background image

Summary of Contents for 8505T - annexe 1

Page 1: ...SMC8505TX SMC8508TX ...

Page 2: ......

Page 3: ...38 Tesla Irvine CA 92618 Phone 949 679 8000 EZ Switch 10 100 1000 User Guide From SMC s EZ line of low cost workgroup LAN solutions July 2003 Pub 150000005200H R01 ...

Page 4: ...use No license is granted by implication or otherwise under any patent or patent rights of SMC SMC reserves the right to change specifications at any time without notice SMC Networks Inc 38 Tesla Irvine CA 92618 All rights reserved Printed in Taiwan Trademarks SMC is a registered trademark and EZ Switch is a trademark of SMC Networks Inc Other product and company names are trademarks or registered...

Page 5: ...ncorporates these newer technologies At that point the obsolete product is discontinued and is no longer an Active SMC product A list of discontinued products with their respective dates of discontinuance can be found at http www smc com index cfm action customer_service_warranty All products that are replaced become the property of SMC Replacement products may be either new or reconditioned Any r...

Page 6: ...CIDENT FIRE LIGHTNING OR OTHER HAZARD LIMITATION OF LIABILITY IN NO EVENT WHETHER BASED IN CONTRACT OR TORT INCLUDING NEGLIGENCE SHALL SMC BE LIABLE FOR INCIDENTAL CONSEQUENTIAL INDIRECT SPECIAL OR PUNITIVE DAMAGES OF ANY KIND OR FOR LOSS OF REVENUE LOSS OF BUSINESS OR OTHER FINANCIAL LOSS ARISING OUT OF OR IN CONNECTION WITH THE SALE INSTALLATION MAINTENANCE USE PERFORMANCE FAILURE OR INTERRUPTIO...

Page 7: ...d Consult the dealer or an experienced radio TV technician for help EC Conformance Declaration Class B SMC contact for these products in Europe is SMC Networks Europe Edificio Conata II Calle Fructuós Gelabert 6 8 2o 4a 08970 Sant Joan Despí Barcelona Spain This information technology equipment complies with the requirements of the Council Directive 89 336 EEC on the Approximation of the laws of t...

Page 8: ...B Safety Compliance CSA NRTL C22 2 950 UL 1950 EN60950 IEC 950 Electrical fast transient burst according to EN 61000 4 4 1995 AC DC power supply 1 kV Data Signal lines 0 5 kV Surge immunity test according to EN 61000 4 5 1995 AC DC Line to Line 1 kV AC DC Line to Earth 2 kV Immunity to conducted disturbances Induced by radio frequency fields EN 61000 4 6 1996 0 15 80 MHz with 1 kHz AM 80 Modulatio...

Page 9: ...itraum nicht benutzt sollten Sie es vom Stromnetz trennen Somit wird im Falle einer Überspannung eine Beschädigung vermieden 12 Durch die Lüftungsöffnungen dürfen niemals Gegenstände oder Flüssigkeiten in das Gerät gelangen Dies könnte einen Brand bzw elektrischen Schlag auslösen 13 Öffnen sie niemals das Gerät Das Gerät darf aus Gründen der elektrischen Sicherheit nur von authorisiertem Servicepe...

Page 10: ...COMPLIANCES vi ...

Page 11: ... to an RJ 45 Port 5 Powering On the Switch 7 Verifying Port Status 8 Verifying System Operation 8 Applications 9 Product Specifications 11 Physical Characteristics 11 EMC Safety Compliances 12 Troubleshooting 13 Diagnosing Switch Indicators 13 Power and Cooling Problems 14 Installation 14 Cables 15 Cable Specifications 15 10BASE T 100BASE TX Pin Assignments 15 1000BASE T Pin Assignments 16 1000BAS...

Page 12: ...viii ...

Page 13: ...ands on your network s limited resources Description of Hardware The EZ Switch 10 100 1000 SMC8505T SMC8508T is an 5 8 port Gigabit Ethernet switch The 10BASE T 100BASE TX 1000BASE T ports deliver dedicated 10 100 1000 Mbps links to each attached LAN segment All RJ 45 ports on this switch operate at 10 100 or 1000 Mbps 10 100 Mbps connections support auto negotiation of speed flow control and dupl...

Page 14: ...ntegrity is always maintained even under heavy loading Easy installation and reliability make this plug and play switch an ideal choice for delivering high speed Internet access to multiple users The following figures show the components of this switch Front and Rear Panels SMC8505T SMC8508T EZSwitch 10 100 1000 8505T EZSwitch 10 100 1000 8505T 1A EZSwitch 10 100 1000 8508T EZSwitch 10 100 1000 85...

Page 15: ... requirements sufficient physical space and proximity to other network devices that are to be connected Verify the following installation requirements Power requirements 100 to 240 VAC 10 at 50 to 60 Hz 3Hz The switch s power supply automatically adjusts to the input voltage level The switch should be located in a cool dry place with at least 10 cm 4 in of space on the sides for ventilation Place ...

Page 16: ...ck 3 Repeat step 1 for each switch before stacking them The rubber foot pads cushion the switch against shock vibrations and provide space between each switch for ventilation Mounting Switches in a Rack Please comply with the following instructions to ensure that your switch is securely mounted in the rack 1 Use a standard EIA 19 inch rack 2 Use the brackets and screws supplied in the rack mountin...

Page 17: ... attached device Making a Connection to an RJ 45 Port Because all RJ 45 ports on these switches support automatic MDI MDI X operation you can use straight through cables for all network connections to PCs or servers or to other switches or hubs Note that auto negotiation must be enabled for automatic MDI MDI X pinout configuration 1 Prepare the network devices you wish to network Make sure you hav...

