background image

TigerAccess

™ 

10/100

Fast Ethernet Switch

24 100BASE-BX Single-Fiber Ports

2 10/100/1000BASE-T ports shared with SFP slots

2 module slots for Gigabit extender modules

Non-blocking switching architecture

Spanning Tree Protocol, RSTP and MSTP

Up to 12 LACP or static 8-port trunks

Layer 2/3/4 CoS support through eight priority queues

Layer 3/4 traffic priority with IP Precedence and IP DSCP

Full support for VLANs with GVRP and QinQ

IGMP multicast filtering and snooping

Support for jumbo frames up to 9 KB

Manageable via console, Web, SNMP/RMON

Security features: ACL, RADIUS, 802.1X

Installation Guide

SMC7824M/FSW

Summary of Contents for 7824M/FSW

Page 1: ...anning Tree Protocol RSTP and MSTP Up to 12 LACP or static 8 port trunks Layer 2 3 4 CoS support through eight priority queues Layer 3 4 traffic priority with IP Precedence and IP DSCP Full support for VLANs with GVRP and QinQ IGMP multicast filtering and snooping Support for jumbo frames up to 9 KB Manageable via console Web SNMP RMON Security features ACL RADIUS 802 1X Installation Guide SMC7824...

Page 2: ......

Page 3: ...38 Tesla Irvine CA 92618 Phone 949 679 8000 TigerAccess 10 100 Installation Guide From SMC s Tiger line of feature rich workgroup LAN solutions January 2007 Pub 149100032500A ...

Page 4: ... implication or otherwise under any patent or patent rights of SMC SMC reserves the right to change specifications at any time without notice Copyright 2007 by SMC Networks Inc 38 Tesla Irvine CA 92618 All rights reserved Printed in Taiwan Trademarks SMC is a registered trademark and EZ Switch TigerAccess TigerStack and TigerSwitch are trademarks of SMC Networks Inc Other product and company names...

Page 5: ...ncorporates these newer technologies At that point the obsolete product is discontinued and is no longer an Active SMC product A list of discontinued products with their respective dates of discontinuance can be found at http www smc com index cfm action customer_service_warranty All products that are replaced become the property of SMC Replacement products may be either new or reconditioned Any r...

Page 6: ...IRE LIGHTNING OR OTHER HAZARD LIMITATION OF LIABILITY IN NO EVENT WHETHER BASED IN CONTRACT OR TORT INCLUDING NEGLIGENCE SHALL SMC BE LIABLE FOR INCIDENTAL CONSEQUENTIAL INDIRECT SPECIAL OR PUNITIVE DAMAGES OF ANY KIND OR FOR LOSS OF REVENUE LOSS OF BUSINESS OR OTHER FINANCIAL LOSS ARISING OUT OF OR IN CONNECTION WITH THE SALE INSTALLATION MAINTENANCE USE PERFORMANCE FAILURE OR INTERRUPTION OF ITS...

Page 7: ...ly approved by the party responsible for compliance could void your authority to operate the equipment You may use unshielded twisted pair UTP for RJ 45 connections Category 3 or better for 10 Mbps connections Category 5 or better for 100 Mbps connections Category 5 5e or 6 for 1000 Mbps connections For fiber optic connections you may use 50 125 or 62 5 125 micron multimode fiber or 9 125 micron s...

Page 8: ...s A for harmonic current emission according to EN 61000 3 2 1995 Limitation of voltage fluctuation and flicker in low voltage supply system according to EN 61000 3 3 1995 Immunity Product family standard according to EN 55024 1998 Electrostatic Discharge according to EN 61000 4 2 1995 Contact Discharge 4 kV Air Discharge 8 kV Radio frequency electromagnetic field according to EN 61000 4 3 1996 80 ...

Page 9: ...ook at the transmit laser while it is powered on Also never look directly at the fiber TX port and fiber cable ends when they are powered on Ne regardez jamais le laser tant qu il est sous tension Ne regardez jamais directement le port TX Transmission à fibres optiques et les embouts de câbles à fibres optiques tant qu ils sont sous tension Niemals ein Übertragungslaser betrachten während dieses e...

Page 10: ...sted circuit breaker or other appropriate disconnect device must be provided as part of the building installation France and Peru only This unit cannot be powered from IT supplies If your supplies are of IT type this unit must be powered by 230 V 2P T via an isolation transformer ratio 1 1 with the secondary connection point labelled Neutral connected directly to earth ground Impédance à la terre ...

Page 11: ...e si l équipement auquel il est raccordé fonctionne dans les mêmes conditions France et Pérou uniquement Ce groupe ne peut pas être alimenté par un dispositif à impédance à la terre Si vos alimentations sont du type impédance à la terre ce groupe doit être alimenté par une tension de 230 V 2 P T par le biais d un transformateur d isolement à rapport 1 1 avec un point secondaire de connexion portan...

Page 12: ...kleinstspannung gemäß IEC 60950 Diese Bedingungen sind nur gegeben wenn auch die an das Gerät angeschlossenen Geräte unter SELV Bedingungen betrieben werden PSE Alarm 本製品に同梱いたしております電源コードセットは 本製品専用です 本電源コードセットは 本製品以外の 製品並びに他の用途でご使用いただくことは出来ません 製品本体に同梱された電源コードセットを利用し 他製品 の電源コードセットを使用しないで下さい Danemark La prise mâle d alimentation doit respecter la section 107 2 D1 de la norme DK2 1a ou DK2 5a Suisse L...

Page 13: ...scharge when handling this equipment Caution Do not plug a phone jack connector in the RJ 45 port This may damage this device Les raccordeurs ne sont pas utilisé pour le système téléphonique Caution Use only twisted pair cables with RJ 45 connectors that conform to FCC standards Achtung Dieses Produkt enthält keine Teile die eine Wartung vom Benutzer benötigen Achtung Installation und Deinstallati...

Page 14: ...re no hazardous nor ozone depleting materials in this product Documentation All printed documentation for this product uses biodegradable paper that originates from sustained and managed forests The inks used in the printing process are non toxic Purpose This guide details the hardware features of the switches including their physical and performance related characteristics and how to install each...

Page 15: ...1 5 Port and System Status LEDs 1 6 Fan Tray 1 8 Power Modules 1 9 Optional Media Extender Module 1 10 1000BASE Combo Module 1 10 Features and Benefits 1 11 Connectivity 1 11 Expandability 1 11 Performance 1 11 Management 1 12 2 Network Planning 2 1 Fiber To The Home FTTH 2 1 Connection Examples 2 2 Downlink Fiber Connections 2 3 Uplink Connections 2 4 Management Connections 2 5 Private VLAN Conne...

Page 16: ...Connecting to the Console Port 3 14 Wiring Map for Serial Cable 3 14 Connecting to the Alarm Port 3 15 Wiring Map for Alarm Cable 3 16 4 Making Network Connections 4 1 Connecting Network Devices 4 1 Twisted Pair Devices 4 1 Cabling Guidelines 4 1 Connecting to PCs Servers Hubs and Switches 4 2 Network Wiring Connections 4 3 Fiber Optic Devices 4 4 Connectivity Rules 4 6 1000BASE T Cable Requiremen...

Page 17: ...r Existing Category 5 Cable B 6 Adjusting Existing Category 5 Cabling to Run 1000BASE T B 6 Fiber Standards B 7 C Specifications C 1 Physical Characteristics C 1 Switch Features C 3 Management Features C 3 Standards C 4 Compliances C 4 Extender Modules C 5 Gigabit Extender Module RJ 45 SFP C 5 D German Instructions D 1 Eine Site Auswählen Selecting a Site D 1 Montage Rack Mounting Instructions D 2...

Page 18: ...TABLE OF CONTENTS xviii E Ordering Information E 1 Glossary Index ...

Page 19: ... Table 4 3 Maximum 1000BASE LX Gigabit Ethernet Cable Length 4 7 Table 4 4 Maximum 1000BASE ZX Gigabit Ethernet Cable Length 4 7 Table 4 5 Maximum Fast Ethernet Cable Length 4 8 Table 4 6 Maximum 100BASE BX Fast Ethernet Cable Length 4 8 Table 4 7 Maximum Ethernet Cable Length 4 8 Table A 1 Diagnosing Switch Indicators A 1 Table B 1 10 100BASE TX MDI and MDI X Port Pinouts B 2 Table B 2 1000BASE T...

Page 20: ...Attaching the Adhesive Feet 3 6 Figure 3 5 Installing an Optional Module 3 7 Figure 3 6 Inserting an SFP Transceiver into a Slot 3 8 Figure 3 7 DC Plug Connections 3 12 Figure 3 8 AC Power Receptacle 3 13 Figure 3 9 Serial Port RJ 45 Pin Out 3 14 Figure 3 10 Alarm Port D 15 Pin Out 3 15 Figure 3 11 External Alarm I O Connections 3 17 Figure 4 1 Making Twisted Pair Connections 4 2 Figure 4 2 Networ...

Page 21: ...ransceivers giving you the option of placing the switch either in the CO or anywhere along the path between the CO and the subscriber The switch also includes two slots for optional Gigabit Ethernet combination modules with one 10 100 1000BASE TX SFP port which can provide additional uplink capacity The switch has one 10 100BASE TX port for dedicated management access which can be operated outside...

Page 22: ...y on all ports The switch also features full duplex capability on all ports which effectively doubles the bandwidth of each connection For communications within the same VLAN the switch uses store and forward switching to ensure maximum data integrity With store and forward switching the entire packet must be received into a buffer and checked for validity before being forwarded This prevents erro...

Page 23: ...witch over either a local or remote connection to the management port when access via the data channel is not possible or deemed insecure For a detailed description of the switch s advanced features refer to the SMC7824M FSW Management Guide Description of Hardware 100BASE BX SC Fiber Ports The switch provides 24 100BASE BX single fiber ports with SC connectors Each fiber port supports a full dupl...

Page 24: ...s auto negotiation of flow control so the switch can automatically prevent port buffers from becoming saturated 100BASE TX Management Port The 10 100BASE TX port labeled Mgmt provides a dedicated management interface which is segregated from the data traffic crossing the other ports This port supports auto negotiation so the optimum transmission mode half or full duplex and data rate 10 or 100 Mbp...

Page 25: ...000BASE SX transceivers use multimode duplex fiber cable while 1000BASE LX and 1000BASE ZX transceivers use single mode duplex fiber cable Alarm Interface Port The DB 15 alarm port on the switch s front panel can be used to provide alarm service port and BITS clock reference interfaces The switch supports two sets of alarm relay contacts major and minor and 4 external customer site alarm inputs It...

Page 26: ...play panel for key system and port indications that simplifies installation and network troubleshooting The LEDs which are located on the front panel and the power module trays for easy viewing are shown below and described in the following tables Figure 1 2 Port and System LEDs Mgmt Mgmt ...

Page 27: ...s failure of one or more fans Diag Flashing Green System self diagnostic test in progress Green System self diagnostic test successfully completed Off System self diagnostic test has detected a fault Link Activity Green Port has a valid link Flashing Green Flashing indicates activity on the port Off The link is down Power Module 48V 12V or AC 12V Green DC or AC power is functioning normally Off Ex...

Page 28: ...SS SWITCH 1 8 Fan Tray A removable fan tray on the right side of the front panel contains three fans that provide cooling for the chassis The following figure shows the fan tray removed from the switch Figure 1 3 Fan Tray ...

Page 29: ...r Modules This switch provides two power module options 48 VDC and universal AC For specifications on the power conversion modules and external input power requirements see Power Supply on page C 2 Figure 1 4 Optional Power Modules 4A ...

Page 30: ...000BASE T RJ 45 port Category 5 5e or 6 twisted pair cable can be used to connect to another device up to 100 m 328 ft away The 1000BASE T port operates at 10 100 and 1000 Mbps At 1000 Mbps it operates at full duplex and supports auto negotiation of flow control At 10 100 Mbps it supports auto negotiation of speed duplex mode i e half or full duplex and flow control Note that you should first test...

Page 31: ...he port can be configured manually RJ 45 10 100 1000BASE T ports support auto MDI MDI X pinout selection Unshielded UTP cable supported on all RJ 45 ports Category 3 or better for 10 Mbps connections Category 5 or better for 100 Mbps connections and Category 5 5e 6 or better for 1000 Mbps connections IEEE 802 3 2005 Ethernet Fast Ethernet Gigabit Ethernet compliance ensures compatibility with stan...

Page 32: ...raffic Supports wire speed switching Supports flow control using back pressure for half duplex and IEEE 802 3x for full duplex Management At a glance LEDs for easy troubleshooting Network management agent Manages switch in band or out of band Supports console Telnet SSH SNMP v1 v2c v3 RMON 4 groups and web based interface Dedicated management port for in band access ...

Page 33: ...ily extend an Ethernet connection over optical fiber directly to a subscriber This switch contains 24 100BASE BX full duplex single fiber single mode cable connections that run from the service provider s central office CO directly to the subscriber s CPE Each single mode fiber connection can be run up to a distance of 10 km from the CO The switch also provides two 1000BASE T SFP uplink ports for ...

Page 34: ...cal applications are described below This switch is designed to offer a cost effective solution for FTTH providing downlink connections to subscribers over fiber cable and high bandwidth uplink connections to core switches and routers at the CO using 1000BASE T twisted pair cable for short runs or fiber cable for longer runs A dedicated management port provides secure management access to the swit...

Page 35: ... A CPE is installed inside a subscriber s premises so there are no active outside components between the CO and the end user The figure below illustrates a basic switch to CPE connection Figure 2 1 Downlink Fiber Connections CPE 100BASE BX full duplex single fiber WDM l 0 ink to CO up to 1 km Subscriber s Home Central Office CO 10 100BASE TX UTP connection to computer up to 100 m FTTH Switch 8 7A ...

Page 36: ...h connection to a core switch or router at the CO Besides balancing the load across each port in the trunk the additional port provides redundancy by taking over the load if the other trunk port fails The figure below illustrates a trunk connection to other switches Figure 2 2 Uplink Fiber Connections Layer 2 3 Switch Link to Internet POP 1000BASE BX fiber trunk connection to Layer 2 3 switch up t...

Page 37: ...port network making it possible to re configure or troubleshoot the switch over either a local or remote connection to the management port when access via the data channel is not possible or deemed insecure The figure below illustrates management port connections to FTTH switches Figure 2 3 Management Port Connections 8 7A 8 7A Mgmt Mgmt Mgmt Mgmt 8 7A 8 7A Mgmt Mgmt Mgmt Mgmt 8 7A 8 7A Mgmt Mgmt ...

Page 38: ...security for each subscriber Furthermore the switch can control the bandwidth of downlink connections using traffic rate limiting Each fiber port downlink can be limited to values from 1 Mbps to 100 Mbps depending on the needs of the individual user The service provider can then charge subscribers according to the bandwidth provided The figure below illustrates Private VLAN connections to the swit...

Page 39: ... Layer 3 router For network applications that require routing between dissimilar network types attach the switch to a multi protocol router 3 As a general rule the length of fiber optic cable for a single switched link should not exceed 1000BASE SX 550 m 1805 ft for multimode fiber duplex fiber 1000BASE LX 10 km 6 2 miles for single mode fiber duplex fiber 1000BASE ZX 70 km 43 miles for single mod...

Page 40: ...NETWORK PLANNING 2 8 ...

Page 41: ...r outlet be able to maintain its temperature within 0 to 50 C 32 to 122 F and its humidity within 5 to 95 non condensing provide adequate space approximately five centimeters or two inches on all sides for proper air flow be accessible for installing cabling and maintaining the devices allow the status LEDs to be clearly visible Make sure twisted pair cable is always routed away from power lines f...

Page 42: ... T operation Check the following criteria against the current installation of your network Cable type Unshielded twisted pair UTP or shielded twisted pair STP cables with RJ 45 connectors Category 3 or better for 10BASE T Category 5 or better for 100BASE TX and Category 5 5e or 6 for 1000BASE T Protection from radio frequency interference emissions Electrical surge suppression Separation of electr...

Page 43: ...two brackets and eight screws for attaching the brackets to the switch Power cord either US Continental Europe or UK Console cable RJ 45 to RS 232 This Installation Guide Installation and Management Guide CD SMC Warranty Registration Card be sure to complete and return to SMC Optional Rack Mounting Equipment If you plan to rack mount the switches be sure to have the following equipment available F...

Page 44: ...y may be higher than the ambient room temperature check that the rack environment temperature is within the specified operating temperature range See page C 2 Mechanical Loading Do not place any equipment on top of a rack mounted unit Circuit Overloading Be sure that the supply circuit to the rack assembly is not overloaded Grounding Rack mounted equipment should be properly grounded To rack mount...

Page 45: ...ng the Switch in a Rack 3 If installing a single switch only turn to Grounding the Chassis at the end of this chapter 4 If installing multiple switches mount them in the rack one below the other in any order Desktop or Shelf Mounting 1 Attach the four adhesive feet to the bottom of the first switch Mgmt Mgmt ...

Page 46: ... sure there are at least two inches of space on all sides for proper air flow 3 If installing a single switch only go to Grounding the Chassis at the end of this chapter 4 If installing multiple switches attach four adhesive feet to each one Place each device squarely on top of the one below in any order 8 7A 8 7A Mg mtMg mt Mg mtMg mt ...

Page 47: ...te or a previously installed module from the appropriate slot by removing the two screws with a flat head screwdriver 2 Before opening the package that contains the module touch the bag to the switch casing to discharge any potential static electricity Also it is recommended to use an ESD wrist strap during installation 3 Remove the module from the anti static shielded bag 4 Holding the module lev...

Page 48: ...a valid link Installing an Optional SFP Transceiver Figure 3 6 Inserting an SFP Transceiver into a Slot This switch supports 1000BASE SX LX ZX SFP compatible transceivers To install an SFP transceiver do the following 1 Consider network and cabling requirements to select an appropriate SFP transceiver type 2 Insert the transceiver with the optical connector facing outward and the slot connector fa...

Page 49: ...compliance with ETSI ETS 300 253 2 Ensure that there is a good electrical connection to the grounding point on the rack no paint or isolating surface treatment 3 Disconnect all power cables to the switch 4 The switch chassis is connected internaly to 0 V This circuit is connected to the single hole grounding terminal on the back of the switch The surface area around this terminal is not painted in...

Page 50: ...ng and circuitry should be rated to carry a load at least two times the maximum rating for this switch see Power Supply on page C 2 2 The wiring between the DC power supply and the switch must be stranded copper wire within the range of 10 to 24 AWG 3 Wiring for the power input terminals on the switch are described below Wiring of the DC power supply terminals depends on the equipment in use on th...

Page 51: ...conductivity 5 Connect the external power feed and power ground return lines to the DC plug provided with the switch as shown below The power leads are labeled on the front of the chassis above the DC power connection block The 48 VDC power feed uses the 48VDC input and RETA B Return lines for power source A and B respectively Use a small flat tip screwdriver to loosen the screws on the power plug...

Page 52: ...on the front of the power conversion module to the ON position marked 11 Check the indicators on the power conversion module as the switch is powered on to verify that the 48V LED indicating external power status is on and that the 12V LED indicating internal power conversion is on If not recheck the power supply and power cable connections at the supply source and at power conversion module 12 If...

Page 53: ...ional use you may need to change the AC line cord You must use a line cord set that has been approved for the receptacle type in your country 3 Insert the plug on the other end of the power cable directly into the receptacle on the AC power module Figure 3 8 AC Power Receptacle 4 Check the indicators on the power module as the switch is powered on to verify that the AC LED indicating external powe...

Page 54: ...e configuration The on board configuration program can be accessed from a terminal or a PC running a terminal emulation program The pin assignments used to connect to the serial port are provided in the following table Figure 3 9 Serial Port RJ 45 Pin Out Wiring Map for Serial Cable Table 3 1 Serial Cable Wiring Switch s 8 Pin Serial Port Null Modem PC s 9 Pin DTE Port 6 RXD receive data 3 TXD tra...

