background image

 

 

AM-SMV26EN 

 

Page 1 of 2 

 

Instruction Manual   

 

Mist Separator

 

AM80D/90D

 

 
 
 
 
 
 
 
 
 
The intended use of this product is to filter the air in the main line.

 

 

 

1 Safety Instructions 

These  safety  instructions  are  intended  to  prevent  hazardous  situations 
and/or  equipment  damage.  These  instructions  indicate  the  level  of 
potential hazard with the labels of “Caution,” “Warning” or “Danger.” 
They are all important notes for safety and must be followed in addition 
to International  Standards (ISO/IEC)

 *1)

, and other safety regulations. 

*1)

 ISO 4414: Pneumatic fluid power - General rules relating to 

systems.  
ISO 4413: Hydraulic fluid power - General rules relating to systems. 
IEC 60204-1: Safety of machinery - Electrical equipment of 
machines. (Part 1: General requirements) 
ISO 10218-1: Manipulating industrial robots -Safety.etc. 

This  manual  contains  essential  information  for  the  protection  of  users 
and others from possible injury and/or equipment damage. 

  Read  this  manual  before  using  the  product,  to  ensure  correct 

handling, and read the manuals of related apparatus before use. 

  Keep this manual in a safe place for future reference. 

  To ensure safety  of  personnel  and  equipment the safety instructions 

in  this  manual  must  be  observed,  along  with  other  relevant  safety 
practices. 

 

 

Caution 

Caution indicates a hazard with a low level of risk 
which, if not avoided, could result in minor or 
moderate injury. 

 

 

Warning 

Warning indicates a hazard with a medium level 
of risk which, if not avoided, could result in death 
or serious injury. 

 

 

Danger 

Danger indicates a hazard with a high level of risk 
which, if not avoided, will result in death or 
serious injury. 

 

Warning 

 

The  compatibility  of  the  product  is  the  responsibility  of  the 
person who designs the equipment or decides its specifications. 

  Since  the  product  specified  here  is  used  under  various  operating 

conditions, its compatibility  with  specific  equipment must  be  decided 
by  the  person  who  designs  the  equipment  or  decides  its 
specifications  based  on  necessary  analysis  and  test  results.  The 
expected performance and safety assurance of the equipment will be 
the  responsibility  of  the  person  who  has  determined  its  compatibility 
with  the  product.  This  person  should  also  continuously  review  all 
specifications  of  the  product  referring  to  its  latest  catalogue 
information, with a view to giving due consideration to any possibility 
of equipment failure when configuring the equipment. 

 

Only  personnel  with  appropriate  training  should  operate 
machinery and equipment. 

The product specified here may become unsafe if handled incorrectly. 
The assembly, operation and maintenance of machines or equipment

 

including  our  products  must  be  performed

 

by  an  operator  who  is 

appropriately trained and experienced. 

1 Safety Instructions - continued 

 

Do 

not 

service 

or 

attempt 

to 

remove 

product 

and 

machinery/equipment until safety is confirmed. 

1)  The  inspection  and  maintenance  of  machinery/equipment  should 
only be performed after measures to prevent falling or runaway of the 
driven objects have been confirmed.

 

2)  When  the  product  is  to  be  removed,  confirm  that  the  safety 
measures as mentioned above are implemented and the power from 
any  appropriate  source  is  cut,  and  read  and  understand  the  specific 
product precautions of all relevant products carefully.  
3) Before machinery/equipment is restarted, take measures to 
prevent unexpected operation and malfunction. 

 

Contact SMC beforehand and take special consideration of 
safety measures if the product is to be used in any of the 
following conditions. 

1) Conditions and environments outside of the given specifications, or 
use outdoors or in a place exposed to direct sunlight. 
2)  Installation  on  equipment  in  conjunction  with  atomic  energy, 
railways,  air  navigation,  space,  shipping,  vehicles,  military,  medical 
treatment, combustions  and  recreation,  or  equipment  in contact  with 
food  and  beverages,  emergency  stop  circuits,  clutch  and  brake 
circuits  in  press  applications,  safety  equipment  or  other  applications 
unsuitable  for  the  standard  specification  described  in  the  product 
catalogue. 
3)  An  application  which  could  have  negative  effects  on  people, 
property, or animals requiring special safety analysis. 
4)  Use  in  an  interlock  circuit,  which  requires  the  provision  of  double 
interlock for possible failure by using a mechanical protective function, 
and periodical checks to confirm proper operation. 

 

Always  ensure  compliance  with  relevant  safety  laws  and 
standards. 

All electrical work must be carried out in a safe manner by a qualified 
person in compliance with applicable national regulations. 

Caution 

 

The product is provided for use in manufacturing industries.

 

The product herein described is basically provided for peaceful use in 
manufacturing industries. 

If considering using the product in other industries, consult SMC 
beforehand and exchange specifications or a contract if necessary. 
If anything is unclear, contact your nearest sales branch. 
 

2 Specifications 

Refer to the operation manual for additional information on

 

this product. 

 

 
Model 

AM80D 

AM90D 

Port size 

1 1/2 

1 1/2, 2 

Weight 

4.7kg 

5.0kg 

S

c

o

p

e

 

Fluid 

Compressed air 

Inlet air pressure range 

0.1 to 1.0MPa

 

(1.6MPa)

 Note1)

 

Operating  fluid  temperature 

-5 to 60

O

C (No freezing) 

Ambient temperature 

-5 to 60

O

C (No freezing) 

Proof pressure 

1.5MPa

 

(2.4MPa)

 Note 1)

 

R

a

te

d

 

c

o

n

d

it

ion
s

 

Air flow capacity  m

3

/min(ANR)

 Note 2)

 

11.0 

14.5 

Flow  capacity  of    the  compressor 
intake condition  m

3

/min

 Note 3)

 

11.5 

15.1 

Inlet air pressure 

0.7MPa 

Filtration 

 Note 4)

 

0.1μm (Filtration efficiency: 99%)

 

Oil mist density at outlet

Note5)

 

Max 1mg/m3 (ANR)(

0.8ppm) 

Note 1) When selecting Option H or Option J 
Note 2) Air flow capacity with 20 

o

C, atmospheric pressure and relative 

humidity of 65 %. 
Note 3) Air flow capacity with 32 

o

C, and when calculated to atmospheric 

pressure. 
Note 4) Filtration efficiency for conditions below in addition to the rated 
conditions above [Test condition ISO8573-4: 2010 compliant]. 

   * Flow capacity, inlet pressure and the amount of solid bodies at the filter 
inlet are stable. 
   * New element 
 

Specifications - continued 

Note 5) Water droplet elimination ratio for conditions below in addition to the rated 
conditions above. 
   * Oil mist density at outlet for conditions below in addition to the rated conditions 

above [Compliant to test condition ISO8573-9:2010 and test method 
ISO12500-4:2009] (Water droplet indicates condensed moisture. Water vapour 
which is not condensed is not included) 

   * Inlet air temperature = 25 

o

   * Flow capacity, inlet pressure and the water droplet concentration at the filter  

inlet are stable. 

   * New element 

3 Installation 

3.1  Installation 

Warning 

Do not install the product unless the safety instructions have been read 

and understood. 

Confirm the specifications. 

This product is designed for use in compressed air systems only. 
Do  not  operate  at  conditions  outside  of  the  specification,  as  this  could 
cause  damage,  malfunction  or  performance  reduction.  SMC  does  not 
guarantee  against  any  damage  if  the  product  is  used  outside  of  the 
specification range. 

Air source 

  Applicable fluid is compressed air. 

Do not use this product with a fluid other than compressed air  
(e.g. oxygen, hydrogen, inflammable gas, mixed gas, etc.). 

  Do  not  use  compressed  air  which  includes  chemicals,  organic 

solvents,  or  corrosive  gases,  etc

.  It  may  lead  to  damage  or 

malfunction. 

  Do  not  use  for  caisson  shield,  breathing,  medical  purposes,  air 

blow to any medicines and foods that enter the human body. 

Air preparation equipment including this product is for exclusive use for 
industrial compressed air. Do not use for any other purposes.

 

Model selection 

  Carefully  consider  the  application,  required  specifications,  and 

operating conditions (pressure, flow rate, temperature, environment and 
power  supply)  in  accordance  with  the  latest  catalogue  (SMC  website), 

making sure not to exceed the specification range. 

  Although it depends on the types or specifications of the compressor, 

compressed air generally contains particle contaminants. Please select 
the  system  construction  in  reference  to  the  model  selection  of  air 
preparation equipment in accordance with the user required cleanliness 
of the compressed air or applications.  
Contaminants contained in the compressed air: 
-  Moisture (water droplet, water vapour) 
-  Dust and chemicals which are sucked from the ambient air 
-  Deteriorated oils coming out of the compressor  
-  Solid foreign matter or oils including rust in the piping 

Select the model so that the maximum value (instantaneous) of the 
flow rate will not exceed the rated air capacity.

 

When  compressed  air  is  used  for  air  blow,  calculate  the  maximum 
amount of the consumed air before selecting the size. If compressed air 

Reviews: