background image

 

USN3se, MX3se-3I3P - Datasheet V1R01c 

 

© 2016, Smartware 

CONFIDENTIAL

 

U

LTRA

S

MART

 

T

RIPLE 

D

UAL

 

I

NTERFACES FOR

 

PRODUCTION

 

(USN3se, MX3se-3I3P) 

 

Industrial equipment to personalize contact and contactless smart cards or modules. 

 

 

 

 

 

 

 

 

Datasheet V1R01c 

Date: December 2016 

Summary of Contents for ULTRASMART MX3se-3I3P

Page 1: ...et V1R01c 2016 Smartware CONFIDENTIAL 1 ULTRASMART TRIPLE DUAL INTERFACES FOR PRODUCTION USN3se MX3se 3I3P Industrial equipment to personalize contact and contactless smart cards or modules Datasheet...

Page 2: ...an imitation whatever mean is used Only reproductions strictly reserved for the private use of the purchaser and not intended to be used collectively are authorized So are the short quotations justif...

Page 3: ...2 3 Hardware measurements 8 3 3 Contactless interfaces 9 4 Technical characteristics 10 4 1 Mechanical layout 10 4 2 Front panels 11 4 3 Physical interfaces 12 4 3 1 Connectors 12 4 3 2 Configuration...

Page 4: ...Electrostatic Discharge ETU Elementary Time Unit FDT Frame Delay Time FSCI Frame Size Card Integer FSDI Frame Size Device Integer FWT Frame Waiting Time HCI Host Controller Interface LLC Logical Link...

Page 5: ...ock frequency up to 20 MHz Communication protocol parameters Contactless interfaces features Supported protocols ISO IEC 14443 2 3 4 ISO IEC 15693 2 3 MasterCard PayPass Sony FeliCaTM NXP MIFARETM and...

Page 6: ...LD C1 C8 Contactless Interface RF aodem CLX Flash RAa DAC Voltage Control Continuity Test DAC ADC Contacts Switchs SWt SCX aStX FPID progaming port Ethernet Switch INTERFACE A INTERFACE B INTERFACE C...

Page 7: ...plication handles the standard ISO7816 smart card protocol Its rich interface allows to perform fast communication exchanges and to subtly configure all protocol parameters Non exhaustive list of soft...

Page 8: ...from the reader s contact interface to the smart card pads Measure the serial resistor due to cable test head or deficient contact pin for each smart card pad Check the smart card clamp diodes betwee...

Page 9: ...software features and configuration parameters Adjustable carrier field strength Communication bit rate up to 848 kbps Protocol timing specific parameters such as EGT FWT FDT SFGT etc Protocol commun...

Page 10: ...6 5 50 2 00 50 90 1 2 3 4 101 60 152 30 A B C C B A 13 08 19 42 5 50 1 2 3 4 InterIO PowerCom A 1 2 1 2 2 50 196 10 107 10 45 00 3 20 207 50 3 57 5 55 1 50 5 50 2 70 A1 M S L4 L1 L2 L3 S4 L5 S5 15 00...

Page 11: ...dth USN3se 20 3 mm 4 TE Width MX3se 3I3P 40 mm 8 TE Weight 360 g Components on bottom side are lower than 2 mm The fixing attachment holes and side strips are connected to the USN3se and MX3se 3I3P el...

Page 12: ...nnectors provide signals of the contact interfaces The following table describes the pinout for all interfaces PIN NAME TYPE DESCRIPTION 1 CC3 I O C3 smart card contact CLK 2 CC5 GND C5 smart card con...

Page 13: ...ano A C1 L1Rx Line 1 RS232 receive US Nano A B4 Node0 Node Base bit 0 C4 Node1 Node Base bit 1 A5 Node2 Node Base bit 2 B5 Node3 Node Base bit 3 C5 Node4 Node Base bit 4 A6 Node5 Node Base bit 5 B6 No...

Page 14: ...de Base bit 7 B13 ETH_BP_2P Ethernet Pair 2 1 B14 ETH_BP_2M Ethernet Pair 2 1 B15 ETH_BP_3P Ethernet Pair 3 1 B16 ETH_BP_3M Ethernet Pair 3 1 4 3 2 Configuration and address switches 4 3 2 1 SWCFG Thi...

Page 15: ...base value from J30 and SWCFG and a specific offset from SWX switch US Nano Node interface X Node base Node offset interface X PIN NAME DESCRIPTION 1 Node offset b0 Node offset bit 0 2 Node offset b1...

Page 16: ...us ON if Safe Mode is activated M Mono Mode Status ON if Mono Mode is activated L1 LA US Nano A Ethernet link status ON if link is established L2 LB US Nano B Ethernet link status ON if link is establ...

Page 17: ...perating environment 0 C to 40 C 4 4 1 Power Supply An USN3se or MX3se 3I3P assembly shall be powered by a 12 Volt 3 Amp Direct Current DC power supply POWER SUPPLY TYPICAL PRECISION Rating Voltage 12...

Page 18: ...Mode 200 mA VOH Vcc 0 1 V Vcc VOL 0 V 0 1 V VIH 0 8 x Vcc VIL 0 55 V Current limitation 1 65 Vcc 1 95 4 mA 2 30 Vcc 2 70 8 mA 3 00 Vcc 3 60 24 mA 4 50 Vcc 5 50 32 mA Clock ISO Mode 1 MHz 20 MHz C5 im...

Page 19: ...ecision RF Offset 400 mV RF Signal peak to peak R 2 Vpp 20 Vpp 2 0 05 Vpp RF Signal power R 50 250 mW 24 dBm RF Output Impedance 50 5 Current limitation Short circuit current R 0 RMS 150 mA Recommende...

Page 20: ...y to persons follow these instructions All maintenance and servicing of this device must be performed in a safe area away from hazardous locations Disconnect all power before servicing Use an earthed...

Page 21: ...uipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense This device USN3se and MX3se 3I3P models co...

Page 22: ...ease send an email to support smartware fr For ordering information please send an email to sales smartware fr 7 REVISION HISTORY VERSION DATE AUTHOR CHANGES V1R01c December 2016 DM Editorial correcti...