Page 55: ...larm Port The DB 15 alarm port on the switch s front panel is used to provide alarm service port and BITS clock reference interfaces The switch supports two sets of alarm relay contacts major and minor and 4 external customer site alarm inputs It also provides an alarm cutoff button labeled ACO The pin assignments used to connect to the alarm port are provided in the following table Figure 3 10 Al...

Page 56: ... during major alarm state 7 MNR_ALARM_NO Normally open during minor alarm state 8 ALARM_IN4_EXT_RTN RTN indicates return to Ground External alarm input 4 external relay dry contact closure from pin 3 9 ALARM_IN1_EXT_P External alarm input 1 external relay dry contact closure to pin14 10 ALARM_IN2_EXT_P External alarm input 2 external relay dry contact closure to pin 15 11 MJR_ALARM_NC Normally clo...

Page 57: ... 3 4 NC NO COM Major Alarm NC NO COM Minor Alarm External Alarm Input 1 External Alarm Input 2 External Alarm Input 3 To backplane via internal signal converter circuits External input uses dry relay contact to pins 14 15 13 and 8 for grounding For active alarm the relay is closed Alarm Connector External Alarm Input 4 ALARM_IN1_EXT_P ALARM_IN1_EXT_RTN Alarm input is isolated by photo coupler ...

Page 58: ...INSTALLING THE SWITCH 3 18 ...

Page 59: ...r Devices Each device requires an unshielded twisted pair UTP cable with RJ 45 connectors at both ends Use Category 5 5e or 6 cable for 1000BASE T connections Category 5 or better for 100BASE TX connections and Category 3 or better for 10BASE T connections Cabling Guidelines The RJ 45 ports on the switch support automatic MDI MDI X pinout configuration so you can use standard straight through twis...

Page 60: ... 1 Making Twisted Pair Connections 2 If the device is a PC card and the switch is in the wiring closet attach the other end of the cable segment to a modular wall outlet that is connected to the wiring closet See Network Wiring Connections on page 4 3 Otherwise attach the other end to an available port on the switch Make sure each twisted pair cable does not exceed 100 meters 328 ft in length 3 As...

Page 61: ...able to an available port on the switch and the other end to the patch panel 2 If not already in place attach one end of a cable segment to the back of the patch panel where the punch down block is located and the other end to a modular wall outlet 3 Label the cables to simplify future troubleshooting See Cable Labeling and Connection Records on page 4 9 Figure 4 2 Network Wiring Connections 8 7A ...

Page 62: ...g at the same wavelength for both the transmit and receive signals SX 850 nm LX 1310 nm ZX 1550 nm Warning These switches use lasers to transmit signals over fiber optic cable The lasers are compliant with the requirements of a Class 1 Laser Product and are inherently eye safe in normal operation However you should never look directly at a transmit port when it is powered on Note When selecting a ...

Page 63: ...erformance on the port 3 When running cable to a subscriber connect one end of the cable to an 100BASE BX SC port on the switch and the other end to the CPE at the subscriber s premises Most CPEs require the fiber cable to be hard wired to the device with an internal splice which should only be done by trained service personnel When connecting to an uplink port connect one end of the cable to the ...

Page 64: ... your network please follow the connectivity rules listed in the manuals for these products However note that because switches break up the path for connected devices into separate collision domains you should not include the switch or connected cabling in your calculations for cascade length involving other devices 1000BASE T Cable Requirements All Category 5 UTP cables that are used for 100BASE ...

Page 65: ...Hz km 2 275 m 7 902 ft LC 50 125 micron multimode fiber 400 MHz km 2 500 m 7 1641 ft LC 500 MHz km 2 550 m 7 1805 ft LC Table 4 3 Maximum 1000BASE LX Gigabit Ethernet Cable Length Fiber Size Fiber Bandwidth Maximum Cable Length Connector 9 125 micron single mode duplex fiber N A 2 m 10 km 7 ft 6 2 miles LC Table 4 4 Maximum 1000BASE ZX Gigabit Ethernet Cable Length Fiber Size Fiber Bandwidth Maxim...

Page 66: ...tegory 5 or better 100 ohm UTP or STP 100 m 328 ft RJ 45 Table 4 6 Maximum 100BASE BX Fast Ethernet Cable Length Fiber Size Fiber Bandwidth Maximum Cable Length Connector 9 125 micron single mode simplex fiber N A 2 m 10 km 7 ft 6 2 miles SC Table 4 7 Maximum Ethernet Cable Length Type Cable Type Maximum Length Connector 100ASE T Twisted Pair Categories 3 4 5 or better 100 ohm UTP 100 m 328 ft RJ ...

Page 67: ...rly label the opposing ends of each cable Using your building s floor plans draw a map of the location of all network connected equipment For each piece of equipment identify the devices to which it is connected Note the length of each cable and the maximum cable length supported by the switch ports For ease of understanding use a location based key when assigning prefixes to your cable labeling U...

