56-VV5QC*1-TFL33-C

 

2 Specifications (continued) 

56-VQC4000 (56-EX500) 

 

Figure 7 

 
 

56-VQC4000 (56-EX250) 

 

Figure 8 

 
 

3 Installation 

3.1  Installation 

 

• 

Do not install the product unless the safety instructions have been read 
and understood. 

 

 

• 

Protect  from  impacts  using  an  ATEX  enclosure  suitable  for 
impacts. 

 

3.2  Environment 

 

• 

Do  not  use  in  an  environment  where  the  product  is  directly  exposed  to 
corrosive gases, chemicals, salt water, water or steam. 

• 

Do not use in an explosive atmosphere, except Zone 2/22. 

• 

The  product  should  not  be  exposed  to  prolonged  sunlight.  Use  a 
protective cover. 

• 

Do not mount the product in a location where it is subject to excessive 
vibrations and/or impacts. 

• 

Do not mount the product in a location exposed to radiant heat. 

• 

Remove emissive heat. 

• 

Employ suitable protective measures in locations where there is contact 
with water droplets, oil or welding splatter, etc. 

• 

When the solenoid valve is mounted in a control panel or is energised for 
a  long  time,  make  sure  the  ambient  temperature  is  within  the  valve 
specification range. 

 

3.3  Piping 

 

• 

Before piping make sure to clean up chips, cutting oil, dust etc. 

• 

When installing piping or fittings, ensure sealant material does not enter 
inside the port. When using seal tape, leave 1.5 to 2 threads exposed on 
the end of the pipe/fitting.  

• 

Install piping so that it does not apply pulling, pressing, bending or other 
forces on the valve body. 

3 Installation (continued) 

• 

Tighten fittings to the specified tightening torque shown in Table 1. 

Thread 

Tightening Torque N•m 

M5 

By hand + 1/6 turn with a wrench (1/4 turn for miniature fittings) 

Rc 1/8 

7 to 9 

Rc 1/4 

12 to 14 

Rc 3/8 

22 to 24 

Rc 1/2 

28 to 30 

Rc 3/4 

28 to 30 

Table 1 

 

3.4  Electrical Connection 

 

• 

The manifold has negative common (-COM). 

• 

Avoid  mis-wiring,  as  this  can  cause  malfunction,  damage  and 
combustion to the product. 

• 

Use  voltage  that  is  within  ±10%  of  the  rated  voltage.  Application  of 
incorrect voltage may cause malfunction or damage. 

• 

To prevent noise and surge in signal lines, keep all wiring separate from 
power  lines  and  high  voltage  lines.  Otherwise  this  can  cause 
malfunction. 

• 

Use electrical circuits that do not generate chattering in their contacts. 

• 

Do not bend or pull cables repeatedly. 

 

 

• 

Disconnect  power  supply  before  removing  or  making  electrical 
connections 

 
 
 
 
 
 
 
 

Multiple connector wiring (M-Kit) 

 

Figure 9

 

 

3 Installation (continued) 

Terminal block wiring (T-Kit) 

 

Figure 10 

3.5  Mounting 

 

• 

Never remove a valve from the manifold when energised. 

• 

Never  remove  terminal  box  cover  when  power  is  connected  to  the 
manifold. 

• 

Never  disconnect  or  reconnect  cables  or  connectors  when  power  is 
connected to the manifold. 

• 

Install 56-VQC valves only. 

• 

Install  56-VV5QC  manifolds  only,  as  it  has  an  integrated  power  saving 
circuit. 

 

56-VQC1000/2000 Valve mounting: 

 

Figure 11 

 

Removal procedure: 

• 

Loosen clamp screws until they turn freely (they do not come out). 

• 

Remove  the  solenoid  valve  from  Clamp  B  by  lifting  the  coil  side  of  the 
valve, while pushing on the screw top. 

3 Installation (continued) 

Mounting procedure: 

• 

Push the clamp screw. Clamp A now opens. 

• 

Insert the end plate hook of the valve into Clamp B from an angle. 

• 

Push  the  valve  down  into  place  (when  the  clamp  screw  is  released, 
Clamp A will lock). 

 

56-VQC4000 Valve mounting: 

 

Figure 12 

Removal procedure: 

• 

Loosen mounting screws until they turn freely. 

• 

Remove  the  solenoid  valve  from  Clamp  B  by  lifting  the  coil  side  of  the 
valve first. 

 

Mounting procedure: 

• 

Push the coil side of the valve into the connector on the manifold. 

• 

Tighten the mounting screws to torque 0.8 to 1.2 N•m. 

 

 

• 

Ensure all gaskets are present before mounting valves. 

• 

Do not let foreign matter stick to gaskets or sealing faces of the valve to 

avoid air leaks 

 

3.6  Lubrication 

 

• 

SMC products have been lubricated for life at manufacture, and do not 
require lubrication in service. 

• 

If a lubricant is used in the system, use turbine oil Class 1 (no additive), 
ISO  VG32.  Once  lubricant  is  used  in  the  system,  lubrication  must  be 
continued  because  the  original  lubricant  applied  during  manufacturing 
will be washed away. 

 

4 Settings 

4.1  Manual Override 

 

• 

Since  connected  equipment  will  operate  when  the  manual  override  is 
activated, confirm that conditions are safe prior to activation. 

 

Non-locking push type (tool required) 

• 

Push  down  the  manual  override  button  with  a  small  screwdriver,  etc. 
until it stops. 

• 

The manual override will return when released. 

 

 

Figure 13 

Slotted locking push type (tool required) 

• 

Push down the manual override button with a small flat head screwdriver 
until it stops and turn 90° clockwise to lock. 