background image

Arm length

Clamp arm

Fulcrum Extension arm

Shim
Clamping block

Load cell

Bore size: 

50

Bore size: 

63

0

2000

4000

6000

8000

10000

12000

50

100

150

200

250

300

0.8 MPa

0.5 MPa

0.3 MPa

Arm length [mm]

Maximum clamping force [N]

Arm length [mm]

Maximum clamping force [N]

10000

8000

6000

4000

2000

0

50

100

150

200

250

300

0.8 MPa

0.5 MPa

0.3 MPa

Relation between arm length and clamping force

CKZ3T-X2734

Model Selection

Calculation 

example

  Bore size: 63, Arm length: 200 mm,  

Operating pressure: 0.5 MPa
With  an  arm  length  of  200  mm  and  an  operating  
pressure  of  0.5  MPa,  according  to  the  graph,  the 
maximum clamping force becomes 2000 N.

7

Summary of Contents for CKZ3T-X2734 Series

Page 1: ...cture prevents intrusion of spatter Select from two types of top cover Rubber cover Rounded design reduces accumulation of welding spatter Equivalent to UL94 standard V0 Flame resistant Metal cover Su...

Page 2: ...rder Power Clamp Cylinder 50 63 CKZ3T X2734 Arm mounted Cylinder port 15 15 30 30 45 45 60 60 75 75 90 90 105 105 120 120 135 135 Nil G TN NPT TP Rc 50 50 equivalent 63 63 equivalent T TURCK P P F W N...

Page 3: ...nder Without Arm kg Bore size Arm opening angle 15 30 45 60 75 90 105 120 135 50 3 2 3 2 3 1 3 1 3 1 3 1 3 1 3 1 3 0 63 4 4 4 4 4 3 4 3 4 3 4 3 4 2 4 2 4 2 Manufacturer TURCK P F Supply voltage 10 to...

Page 4: ...t Bore size 050 50 equivalent 063 63 equivalent Bore size 050 50 equivalent 063 63 equivalent Proximity switch T TURCK P P F W None Arm opening angle J 15 H 30 G 45 F 60 E 75 D 90 C 105 B 120 A 135 Ru...

Page 5: ...ver open Power Clamp Cylinder CKZ3T X2734 mm Bore size B C D E GA GB I J K L LA LB MM N NA NB NC NN Rubbercover Metal cover 50 92 48 12 13 7 95 166 10 12 55 376 6 155 5 78 4 78 4 M10 x 1 5 19 13 36 5...

Page 6: ...H7 through 2 x D2 through Center Right side 144 65 22 28 0 1 15 0 2 Offset CKZ3T X2734 Dimensions Clamp Arm Offset 15 mm Bore size 50 Bore size 63 Weight kg CKZT50 A015CS 0 8 CKZT50 A015CB 0 8 CKZT50...

Page 7: ...1 Center Right side Left side 2 x D1H7 through 2 x D2 through 9 Power Clamp Cylinder CKZ3T X2734 Dimensions Clamp Arm Offset 45 mm Bore size 50 Bore size 63 Weight kg CKZT50 A045CS 0 9 CKZT50 A045CB...

Page 8: ...g force N Arm length mm Maximum clamping force N 10000 8000 6000 4000 2000 0 50 100 150 200 250 300 0 8 MPa 0 5 MPa 0 3 MPa Relation between arm length and clamping force CKZ3T X2734 Model Selection C...

Page 9: ...se the product within the allowable values in the graphs shown below The load indicates the total weight of the clamp arm extension arm and clamp ing block When the operating time is 1 second Calculat...

Page 10: ...c energy is applied there is a possibility of damage 4 When using a side guide Attach the side guide so that a lateral load such as galling etc is not applied to the clamp arm A Place the workpiece su...

Page 11: ...cribed in step B insert an additional shim The thickness of the shim changes by the distance to the hard stop and the operating pressure Refer to the graphs on page 11 and consider the distance to the...

Page 12: ...on Bore size 50 Bore size 63 CKZ3T X2734 Relation between shim thickness and clamping force Use this figure as a guide as there is a tolerance of about 10 in the clamp cylinder body When a shim exceed...

Page 13: ...unt the top cover to the clamp cylinder then tighten to the specified tightening torque below 2 It is possible to change from a rubber cover type to a metal cover type Refer to the replacement parts p...

Page 14: ...s of a completely sealed structure in order to protect it from welding spatter Do not disassemble except for the replaceable parts as the performance may deteriorate 3 Precautions for vertical clampin...

Page 15: ...Safety Instructions Be sure to read the Handling Precautions for SMC Products M E03 3 and Operation Manual before use...

Reviews: