AM-SMV26EN
Page 2 of 2
4 Settings
Auto drain
Not pressurized
(After releasing
residual pressure)
Pressurized
(Pressure in the product: 0.1MPa or more)
Before drainage is
accumulated
When drainage is
accumulated
Drainage is released
(Open)
Drainage is not released
(Closed)
Drainage is released
(Open)
Manual release
The drain cock is usually tightened to the "S" side, but when it is rotated
to the "O" side, drainage can be released manually.
If the drainage is released while residual pressure is present in the filter,
drainage blows out from the drain port abruptly.
5 How to Order
Note 1) Even when the accessories are selected, they are not listed on the
product label.
Note 2) Bracket is included but not assembled. Mounting is to be performed by the
user.
Note 3) Option H and option J cannot be selected simultaneously.
6 Outline Dimensions (mm)
7 Maintenance
7.1 General Maintenance
Caution
Not following proper maintenance procedures could cause the
product to malfunction and lead to equipment damage.
If handled improperly, compressed air can be dangerous.
Maintenance of pneumatic systems should be performed only by
qualified personnel.
Before performing maintenance, turn off the power supply and be
sure to cut off the supply pressure. Confirm that the air is released to
atmosphere.
After installation and maintenance, apply operating pressure and
power to the equipment and perform appropriate functional and leakage
tests to make sure the equipment is installed correctly.
If any electrical connections are disturbed during maintenance, ensure
they are reconnected correctly and safety checks are carried out as
required to ensure continued compliance with applicable national
regulations.
Do not make any modification to the product.
7 Maintenance - continued
Do not disassemble the product, unless required by installation or
maintenance instructions.
Removal of equipment, and supply/exhaust of compressed air
When equipment is to be removed, first confirm that measures are in
place to prevent losing control of the equipment or workpieces from
falling, etc. Then, shut off the supply air and exhaust the compressed
air in the system.
When machinery is restarted, turn off the power supply, stop the air
supply and exhaust all compressed air from the system
Element replacement with a new one when the replacement
timing has come
If an element is used even after exceeding the replacement timing, the
outlet compressed air cleanliness might be reduced or oil mist may leak
out, which may damage the element.
Element replacement timing
Element should be replaced when the red piston of the service indicator
is visible or 2 years after starting operation, whichever comes first.
Element service indicator
Perform periodical check to find cracks, flaws or other deterioration. If
any are seen, replace with new parts and review the operating condition.
Otherwise, a malfunction may occur. Please consult SMC if the review
of the operating conditions is not possible.
Be sure to exhaust the drainage that has accumulated in the
filter
Operation with condensate caught in the equipment or the piping may
lead to operation failure of the equipment, splashing from the outlet, and
unexpected accidents.
Clean the bowl regularly
Clean inside of the bowl with tepid water in which detergent is dissolved
(25
O
C or less), and eliminate foreign matter and oil. If foreign matter or
drain scale is accumulated, it could cause operation failure of the auto
drain, so please clean it regularly. If necessary, remove the auto drain
from the bowl before cleaning. Please refer to Auto drain replacement
on page 14 of operation manual for removal of the auto drain.
Service parts
Description
Part No.
Element
AM-EL80D
AM-EL90D
8 Limitations of Use
8.1 Limited warranty and Disclaimer/Compliance Requirements
The product used is subject to the
following “Limited warranty
and Disclaimer” and “Compliance Requirements”. Read and
accept them before using the product
.
Limited warranty and Disclaimer
1) The warranty period of the product is 1 year in service or 1.5 years
after the product is delivered, whichever is first. Also, the product may
have specified durability, running distance or replacement parts. Please
consult your nearest sales branch.
2) For any failure or damage reported within the warranty period which
is clearly our responsibility, a replacement product or necessary parts
will be provided.
This limited warranty applies only to our product independently, and not
to any other damage incurred due to the failure of the product.
3) Prior to using SMC products, please read and understand the
warranty terms and disclaimers noted in the specified catalogue for the
particular products.
Compliance Requirements
1) The use of SMC products with production equipment for the
manufacture of weapons of mass destruction (WMD) or any other
weapon is strictly prohibited.
2) The exports of SMC products or technology from one country to
another are governed by the relevant security laws and regulations of
the countries involved in the transaction. Prior to the shipment of a
SMC product to another country, assure that all local rules governing
that export are known and followed.
If an error is generated, turn off the power supply and stop the
compressed air supply.
If smoke, abnormal smells or noises are generated, there is a possibility
of fire. In that case, stop supplying the compressed air and reduce the
pressure in the equipment to zero.
When maintenance of the auto drain is performed, or filter element
is replaced, be sure to reduce the compressed air to zero. Do not
touch the high temperature section.
Using this product at a high temperature (40 to 60
o
C) may cause burns.
Be sure to confirm that the temperature of the container or operating
part is reduced to 40 degrees or less to prevent burns.
0 Limitations of Use - continued
About oil-free products
The A