-21-
No.EX##-OMU0020-A
4.1.3. Modules
The SI unit can consists of the following modules.
Table. 4-2 Overview of modules for the SI unit
Module name
Occupied bytes
Allowable slot
Note
Diagnostics type 1
4 bytes (IN)
1
Refer to
Diagnostics type 2
4 bytes (IN)
1
Refer to
Valves (16 coils)
2 bytes (OUT)
1…2
Refer to
Valves (32 coils)
4 bytes (OUT)
1…2
EX245-DX1-X36
2 bytes (IN)
2…10
Refer to
EX245-DY1-X37
1 byte (OUT)
2…10
Refer to
EX245-DY2-X37
1 byte (OUT)
2…10
Option
EX245-AX2-X38
3 bytes (IN)
1 byte (OUT)
2…10
Option
Caution
・
When you operate the digital input module(EX245-DX1) and the digital output
module(EX245-DY1), select the digital input module(EX245-DX1-X36) and the digital output
module(EX245-DY1-X37) as the configuration module on the master software (Siemens
"STEP7", etc.).
・
The modules "
EX245-DY2-X37
" and "
EX245-AX2-X38
" are options which can be enabled to use
a special module.