AM-SMV26EN
Page 1 of 2
Instruction Manual
Mist Separator
AM80D/90D
The intended use of this product is to filter the air in the main line.
1 Safety Instructions
These safety instructions are intended to prevent hazardous situations
and/or equipment damage. These instructions indicate the level of
potential hazard with the labels of “Caution,” “Warning” or “Danger.”
They are all important notes for safety and must be followed in addition
to International Standards (ISO/IEC)
*1)
, and other safety regulations.
*1)
ISO 4414: Pneumatic fluid power - General rules relating to
systems.
ISO 4413: Hydraulic fluid power - General rules relating to systems.
IEC 60204-1: Safety of machinery - Electrical equipment of
machines. (Part 1: General requirements)
ISO 10218-1: Manipulating industrial robots -Safety.etc.
This manual contains essential information for the protection of users
and others from possible injury and/or equipment damage.
Read this manual before using the product, to ensure correct
handling, and read the manuals of related apparatus before use.
Keep this manual in a safe place for future reference.
To ensure safety of personnel and equipment the safety instructions
in this manual must be observed, along with other relevant safety
practices.
Caution
Caution indicates a hazard with a low level of risk
which, if not avoided, could result in minor or
moderate injury.
Warning
Warning indicates a hazard with a medium level
of risk which, if not avoided, could result in death
or serious injury.
Danger
Danger indicates a hazard with a high level of risk
which, if not avoided, will result in death or
serious injury.
Warning
The compatibility of the product is the responsibility of the
person who designs the equipment or decides its specifications.
Since the product specified here is used under various operating
conditions, its compatibility with specific equipment must be decided
by the person who designs the equipment or decides its
specifications based on necessary analysis and test results. The
expected performance and safety assurance of the equipment will be
the responsibility of the person who has determined its compatibility
with the product. This person should also continuously review all
specifications of the product referring to its latest catalogue
information, with a view to giving due consideration to any possibility
of equipment failure when configuring the equipment.
Only personnel with appropriate training should operate
machinery and equipment.
The product specified here may become unsafe if handled incorrectly.
The assembly, operation and maintenance of machines or equipment
including our products must be performed
by an operator who is
appropriately trained and experienced.
1 Safety Instructions - continued
Do
not
service
or
attempt
to
remove
product
and
machinery/equipment until safety is confirmed.
1) The inspection and maintenance of machinery/equipment should
only be performed after measures to prevent falling or runaway of the
driven objects have been confirmed.
2) When the product is to be removed, confirm that the safety
measures as mentioned above are implemented and the power from
any appropriate source is cut, and read and understand the specific
product precautions of all relevant products carefully.
3) Before machinery/equipment is restarted, take measures to
prevent unexpected operation and malfunction.
Contact SMC beforehand and take special consideration of
safety measures if the product is to be used in any of the
following conditions.
1) Conditions and environments outside of the given specifications, or
use outdoors or in a place exposed to direct sunlight.
2) Installation on equipment in conjunction with atomic energy,
railways, air navigation, space, shipping, vehicles, military, medical
treatment, combustions and recreation, or equipment in contact with
food and beverages, emergency stop circuits, clutch and brake
circuits in press applications, safety equipment or other applications
unsuitable for the standard specification described in the product
catalogue.
3) An application which could have negative effects on people,
property, or animals requiring special safety analysis.
4) Use in an interlock circuit, which requires the provision of double
interlock for possible failure by using a mechanical protective function,
and periodical checks to confirm proper operation.
Always ensure compliance with relevant safety laws and
standards.
All electrical work must be carried out in a safe manner by a qualified
person in compliance with applicable national regulations.
Caution
The product is provided for use in manufacturing industries.
The product herein described is basically provided for peaceful use in
manufacturing industries.
If considering using the product in other industries, consult SMC
beforehand and exchange specifications or a contract if necessary.
If anything is unclear, contact your nearest sales branch.
2 Specifications
Refer to the operation manual for additional information on
this product.
Model
AM80D
AM90D
Port size
1 1/2
1 1/2, 2
Weight
4.7kg
5.0kg
S
c
o
p
e
Fluid
Compressed air
Inlet air pressure range
0.1 to 1.0MPa
(1.6MPa)
Note1)
Operating fluid temperature
-5 to 60
O
C (No freezing)
Ambient temperature
-5 to 60
O
C (No freezing)
Proof pressure
1.5MPa
(2.4MPa)
Note 1)
R
a
te
d
c
o
n
d
it
ion
s
Air flow capacity m
3
/min(ANR)
Note 2)
11.0
14.5
Flow capacity of the compressor
intake condition m
3
/min
Note 3)
11.5
15.1
Inlet air pressure
0.7MPa
Filtration
Note 4)
0.1μm (Filtration efficiency: 99%)
Oil mist density at outlet
Note5)
Max 1mg/m3 (ANR)(
≒
0.8ppm)
Note 1) When selecting Option H or Option J
Note 2) Air flow capacity with 20
o
C, atmospheric pressure and relative
humidity of 65 %.
Note 3) Air flow capacity with 32
o
C, and when calculated to atmospheric
pressure.
Note 4) Filtration efficiency for conditions below in addition to the rated
conditions above [Test condition ISO8573-4: 2010 compliant].
* Flow capacity, inlet pressure and the amount of solid bodies at the filter
inlet are stable.
* New element
2 Specifications - continued
Note 5) Water droplet elimination ratio for conditions below in addition to the rated
conditions above.
* Oil mist density at outlet for conditions below in addition to the rated conditions
above [Compliant to test condition ISO8573-9:2010 and test method
ISO12500-4:2009] (Water droplet indicates condensed moisture. Water vapour
which is not condensed is not included)
* Inlet air temperature = 25
o
C
* Flow capacity, inlet pressure and the water droplet concentration at the filter
inlet are stable.
* New element
3 Installation
3.1 Installation
Warning
Do not install the product unless the safety instructions have been read
and understood.
Confirm the specifications.
This product is designed for use in compressed air systems only.
Do not operate at conditions outside of the specification, as this could
cause damage, malfunction or performance reduction. SMC does not
guarantee against any damage if the product is used outside of the
specification range.
Air source
Applicable fluid is compressed air.
Do not use this product with a fluid other than compressed air
(e.g. oxygen, hydrogen, inflammable gas, mixed gas, etc.).
Do not use compressed air which includes chemicals, organic
solvents, or corrosive gases, etc
. It may lead to damage or
malfunction.
Do not use for caisson shield, breathing, medical purposes, air
blow to any medicines and foods that enter the human body.
Air preparation equipment including this product is for exclusive use for
industrial compressed air. Do not use for any other purposes.
Model selection
Carefully consider the application, required specifications, and
operating conditions (pressure, flow rate, temperature, environment and
power supply) in accordance with the latest catalogue (SMC website),
making sure not to exceed the specification range.
Although it depends on the types or specifications of the compressor,
compressed air generally contains particle contaminants. Please select
the system construction in reference to the model selection of air
preparation equipment in accordance with the user required cleanliness
of the compressed air or applications.
Contaminants contained in the compressed air:
- Moisture (water droplet, water vapour)
- Dust and chemicals which are sucked from the ambient air
- Deteriorated oils coming out of the compressor
- Solid foreign matter or oils including rust in the piping
Select the model so that the maximum value (instantaneous) of the
flow rate will not exceed the rated air capacity.
When compressed air is used for air blow, calculate the maximum
amount of the consumed air before selecting the size. If compressed air