending byte)

4
(Polled I/O connection
: Occupy 4 byte)

Correspond message

Polled command (I/O message),
Explicit message.

Electrical and network

Names and Functions of Individual Parts

Output equipment
connector

Indication and address
setting panel

Communication

connector

Ground terminal

Power supply connector

for output equipment,

SI unit and Input block

Input block
connector

Body

.

Communication connector
To send and receive communication signals through DeviceNet line.

.

Power supply connector for output equipment, SI unit and Input block
To supply power to the output equipment such as a solenoid
valve, and output block, SI unit and Input block.

.

Output equipment connector
To connect the output equipment such as a solenoid valve
and output block.

.

Input block connector
To connect the Input block.

.

Indication and address setting panel
To provide LED's to indicate the condition of the unit,
and the setting of address and HOLD/CLEAR functions.

.

Ground terminal
To be connected to the ground.

Outline with Dimensions (in mm)

6

4

.4

7

4

.9

5

9

.8

63

Safety Instructions (continue)

Model Indication Method

EX250 - SDN1 (X102)

SI Unit for DeviceNet

SI Unit Series

Special specification
  X102 :

Without function to monitor supply

 

voltage for solenoid valve.

 

Number of occupied bytes is 6 for

 

input and 4 for output.

2404

Part No.

EX250-SDN1

EX250-SDN1-X102

6
(Polled I/O connection
: Occupy 6 byte)

EX250-TFI73GB-A