Page 68: ...MAKING NETWORK CONNECTIONS 4 10 ...

Page 69: ...ective If using a DC power conversion module check the connections between the switch and the external DC power supply If using an AC power module check connections between the switch the power cord and the wall outlet Contact your dealer for assistance Power Module LED is off 12 VDC Power module may be defective Internal power supply has failed Contact your local dealer for assistance Diag LED is...

Page 70: ...for possible defects Replace the defective adapter or cable if necessary Major LED is Red Major alarm detected One or more major system alarm s affecting traffic have occurred Check the alarm filter mask to determine potential cause s of alarm Minor LED is Amber Minor alarm detected One or more minor system alarm s affecting traffic have occurred Check the alarm filter mask to determine potential ...

Page 71: ...ment where you are sure that all the other components are functioning properly In Band Access You can access the management agent in the switch from anywhere within the attached network using Telnet a Web browser or other network management software tools However you must first configure the switch with a valid IP address subnet mask and default gateway If you have trouble establishing a link to t...

Page 72: ...TROUBLESHOOTING A 4 ...

Page 73: ... Also an RJ 45 connector must be attached to both ends of the cable Caution DO NOT plug a phone jack connector into any RJ 45 port Use only twisted pair cables with RJ 45 connectors that conform with FCC standards Caution Each wire pair must be attached to the RJ 45 connectors in a specific orientation as shown on the following pages The figure below illustrates how the pins on the RJ 45 connector...

Page 74: ...r hubs In straight through cable pins 1 2 3 and 6 at one end of the cable are connected straight through to pins 1 2 3 and 6 at the other end of the cable When using any RJ 45 port on these switches you can use either straight through or crossover cable Note Auto negotiation must be enabled for automatic MDI MDI X pinout configuration Table B 1 10 100BASE TX MDI and MDI X Port Pinouts Pin MDI Sign...

Page 75: ...port on these switches you can use either straight through or crossover cable to connect to any device type You must connect all four wire pairs as shown in the following diagram to support Gigabit Ethernet connections Figure B 2 Straight through Wiring White Orange Stripe Orange White Green Stripe Green 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 EIA TIA 568B RJ 45 Wiring Standard 10 100BASE TX Straight thro...

Page 76: ...45 port on these switches you can use either straight through or crossover cable to connect to any device type You must connect all four wire pairs as shown in the following diagram to support Gigabit Ethernet connections Figure B 3 Crossover Wiring White Orange Stripe Orange White Green Stripe 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 EIA TIA 568B RJ 45 Wiring Standard 10 100BASE TX Crossover Cable End A E...

Page 77: ...tions Also be sure that the length of any twisted pair connection does not exceed 100 meters 328 feet Table B 2 1000BASE T MDI and MDI X Port Pinouts Pin MDI Signal Name MDI X Signal Name 1 Bi directional Data One Plus BI_D1 Bi directional Data Two Plus BI_D2 2 Bi directional Data One Minus BI_D1 Bi directional Data Two Minus BI_D2 3 Bi directional Data Two Plus BI_D2 Bi directional Data One Plus ...

Page 78: ...tion Near End Crosstalk NEXT and Far End Crosstalk FEXT This cable testing information is specified in the ANSI TIA EIA TSB 67 standard Additionally cables must also pass test parameters for Return Loss and Equal Level Far End Crosstalk ELFEXT These tests are specified in the ANSI TIA EIA TSB 95 Bulletin The Additional Transmission Performance Guidelines for 100 Ohm 4 Pair Category 5 Cabling Note ...

Page 79: ...s and two cable types for backbone subsystems Horizontal 62 5 125 micron multimode two fibers per outlet Backbone 62 5 125 micron multimode or single mode TIA 568 B will allow the use of 50 125 micron multimode optical fiber in both the horizontal and backbone in addition to the types listed above All optical fiber components and installation practices must meet applicable building and safety code...

Page 80: ...CABLES B 8 ...

Page 81: ...plex only Ports 25 28 RJ 45 SFP combo port connector auto negotiation auto MDI X RJ 45 port shared with SFP transceiver slot Management Port RJ 45 connector auto MDI X RJ 45 Ports Maximum Cable Length 100 m 328 ft 10BASE T RJ 45 100 ohm UTP cable Category 3 or better 100BASE TX RJ 45 100 ohm UTP cable Category 5 or better 1000BASE T RJ 45 100 ohm UTP or STP cable Category 5 5e or 6 Alarm Port DB 1...

Page 82: ...Diagnostics Port Status link activity Weight 1 59 kg 3 5 lbs Size 44 0 x 41 5 x 6 7 cm 17 3 x 16 3 x 2 6 in Temperature Operating 20 to 65 C 4 to 149 F Storage 40 to 70 C 40 to 158 F Humidity Operating 5 to 95 non condensing Power Supply Two power modules are offered 48 VDC 36 to 72 VDC input range 1 5 A 48 VDC 100 240 VAC 100 to 240 VAC 50 60 Hz input range 1 A Power Consumption 60 Watts with two...

