background image

Summary of Contents for -12MCC FICHE

Page 1: ......

Page 2: ...19 Rack mount 12 Slot Standalone Media Converter Chassis User s Manual December 2003 ...

Page 3: ... Package Contents 2 Hardware Description 3 Product Overview 3 Product Outlook 4 Installation 5 Installing the brackets 5 Affixing brackets 6 Installing the converter 7 Power Supply 11 Rack Kit 13 LEDs Indicators 15 Cooling 17 Technical Specifications 19 Compliances i Legal Information and Contacts v ...

Page 4: ... Usage In this guide the term Chassis first letter upper case refers to your 19 Rack mount 12 slot Standalone Media Converter Chassis and chassis first letter lower case refers to other chassis Features Supports two load sharing hot swappable power supplies Three high volume cooling fans ensure perfect operating environment Status panel with fan and slot power status LEDs Supports slot power isola...

Page 5: ...ice Complex Banks Military etc High quality 19 Rack mount Chassis Supports up to 12 media converters Package Contents One 12 slot Media Converter Chassis One power supply One power supply cable 19 rack mounting kit 12 blank panels fitted 24 Converter mounting panels Four self adhesive pads Spare screws Spare fuses One user s manual ...

Page 6: ...ing the Chassis operation offering total efficiency maximum redundancy and minimum down time Each converter is supplied from a common shared power bus but as an added precaution each is individually protected in the event of a problem on the bus or from the power supply Each converter can also be changed without powering down Functionality The Chassis was carefully designed to offer a lifetime of ...

Page 7: ...Hardware Description 4 Product Outlook Front View with 12 blank slots and two power supplies Rear View showing 3 cooling fans Side View with rack mount assembly fitted ...

Page 8: ...s first and then the Chassis or you can install the Chassis first and then the converters We recommend that you do the latter as it is more convenient Installing the brackets All the converters are made using a standard case This allows it to fit into the Chassis with ease The converters can be mounted directly into the Chassis without using the supplied brackets but we strongly advise against thi...

Page 9: ...e side panels on the converter Step 2 Place the converter and brackets on a flat horizontal surface as illustrated above Secure the brackets by replacing the screws Ensure that the rails are flush mounted with the underside of the converter The converter is now ready for loading into the Chassis ...

Page 10: ...rect mating of the power connector Choose an available slot and align the converter so that it fits between the upper and lower guide rails Warning Always ensure that the converter s power socket is positioned at the base of the Chassis Warning Never force the converter into the Chassis check power socket position and alignment 12 slot Media Converter Chassis If necessary you may gently move the c...

Page 11: ... is built to established EIA Standards and as such will fit into any 19 EIA designed rack Refer to the section Rack Kit Wall Mount The Chassis can be mounted separately on a wall with the use of a shelf This should be securely mounted on a suitable structure and must be able to hold at least 15 kg The shelf should also be big enough to accommodate the Chassis whilst still offering space for adequa...

Page 12: ...ing the converter 9 Desktop The Chassis can be situated on any suitable desktop Simply attach the adhesive pads to the base of the Chassis and position where suitable again keep adequate space for ventilation ...

Page 13: ...two power supplies is recommended During 2 power operation both power supplies will be switched on and will share the currant load between them In the event that a power supply should fail the other supply will take 100 of the load This will happen instantaneously and will have no adverse effects on the operation of the Chassis Similarly if a power supply is removed for servicing it can be switche...

Page 14: ...mply undo the securing screws and then pull the power supply unit out from the Chassis by the handles Warning Always exercise Caution when removing supplies Always switch Power Supply off before removing Always remove Power Cable from Supplies before removing Do not touch Power Supply components after removal they may hold residual electrical charges ...

Page 15: ...e fitted to the Chassis via six screws It is strongly recommended that you use all six screws supplied with the Chassis This will ensure that stress is not unnecessary endured by the Chassis or the brackets Each bracket has EIA standard mounting holes and is symmetrical so that either bracket can be used on either side of the Chassis ...

Page 16: ...onnection stops Each slot has its own protection system that isolates each converter from any problems that might occur with either the power supplies or another faulty converter This offers the best possible protection to your investment in the various media converters Fan Indicator LED s These should illuminate under normal operating conditions Slot Power LED s These will illuminate when convert...

