Installation & Maintenance Manual

Analogue Input Module

Type EX245-AX1/2-X38

EX245-TFK53GB

Names and Functions of Individual Parts

LED indicators

Unit side connection

Module side connection

Sensor connection
1 x M12, 8-way socket

STATU

S

DO

DI0

DI1

ANALO

G INPU

T

Parts and description

•Sensor connection

To connect the sensor.

•Unit side connection 

To connect to the SI unit or the previous module.

•Module side connection

To connect to the next module or the End plate.

•LED indicators

To indicate the status of the sensors.

Installation

ERR

Description

OFF

No error.

Red ON

Short circuit or over/under-voltage is detected.

ANALOG INPUT

ERR

LED indicators
•EX245-AX1-X38

Designation

Description

STATUS

Analogue input current is below the permissible
level (< 3.2 mA).

OFF

Analogue input current is within the permissible
range (3.2 to 21.5 mA).

ANALOG INPUT

STATUS

DO

DI0

DI1

•EX245-AX2-X38

Green ON

Red

flashing

Red ON

Analogue input current is above the permissible
level (> 21.5 mA).

Short circuit is detected.

DO

OFF

Digital output is not activated.

Green ON Digital output is activated.

DI0

OFF

Digital input 0 is not activated.

Green ON Digital input 0 is activated.

DI1

OFF

Digital input 1 is not activated.

Green ON Digital input 1 is activated.

Connect the modules with the 2 modular adaptor assemblies and a joint
assembly.

1. 1 x Joint assembly
2. 2 x Modular adaptor assembly (torque=1.3 Nm)

2

1

2

0

2

4

6

1

3

5

7

Caution 

•For a protection rating of IP65 to be ensured, modular adaptor assemblies

and joint assembly must be correctly installed between each module.

•To prevent the modules and assemblies being damaged, apply the

recommended tightening torque. 

Wiring

1

2

3

4

5

View of connector (module side)

1

2

4

3

5

6

7

8

Pin allocation of the M12, 8-way sockets connectors as shown in the
following table:

Pin allocation of the connector for EX245-AX1-X38

Caution 

•To prevent damage, all power for the SI Unit and modules must be turned

off (i.e. de-energized) before the modules are installed or removed.

•For a protection rating of IP65 to be ensured, sockets which are not used

must be closed with M12 covering caps.

•For a protection rating of IP65 to be ensured, all covering caps must be

screwed down correctly after all wiring and settings have been completed.

6

7

8

Pin

1

2

3

4

5

View of connector (module side)

1

2

4

3

5

6

7

8

Pin allocation of the connector for EX245-AX2-X38

6

7

8

Troubleshooting

No.

Remedy

1

2

•Check the wiring

and pin numbers.

•Check the sensor.

Correct 
measured value
cannot be
received from
sensor.

Problem

ERR indicator
red light is ON.

Check the wiring and
pin numbers.

Check the supply for
the sensors.

Check the sensor.

1

2

Check the sensor.

The identifiers of
EX245-AX2-X38
are not present
in the DP 
master’s
software.

Check the version of
GSD file.

Check the wiring and
pin numbers.

Check the supply for
the sensors.

Troubleshooting for EX245-AX2-X38

Correct 
measured value
cannot be
received from
sensor.

3

Check the load.

Check the wiring and
pin numbers.

Check the supply for
the sensors.

4

STATUS 
indicator red
light is ON.

•Check the wiring

and pin numbers.

•Check the sensor.

5

STATUS 
indicator is OFF.

•Check the wiring

and pin numbers.

•Check the sensor.

6

STATUS 
indicator red
light is flashing.

•Check the wiring

and pin numbers.

•Check the sensor.

Specifications

Refer to the operation manual for this product.

Outline with Dimensions (in mm)

Refer to the operation manual for this product.

The load is not
operating.

Connector has a short
circuit.

Analogue input current is
below the permissible
level (< 3.2 mA).

Analogue input current is
above the permissible
level (> 21.5 mA).

Possible cause

Sensor is faulty.

The version of GSD is
not compatible.

Incorrect wiring.

US1 is not present or
below the dropout level
(< 17 VDC approx).

Incorrect wiring.

The load is faulty.

US1 is not present or
below the dropout level
(< 17 VDC approx).

Possible cause

•Connector has a short

circuit.

•Over-voltage

(> +11 V approx).

•Under-voltage

(< -11 V approx).

Incorrect wiring.

US1 is not present or
below the dropout level
(< 17 VDC approx).

Sensor is faulty.

Troubleshooting for EX245-AX1-X38

Allocation

N.C.

24 V (US1)

0 V (US1)

0 V (US1)

AI (analogue input signal)

N.C.

N.C.

N.C.

Allocation

DI (input signal "1")

24 V (US1)

0 V (US1)

N.C.

DO (output signal)

Analogue input (+)

Analogue input (-)

DI (input signal "0")

Problem

No.

Remedy

Pin

Safety Instructions

These safety instructions are intended to prevent hazardous situations
and/or equipment damage.
These instructions indicate the level of potential hazard with the labels of
"Caution", "Warning" or "Danger". They are all important notes for safety
and must be followed in addition to International standards (ISO/IEC),
Japan Industrial Standards (JIS) and other safety regulations.
To ensure safety of personnel and equipment the safety instructions in
this manual and the product catalogue must be observed, along with
other relevant safety practices.

Operator error could result in serious injury or loss
of life.

In extreme conditions, there is a possibility of 
serious injury or loss of life.

Operator error could result in injury or equipment
damage.

•After maintenance is complete, perform appropriate functional

inspections.

Stop operation if the equipment does not function properly.
Safety cannot be assured in the case of unexpected malfunction.

•Provide grounding to assure the safety and noise resistance of the

SI unit.

Individual grounding should be provided close to the product with a
short cable.

Warning

•Do not disassemble, modify (including changing of printed circuit

board) or repair.

An injury or failure can result.

•Do not operate the product outside of the specifications.

Do not use for flammable or harmful fluids.
Fire, malfunction, or damage to the product can result.
Verify the specifications before use.

•Do not operate in an atmosphere containing flammable or

explosive gases.

Fire or an explosion can result.
This product is not designed to be explosion proof.

•If using the product in an interlocking circuit:

•Provide a double interlocking system, for example a mechanical

system.

•Check the product regularly for proper operation.

Otherwise malfunction can result, causing an accident.

•The following instructions must be followed during maintenance:

•Turn off the power supply.
•Stop the air supply, exhaust the residual pressure and verify that

the air is released before performing maintenance.

Otherwise an injury can result.

Caution

Contact

AUSTRIA

(43) 2262 62280 

NETHERLANDS

(31) 20 531 8888 

BELGIUM

(32) 3 355 1464 

NORWAY

(47) 67 12 90 20 

CZECH REP.

(420) 541 424 611 

POLAND

(48) 22 211 9600 

DENMARK

(45) 7025 2900 

PORTUGAL

(351) 21 471 1880

FINLAND

(358) 207 513513 

SLOVAKIA

(421) 2 444 56725 

FRANCE

(33) 1 6476 1000 

SLOVENIA

(386) 73 885 412

GERMANY

(49) 6103 4020 

SPAIN

(34) 945 184 100 

GREECE

(30) 210 271 7265 

SWEDEN

(46) 8 603 1200 

HUNGARY

(36) 23 511 390 

SWITZERLAND

(41) 52 396 3131 

IRELAND

(353) 1 403 9000 

UNITED KINGDOM

(44) 1908 563888 

ITALY

(39) 02 92711

URL http://www.smcworld.com (Global) http://www.smceu.com (Europe)

Specifications are subject to change without prior notice from the manufacturer. 
© 2009 SMC Corporation All Rights Reserved.