Page 18: ...ll network connections or testing existing Category 5 cable to be sure that it complies with the IEEE 802 3ab standards See 1000BASE T Cable Requirements on page 17 Restrictions on Cascade Length The IEEE 802 3 standard recommends restricting the number of hubs i e repeaters cascaded via twisted pair cable to four while IEEE 802 3u provides even stricter recommendations for Fast Ethernet Therefore...

Page 19: ...he connected input voltage Therefore no additional adjustments are necessary when connecting it to any input voltage within the range marked on the rear panel 3 The switch performs a self diagnostic test upon power on Note that this test takes several seconds to complete Note The unit supports a hot remove feature which permits you to connect or disconnect twisted pair cables without powering off ...

Page 20: ...ing a link signal the port Port and System Status LEDs LED Condition Status Power On The switch is receiving power Ports Link Act On The port has established a valid network connection Off The port has not established any network connection Flashing Traffic is passing through the port 1000M On Indicates that the port is transmitting or receiving data at 1000 Mbps Off No link up at 1000M 10 100M On...

Page 21: ...x repeater or a server s network adapter All switch ports operate at 1 Gbps full duplex providing 2 Gbps of bandwidth to the attached device Bridging Functions This switch provides fully transparent bridging functions It automatically learns node addresses that are subsequently used to filter and forward all traffic based on the destination address When traffic passes between devices attached to t...

Page 22: ...peed servers EZ Switch 10 100 1000 SMC8508T Server SMC EZ109DT Workstations LAN 1 PWR WLAN WAN 2 3 Link Activity Notebook EZS wit ch 10 1 00 1 000 850 8T EZS wit ch 10 1 00 1 000 850 8T Internet Notebook with SMC2835W Wireless PC Card SMC2804WBR Wireless Broadband Router Workstations With SMC9452TX Gigabit PCI Cards ...

Page 23: ...duplex at 10 100 Mbps full duplex at 1000 Mbps Media Supported 10BASE T 100 ohm Category 3 4 5 twisted pair 100BASE TX 100 ohm Category 5 twisted pair 1000BASE T 100 ohm Category 5 or 5e twisted pair Number of Ports SMC8505T 5 RJ 45 1000BASE T ports SMC8508T 8 RJ 45 1000BASE T ports Indicator Panel Power Ports Link Act 1000M 10 100M Dimensions 19 64 x 11 65 x 3 66 cm 7 76 x 4 6 x 1 44 in ...

Page 24: ...on SMC8505T 12 Watts SMC8508T 15 Watts Power Requirement DC input SMC8505T 12 V 1 A SMC8508T 12 V 1 25 A Temperature Operating 0 40 ºC 32 98 ºF Storage 40 70 ºC 40 158 ºF Humidity 10 to 90 non condensing EMC Safety Compliances CE Mark Immunity EN 61000 4 2 3 4 5 6 8 11 Emissions FCC Class B CISPR Class B EN 61000 3 2 3 Safety CSA UL1950 CSA 22 2 950 TUV GS EN60950 ...

Page 25: ...D does not light after connection is made Probable Causes Switch port network card or cable may be defective Possible Solutions Check that the switch and attached device are both powered on Be sure the network cable is connected to both devices Verify that Category 5 cable is used for 100 Mbps connections Category 5 or 5e cable for 1000 Mbps connections and that the length of any cable does not ex...

Page 26: ...nections power losses or surges at the power outlet and verify that the fans on the right side of the unit are unobstructed and running prior to shutdown If you still cannot isolate the problem then the internal power supply may be defective Installation Verify that all system components have been properly installed If one or more components appear to be malfunctioning e g the power cord or networ...

Page 27: ...sure that the length of any twisted pair connection does not exceed 100 meters 328 feet Because all ports on this switch support automatic MDI MDI X operation you can use straight through cables for all network connections to PCs or servers or to other switches or hubs In straight through cable pins 1 2 3 and 6 at one end of the cable are connected straight through to pins 1 2 3 and 6 at the other...

Page 28: ...xceed 100 meters 328 feet Pin MDI X Signal Name MDI Signal Name 1 Receive Data plus RD Transmit Data plus TD 2 Receive Data minus RD Transmit Data minus TD 3 Transmit Data plus TD Receive Data plus RD 6 Transmit Data minus TD Receive Data minus RD 4 5 7 8 Not used at 10 100 Mbps Not used at 10 100 Mbps Pin MDI Signal Name MDI X Signal Name 1 Transmit Data plus TD1 Transmit Data plus TD2 2 Receive ...

Page 29: ... must pass tests for Attenuation Near End Crosstalk NEXT and Far End Crosstalk FEXT This cable testing information is specified in the ANSI TIA EIA TSB 67 standard Additionally cables must also pass test parameters for Return Loss and Equal Level Far End Crosstalk ELFEXT These tests are specified in the ANSI TIA EIA TSB 95 Bulletin The Additional Transmission Performance Guidelines for 100 Ohm 4 P...

Page 30: ...CABLES 18 ...

Page 31: ......

Page 32: ...3 455 72 88 Fax 31 33 455 73 30 Central Europe 49 0 89 92861 0 Fax 49 0 89 92861 230 Nordic 46 0 868 70700 Fax 46 0 887 62 62 Eastern Europe 34 93 477 4920 Fax 34 93 477 3774 Sub Saharian Africa 27 0126610232 Fax 27 11 314 9133 North West Africa 216 71236616 Fax 216 71751415 CIS 7 095 789 35 73 Fax 7 095 789 35 73 PRC Beijing 86 10 8251 1550 Fax 86 10 8251 1551 PRC Shanghai 86 21 6485 9922 Fax 86 ...

Reviews: