background image

33.4

(36)

(11.5)

34.4

94.5

34.4

94.5

33.4

Position indicator LED

Position indicator LED

Power supply connector

Communication connector

Screw terminal block

Standards
Weight

Accessory

EX140-SDN1

EX140-SMJ1

EX140-SCS1
EX140-SCS2

EX140-SSL1
EX140-SSL2

EX140-SUW1

EX140-SUH1

SI Unit Specifications

Model 

Communication speed

Configuration file 

Note 2)

Terminating resistor
For unit 
For valve

Output type

Number of outputs

Load

Enclosure

Operating humidity range
Withstand voltage
Insulation resistance

Applicable 
system

Protocol

Version 

Note 1)

Internal current consumption (Unit)

Fail safe

Operating temperature
range

I/O occupation area 
(Inputs/Outputs)

Communication

Output

Environment

Power supply 
voltage

DeviceNet™

Release 2.0

125 k/250 k/500 kbps

11 to 25 VDC

16 outputs

Solenoid valve with surge voltage suppressor 24 VDC, 2.1 W or less (SMC)

24 VDC+10%/–5%

EDS file

0/16

Hold/Clear

(Switch setting)

CE marking

Communication connector 1 pc.,

Power supply connector 1 pc.

32/32

(1 station, remote

I/O stations)

CC-Link

OMRON Corp.:

CompoBus/S

Panasonic Industrial 

Devices SUNX Co., Ltd.:

S-Link

NKE Corp.:

Fieldbus System

NKE Corp.:

Fieldbus H System

Ver. 1.10

156 k/625 kbps

2.5 M/5 M/10 Mbps

750 kbps

28.5 kbps

28.5 kbps

29.4 kbps

SCS1: 0/16

SCS2: 0/8

SSL1: 0/16

SSL2: 0/8

Not provided

0/16

15 to 30 VDC

14 to 26.4 VDC

24 VDC+10%/–5%

(Common

power supply)

100 mA or less

Sink/NPN (Positive common)

IP20

35 to 85%RH (With no condensation)

1500 VAC for 1 min. between whole external terminal and enclosure

2 M

 or more (500 VDC) between whole external terminal and enclosure

80 g or less

SCS1/SSL1: 16 outputs

SCS2/SSL2: 8 outputs

0 to +55

°

C (Valve 8 points ON)

0 to +50

°

C (Valve 16 points ON)

16 outputs

Clear

24 VDC

±

10%

(Common power supply)

Note 1) Please note that the version is subject to change.
Note 2) Each file can be downloaded from SMC website (http://www.smcworld.com).
Note 3) For detailed specifications other than the above, refer to the operation manual that can be downloaded from SMC website (http://www.smcworld.com).

SI Unit Dimensions/Parts Description

EX140-SMJ1, SCS

, SSL

, SUW1, SUH1

EX140-SDN1

For Output  

EX140 

Series

785

EX12

EX140

EX180

EX260

EX250

EX600

EX500

EX510

PCA

EX

EX140

Summary of Contents for EX120-SCM1

Page 1: ...anasonic Industrial Devices SUNX Co Ltd S LINK 8 outputs NKE Corp Fieldbus System NKE Corp Fieldbus H System CompoNet NPN Positive common CompoNet PNP Negative common CE compliant SV1000 2000 3000 400...

Page 2: ...Download from SMC s website 0 16 Not provided Note For details about the communication speed or each setting instruction check the operation manual that can be downloaded from SMC website Note Commun...

Page 3: ...ng bracket MIL connector 20 pins socket Position indicator LED Terminal block cover Screw terminal block DIN rail mounting bracket MIL connector 20 pins socket Position indicator LED Terminal block co...

Page 4: ...tor Straight type power supply connector This connector is supplied at shipment EX9 CP2 Communication connector Terminal block connector for round cable VCTF Use this connector for the VCTF cable The...

Page 5: ...outputs while DN1 X26 has 0 inputs and 16 outputs Enclosure IP65 EX123 EX124 IP67 EX126 Maximum 16 outputs How to Order SI Unit Unit specifications SL1 EX12 S U 3 Communication protocol U D Mount a un...

Page 6: ...pped How to Order Options Fuse for replacement A fuse for replacement used for EX126D SMJ1 EX9 FU20 Applicable model Rated current EX126D SMJ1 2 0 A Dripproof plug assembly Use for the unused wiring e...

Page 7: ...X124 4 x G1 2 Wiring entry Housing cover diagram Position indicator LED Screw terminal block Housing bottom diagram Power supply fuse for solenoid valve Power supply fuse for communication Note The ho...

Page 8: ...sonic Industrial Devices SUNX Co Ltd S LINK 16 outputs Panasonic Industrial Devices SUNX Co Ltd S LINK 8 outputs NKE Corp Fieldbus System NKE Corp Fieldbus H System CE compliant Note Please consult SM...

Page 9: ...tion remote I O stations CC Link OMRON Corp CompoBus S Panasonic Industrial Devices SUNX Co Ltd S Link NKE Corp Fieldbus System NKE Corp Fieldbus H System Ver 1 10 156 k 625 kbps 2 5 M 5 M 10 Mbps 750...

Page 10: ...0 EX180 C 1 EX180 C 2 Note S0700 is not yet UL compatible Thinner unit with low height Maximum 32 outputs How to Order SI Unit DN3 EX180 S Communication connector type Nil A T branch type Straight typ...

Page 11: ...5 RH With no condensation 500 VAC for 1 min between whole external terminal and FG 10 M or more 500 VDC between whole external terminal and FG CE marking UL CSA 110 g or less including accessory Sourc...

Page 12: ...r supply connector For solenoid valve Power supply connector Control unit power supply for SI unit Communication connector M3 Ground terminal Before mounting connector accessory Power supply connector...