![SMC Networks AFF Series Manual Download Page 126](http://html1.mh-extra.com/html/smc-networks/aff-series/aff-series_manual_1301071126.webp)
AFM20
P
1
=0.3MP
a
P
1
=0.5MP
a
P
1
=0.7MP
a
P
1
=0.3MP
a
P
1
=0.5MP
a
P
1
=0.7MP
a
AFD20
P
1
=0.3MP
a
P
1
=0.5MP
a
P
1
=0.7MP
a
P
1
=0.3MP
a
P
1
=0.5M
Pa
P
1
=0.7MP
a
AFM30
P
1
=0.3MP
a
P
1
=0.5MP
a
P
1
=0.7MP
a
P
1
=0.3MP
a
P
1
=0.5MP
a
P
1
=0.7MP
a
AFD30
P
1
=0.3M
Pa
P
1
=0.5MP
a
P
1
=0.7MP
a
P
1
=0.3MP
a
P
1
=0.5MP
a
P
1
=0.7MP
a
AFM40
P
1
=0.3MP
a
P
1
=0.5MP
a
P
1
=0.7MP
a
P
1
=0.3MP
a
P
1
=0.5MP
a
P
1
=0.7MP
a
AFD40
P
1
=0.3MP
a
P
1
=0.5MP
a
P
1
=0.7MP
a
P
1
=0.3MP
a
P
1
=0.5MP
a
P
1
=0.7MP
a
Flow rate (
l
/min (ANR))
Pressure drop (MPa)
Flow rate (
l
/min (ANR))
Pressure drop (MPa)
Flow rate (
l
/min (ANR))
Pressure drop (MPa)
Flow rate (
l
/min (ANR))
Pressure drop (MPa)
Flow rate (
l
/min (ANR))
Pressure drop (MPa)
Flow rate (
l
/min (ANR))
Pressure drop (MPa)
200
800
1000
400
600
0.04
0.03
0.02
0.01
0
0
100
200
300
500
400
600
0.04
0.03
0.02
0.01
0
0
50
100
150
200
0.04
0.03
0.02
0.01
0
0
100
200
300
500
400
600
0.04
0.03
0.02
0.01
0
0
50
100
0.04
0.03
0.02
0.01
0
0
50
100
150
200
0.04
0.03
0.02
0.01
0
0
Flow Characteristics
(Representative values)
: When saturated with oil
: Initial state
Air Supply
1.
Install an air filter (AF series) as a pre-filter on the inlet side of
the mist separator to prevent premature clogging.
2.
Install a mist separator (AFM series) as a pre-filter on the inlet
side of the micro mist separator to prevent premature clogging.
3.
Do not install on the inlet side of the dryer as this can cause
premature clogging of the element.
Caution
Maintenance
1.
Replace the element every 2 years or when the pressure drop
becomes 0.1 MPa, whichever comes first, to prevent damage
to the element.
Warning
Design
1.
Design the system so that the mist separator is installed in a
pulsation-free location. The difference between internal and
external pressure inside the element should be kept within 0.1
MPa, as exceeding this value could cause damage.
Caution
Selection
1.
Do not allow air flow that exceeds the rated flow. If the air flow
is allowed outside the range of the rated flow even momentar-
ily, drainage and lubricant may splash at the outlet side or
cause damage to the component.
2.
Do not use in a low pressure application (such as a blower).
F.R.L. unit has its own minimum operating pressure depending
on the equipment and is designed specifically to function with
compressed air. If used below the minimum operating pressure,
a loss of performance and malfunction can occur. Please contact
SMC if an application under such conditions cannot be avoided.
Caution
Be sure to read before handling.
Refer to front matters 42 and 43 for Safety Instructions and pages 287 to 291 for F.R.L. Precautions.
Specific Product Precautions
340
Series
AFM20
to
AFM40
Series
AFD20
to
AFD40
P0295-P0364-E.qxd 08.11.6 2:06 PM Page 340
Summary of Contents for AFF Series
Page 38: ...178 P0141 P0220 E qxd 08 11 6 1 51 PM Page 178...
Page 91: ...305 AC AF AR AL AW A G AV AF800 AF900 P0295 P0364 E qxd 08 11 6 2 05 PM Page 305...
Page 95: ...309 AC AF AR AL AW A G AV AF800 AF900 P0295 P0364 E qxd 08 11 6 2 05 PM Page 309...
Page 99: ...313 AC AF AR AL AW A G AV AF800 AF900 P0295 P0364 E qxd 08 11 6 2 05 PM Page 313...
Page 103: ...317 AC AF AR AL AW A G AV AF800 AF900 P0295 P0364 E qxd 08 11 6 2 05 PM Page 317...
Page 123: ...337 AC AF AR AL AW A G AV AF800 AF900 P0295 P0364 E qxd 08 11 6 2 06 PM Page 337...
Page 142: ...356 P0295 P0364 E qxd 08 11 6 2 06 PM Page 356...
Page 150: ...364 P0295 P0364 E qxd 08 11 6 2 06 PM Page 364...
Page 171: ...385 AC AF AR AL AW A G AV AF800 AF900 P0365 P0446 E qxd 08 11 6 2 09 PM Page 385...