Page 83: ...xpansion modules Switch Features Forwarding Mode Store and forward Throughput Wire speed Flow Control Full Duplex IEEE 802 3x Half Duplex Back pressure Management Features In Band Management Web Telnet SSH or SNMP manager Out of Band Management Console port RJ 45 interface RS 232 signals Isolated management port Fast Ethernet RJ 45 Software Loading TFTP in band or XModem out of band ...

Page 84: ...EEE 802 1s Multiple Spanning Tree Protocol IEEE 802 1p Priority Tags IEEE 802 1Q Virtual LAN IEEE 802 1v Protocol based VLANs IEEE 802 3ac VLAN tagging ISO IEC 8802 3 CSMA CD Compliances CE Mark Emissions FCC Class A Industry Canada Class A EN55022 CISPR 22 Class A EN 61000 3 2 3 VCCI Class A C Tick AS NZS CISPR 22 Class A 89 336 EEC EN 300 386 2000 CFR 47 Part 15 Subpart B Immunity EN 61000 4 2 3...

Page 85: ...rts 1 10 100 1000BASE T RJ 45 SFP combo port Communication Speed 1 Gbps Communication Mode Full duplex Network Interface RJ 45 SFP slot Standards IEEE 802 3 2005 Gigabit Ethernet SFP Transceiver Support 1000BASE SX Duplex fiber Multimode LC connector 1000BASE LX Duplex fiber Single Mode LC connector 1000BASE LH Duplex fiber Single Mode LC connector ...

Page 86: ...EXTENDER MODULES C 6 ...

Page 87: ...hen 0 und 50 C 32 und 122 F und eine Feuchtigkeit innerhalb von 5 bis 95 nichtkondensierend beizubehalten In einem genügend weiten Abstand ungefähr 5 cm oder zwei Zoll von allen Seiten fur eine ausreichende Beluftung aufgestellt werden Für das Installieren die Kabelverlegung und für Wartungen und Reparaturen leicht zugänglich sein Die LED Statusanzeigedioden mussen stets klar und leicht sichtbar s...

Page 88: ...itstisch oder ein Regal montiert werden Folgend finden Sie die Montageanweisungen für jeden Positionstyp Rack Montage Beachten Sie die folgenden Faktoren bevor Sie die Rack Montage beginnen Temperatur Da die Temperatur innerhalb einer Rackeinheit höher als die Raumumgebungstemperatur sein kann stellen Sie bitte sicher dass die Rackumgebungstemperatur innerhalb des angegebenen Betriebstemperaturber...

Page 89: ...ounding the Chassis Bevor Sie den Switch anschalten erden Sie den Switch mit dem Erdboden wie im Folgenden beschrieben 1 Vergewissern Sie sich dass das Rack auf welchem der Switch montiert werden soll regelrecht geerdet ist und ETSI ETS 300 253 genügt 2 Vergewissern Sie sich dass eine gute elektrische Verbindung zum Erdungspunkt des Racks besteht keine Farbe oder isolierende Oberflächenbehandlung ...

Page 90: ...m Anschließen des DC Steckers oder Anschluß des Geräts ans Versorgungsnetz sicherstellen daß die Stromversorgung ausgeschaltet ist oder keine Verbindung dazu besteht Bemerkung 1 Um einen ausreichenden Schaltkreisschutz zwischen der Gleichstromquelle und dem Switch zu bieten sollten alle Drähte und Schaltungen mindestens das zweifache der maximalen Ladung dieses Switches führen können Siehe Power S...

Page 91: ...ie externe Gleichstromquelle 36 bis 72 V Gleichstrom mit mindestens 4 A für das 48 V Gleichstrom Stromwandlungsmodul liefern kann 2 Halten Sie zwei Drähte für jede Stromquelle die benutzt wird bereit A oder B Benutzen Sie 10 bis 24 AWG verdrillte Kupferdrähte Vergewissern Sie sich dass diese Drähte nicht in die Stromquelle gesteckt werden 3 Entfernen Sie mit einer Abstreifzange etwa 2 cm von der I...

Page 92: ...e Erdungskabel zu identifizieren Warnung Sollten die Leitungen in die falschen Löcher eingesteckt sein wird die Stromversorgung nicht richtig funktionieren und der Switch könnte beschädigt werden Figure D 1 Gleichstromanschlüsse 7 Schieben Sie jeden Draht etwa einen Zentimeter in die Öffnung des Steckers und ziehen Sie die Klammerschrauben fest Es sollte Ihnen möglich sein an den Drähten zu ziehen...

Page 93: ...en vergewissern Sie sich dass die LEDs beider Module so leuchten wie in den vorherigen Schritten angegeben Wechselstromanschluss Wenn ein universelles Wechselstrommodul im Switch installiert ist muß dem Modul externer Wechselstrom zugeführt werden So schließen Sie den Switch an eine Stromquelle an 1 Vergewissern Sie sich zunächst dass die externe Wechselstromquelle 100 bis 240 V Wechselstrom 50 60...