Page 17: ...itoring Panel on the front of the Chassis Even with only one fan working the Chassis is capable of operating under normal operating temperatures For the purpose of cleaning the Fan panel assembly can be removed for periodic maintenance Switch both power supplies off and remove the six securing screws Disconnect the three power cables supplying DC to the fans The fans can then be cleaned with a dry...

Page 18: ...ted fans Dimension 440 x 290 x 133 mm L x W x H EIA 3U Weight 7 6 kg with one power supply 13 kg loaded with 12 standalone converters Power Supply Specs for AC AC input 100 240V AC 47 63Hz DC Output Norm 12V Min 11 88V Max 12 12V 75Watts Load Min OA Full 6 4A Total Reg 1 0 Rip 120mV Load 2 0 Line 0 5 Overload Protection All outputs protected against short circuit conditions automatic recovery Over...

Page 19: ... Reg 2 0 Rip 120mV Load 2 0 Line 1 0 Overload Protection Output protected against short circuit conditions automatic recovery Over volts Protection Output level exceeding 13 2V causes shutdown automatic recovery Temperature Operation 0 C 50 C Storage 55 C 85 C Fans Specs Speed 2510 rpm 250 Delivery 42 5ft3 Per Min Noise Level 36 5dB A each fan Temperature Operation 10 C 50 C Storage 40 C 70 C Bear...

Page 20: ...ollowing measures Reorient the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help EC Conformance Declaration Class A SMC contact for these products in Europe is SMC Networks Europe Edificio Conata II Cal...

Page 21: ...1996 0 15 80 MHz with 1 kHz AM 80 Modulation 3 V m Power frequency magnetic field immunity test according to EN 61000 4 8 1993 1 A m at frequency 50 Hz Voltage dips short interruptions and voltage variations immunity test according to EN 61000 4 11 1994 95 Reduction 10 ms 30 Reduction 500 ms 95 Reduction 5000 ms LVD EN 60950 A1 1992 A2 1993 A3 1993 A4 1995 A11 1997 MDD IEC 60601 1 Industry Canada ...

Page 22: ... daß diese Öffnungen nicht abgedeckt werden 8 Beachten Sie beim Anschluß an das Stromnetz die Anschlußwerte 9 Verlegen Sie die Netzanschlußleitung so daß niemand darüber fallen kann Es sollte auch nichts auf der Leitung abgestellt werden 10 Alle Hinweise und Warnungen die sich am Gerät befinden sind zu beachten 11 Wird das Gerät über einen längeren Zeitraum nicht benutzt sollten Sie es vom Stromne...

Page 23: ...gefallen und oder das Gehäuse ist beschädigt f Wenn das Gerät deutliche Anzeichen eines Defektes aufweist 15 Stellen Sie sicher daß die Stromversorgung dieses Gerätes nach der EN 60950 geprüft ist Ausgangswerte der Stromversorgung sollten die Werte von AC 7 5 8 V 50 60 Hz nicht über oder unterschreiten sowie den minimalen Strom von 1 A nicht unterschreiten Der arbeitsplatzbezogene Schalldruckpegel...

Page 24: ...s within 30 days of purchase from SMC or its Authorized Reseller Registration can be accomplished via the enclosed product registration card or online via the SMC web site Failure to register will not affect the standard limited warranty The Limited Lifetime warranty covers a product during the Life of that Product which is defined as a period of 5 years from the date of purchase of the product fr...

Page 25: ...ANTIES OR CONDITIONS OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE SMC NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO ASSUME FOR IT ANY OTHER LIABILITY IN CONNECTION WITH THE SALE INSTALLATION MAINTENANCE OR USE OF ITS PRODUCTS SMC SHALL NOT BE LIABLE UNDER THIS WARRANTY IF ITS TESTING AND EXAMINATION DISCLOSE THE ALLEGED DEFECT IN THE PRODUCT DOES NOT EXIST OR WAS CAUSED BY CUSTOMER...

Page 26: ...om are provided on www smc europe com section support Firmware and Drivers For latest driver technical information and bug fixes please visit www smc europe com section support Contact SMC Contact details for your relevant countries are available on www smc europe com and www smc com Statement of Conditions In line with our continued efforts to improve internal design operational function and or r...

Page 27: ...as been adviced of the possiblity of such damages Copyright Information furnished by SMC Networks Inc SMC is believed to be accurate and reliable However no responsibility is assumed by SMC for its use nor for any infringements of patents or other rights of third parties which may result from its use No license is granted by implication or otherwise under any patent or patent rights of SMC SMC res...