Arm length
Clamp arm
Fulcrum Extension arm
Shim
Clamping block
Load cell
Bore size:
50
Bore size:
63
0
2000
4000
6000
8000
10000
12000
50
100
150
200
250
300
0.8 MPa
0.5 MPa
0.3 MPa
Arm length [mm]
Maximum clamping force [N]
Arm length [mm]
Maximum clamping force [N]
10000
8000
6000
4000
2000
0
50
100
150
200
250
300
0.8 MPa
0.5 MPa
0.3 MPa
Relation between arm length and clamping force
CKZ3T-X2734
Model Selection
Calculation
example
Bore size: 63, Arm length: 200 mm,
Operating pressure: 0.5 MPa
With an arm length of 200 mm and an operating
pressure of 0.5 MPa, according to the graph, the
maximum clamping force becomes 2000 N.
7