Page 94: ...mstatus anzeigt als auch die 12V LED die die interne Stromwandlung anzeigt leuchtet Wenn nicht überprüfen Sie noch einmal die Stromquelle und die Stromverbindungen an der Stromquelle und am Stromwandlungsmodul 5 Wenn Sie sowohl ein primäres als auch ein freigesetztes Stromwandlungsmodul installiert haben vergewissern Sie sich dass die LEDs beider Module so leuchten wie in den vorherigen Schritten ...

Page 95: ...X1 Single port 1000BASE SX Small Form Pluggable SFP mini GBIC transceiver SMCBGLLCX1 Single port 1000BASE LX Small Form Pluggable SFP mini GBIC transceiver SMCBGZLCX1 Single port 1000BASE ZX Small Form Pluggable SFP mini GBIC transceiver SMC7800Combo 1000BASE expansion module with 1 combo Gigabit Ethernet uplink port RJ 45 SFP SMC7800DC48 At least one power conversion module must be installed in t...

Page 96: ...ORDERING INFORMATION E 2 ...

Page 97: ...o pairs of Category 5 or better UTP cable 1000BASE LX IEEE 802 3z specification for Gigabit Ethernet over two strands of 50 125 62 5 125 or 9 125 micron core fiber cable 1000BASE SX IEEE 802 3z specification for Gigabit Ethernet over two strands of 50 125 or 62 5 125 micron core fiber cable 1000BASE T IEEE 802 3ab specification for Gigabit Ethernet over 100 ohm Category 5 5e or 6 twisted pair cabl...

Page 98: ...erference makes both signals unintelligible Collision Domain Single CSMA CD LAN segment CSMA CD CSMA CD Carrier Sense Multiple Access Collision Detect is the communication method employed by Ethernet Fast Ethernet or Gigabit Ethernet End Station A workstation server or other device that does not forward traffic Ethernet A network communication system developed and standardized by DEC Intel and Xer...

Page 99: ...onic Engineers IEEE 802 3 Defines carrier sense multiple access with collision detection CSMA CD access method and physical layer specifications IEEE 802 3ab Defines CSMA CD access method and physical layer specifications for 1000BASE T Gigabit Ethernet Now incorporated in IEEE 802 3 2005 IEEE 802 3u Defines CSMA CD access method and physical layer specifications for 100BASE TX Fast Ethernet Now i...

Page 100: ...about the device Modal Bandwidth Bandwidth for multimode fiber is referred to as modal bandwidth because it varies with the modal field or core diameter of the fiber Modal bandwidth is specified in units of MHz per km which indicates the amount of bandwidth supported by the fiber for a one km distance Network Diameter Wire distance between two end stations in the same collision domain Redundant Po...

Page 101: ...d IP as the network layer protocol UTP Unshielded twisted pair cable Virtual LAN VLAN A Virtual LAN is a collection of network nodes that share the same collision domain regardless of their physical location or connection point in the network A VLAN serves as a logical workgroup with no physical barriers allowing users to share information and resources as though located on the same LAN ...

Page 102: ...GLOSSARY Glossary 6 ...

Page 103: ...esive feet attaching 3 6 air flow requirements 3 1 alarm interface port 1 5 alarm port pin assignments 3 15 applications downlink fiber connections 2 3 management connections 2 5 private VLAN connections 2 6 uplink connections 2 4 B brackets attaching 3 4 buffer size C 1 C cable Ethernet cable compatibility 3 2 labeling and connection records 4 9 cleaning fiber terminators 4 5 compliances EMC C 4 ...

Page 104: ...ED indicators Diag 1 7 Fan Fail 1 7 Major 1 7 Minor 1 7 port 1 7 power 1 7 problems A 1 location requirements 3 1 M management agent 1 2 features 1 12 C 3 out of band 1 3 SNMP 1 2 web based 1 3 management port 1 4 media expansion module 1 10 mounting the switch on a desktop or shelf 3 5 multimode fiber optic cables 4 4 N network connection examples 2 2 connections 4 1 O optional module installatio...

Page 105: ... 1 5 transceiver connections 4 4 single mode fiber optic cables 4 4 site selelction 3 1 SNMP agent 1 2 specifications compliances C 4 environmental C 2 media extender module C 5 physical C 1 power C 2 standards IEEE C 4 status LEDs 1 6 surge suppressor using 3 1 switch architecture 1 2 T troubleshooting in band access A 3 power and cooling problems A 3 switch indicators A 1 Telnet A 3 twisted pair...

Page 106: ...INDEX Index 4 ...

Page 107: ......

Page 108: ...0 41 38 01 58 Italy 39 0 335 5708602 Fax 39 02 739 14 17 Benelux 31 33 455 72 88 Fax 31 33 455 73 30 Central Europe 49 0 89 92861 0 Fax 49 0 89 92861 230 Nordic 46 0 868 70700 Fax 46 0 887 62 62 Eastern Europe 34 93 477 4920 Fax 34 93 477 3774 Sub Saharian Africa 216 712 36616 Fax 216 71751415 North West Africa 34 93 477 4920 Fax 34 93 477 3774 CIS 7 095 7893573 Fax 7 095 789 35 73 PRC 86 10 6235 ...