Safety Light Curtain – C4 compact ME Series 

 

Installation Guide

 

 

File Number: CD1011               

page 42                                                                            Date: 12 April, 2017

 

Appendix 3 – Mirrors 

Reflector mirrors can be provided enabling two or three sides of a machine to be safeguarded 

with, what is effectively a single light curtain. 

 

When mirrors are employed it is essential that the mounting of the transmitter unit, receiver unit 

and mirrors themselves are sufficiently rigid.    Alignment becomes increasingly critical as the 

range and number of mirrors increase.    Mirrors cause a reduction in optical efficiency, reducing 

the effective range.    A guide to the practicality of using mirrors is given below. 

 

Range of the   

light curtain 

Maximum range   

through 1 mirror 

Maximum range   

through 2 mirrors 

3m - 10m 

8m 

6m 

 

Total Light Path 

1 Mirror 

2 Mirror 

2m Easy 

Easy 

4m Easy 

Medium 

6m Medium 

Hard 

8m Hard 

Not 

Feasible 

The angle of the infrared beams from the light curtain striking the reflective surface must be 

within defined limits as per the drawings above. 

 

Perimeter curtains will be easier to align, curtains over 900mm may be more difficult to align.   

Check with the Smartscan technical department prior to ordering for a particular application, 

[email protected], Tel: 886 - 4 - 23598885, Fax: 886 - 4 – 23599423 

 

 

 

Summary of Contents for C4 compact ME Series

Page 1: ...C4 compact ME SERIES SAFETY LIGHT CURTAINS INSTALLATION GUIDE MACHINERY SAFETY SYSTEMS...

Page 2: ...duct The Installation Sheet and Installation Guide can be downloaded from our web site at www smartscan com tw The C4 compact ME series Safety Light Curtain Installation Guide CD1011 is subject to cha...

Page 3: ...Supply 16 Automatic Reset 16 External Device Monitoring EDM 17 Safety Outputs OSSD1 and OSSD2 17 Communication Link 18 Figure H Identification Labels 19 Figure I Status and Diagnostic Indication 20 R...

Page 4: ...g Remove all packaging material and retain it Locate and keep the delivery note Inspect all items for transit damage Match goods supplied to those specified on the delivery note Keep the Installation...

Page 5: ...d at the ends of the safety light curtain as shown above The mounting bracket may be fixed at 90 degrees with a 5 adjustment Use 4mm bolts for mounting and ensure they are fixed so as to prevent any m...

Page 6: ...safety light curtain s overall length including mounting brackets fixing centres and detection zone width The detection zone width DZ DZ2 or protected height is needed to select the appropriate lengt...

Page 7: ...C and 50 C Vibration Frequency 55Hz Max Movement 0 35mm Do not use equipment in explosive atmospheres contact the manufacturer for further advice Detection Zone width DZ The detection zone width or p...

Page 8: ...tain is capable of satisfying the range requirement for the particular application it is being used for Reset Location Reset devices must be located such that the danger area can be seen to be clear o...

Page 9: ...is not directed towards the Perspex window of the receiver unit RX Extraneous sources would include infrared sensors infrared remote controls scanning systems or sunlight 3 Ensure the mounting positio...

Page 10: ...eing guarded 4 Ensure the light curtain transmitter TX and receiver RX units are mounted accurately in line with each other and are both perpendicular and parallel to each other within the parameters...

Page 11: ...Safety Light Curtain C4 compact ME Series Installation Guide File Number CD1011 page 11 Date 12 April 2017 Figure F Electrical Connections Reset Mode Manual Latched...

Page 12: ...perator first checking that the dangerous area is clear of personnel and therefore safe The reset switch must also be located so that the operator cannot reset the light curtain from inside the danger...

Page 13: ...head should be connected via a normally closed NC contact of the external Final Switching Device FSD being monitored The other side of the contact is connected to 24V DC If the EDM is not being used t...

Page 14: ...via DATA Link The Violet wire from the Transmitter TX head cable must be connected to the Violet wire from the Receiver RX head cable Warning The Data wires are communication links and have DATA Link...

Page 15: ...Safety Light Curtain C4 compact ME Series Installation Guide File Number CD1011 page 15 Date 12 April 2017 Figure G Electrical Connections Auto Reset Mode...

Page 16: ...safety outputs OSSDs Removing the blockage from the sensing field of the light curtain will re activate and turn on the safety outputs OSSDs The configuration of the safety light curtain in the auto...

Page 17: ...itching device FSD being monitored The other side of the contact s is connected to 24V DC If the EDM is not being used the Green wire must be connected to a permanent 24V DC L The bottom yellow LED in...

Page 18: ...via DATA Link The Violet wire from the Transmitter TX head cable must be connected to the Violet wire from the Receiver RX head cable Warning The Data wires are communication links and have DATA Link...

Page 19: ...Series Installation Guide File Number CD1011 page 19 Date 12 April 2017 Figure H Identification Labels Examples are shown below of the identification labels that are affixed to the bottom of the tran...

Page 20: ...light curtain and in fault diagnosis Receiver RX Status Indicators GREEN LED on Light curtain safety reset has been initiated and the OSSDs are in the on state only when the light curtain detection z...

Page 21: ...st The C4 compact ME series signal strength is monitored from the bottom block of 3 beams those nearest the cable entry Fault Diagnosis The display panel also provides 6 different error codes E0 E1 E2...

Page 22: ...upside down e g with the connection cables at the top furthest away from the floor rather than the bottom nearest the floor This allows the user to read the TX display even when the light curtain is...

Page 23: ...tors Block Beam blocked The Block LED is a Red indicator Clear Light curtain active The Green Indicators help the operator to see the current operating status of the safety light curtain Green lights...

Page 24: ...ain must be followed by testing to check the system is still working correctly Regular function checking of the safety light curtain as well as at initial installation is required as part of the test...

Page 25: ...utput switches should only turn OFF as the test piece totally obscures each beam in the light curtain Ensure that while the test piece is obscuring each beam the output switches are OFF Maintenance Th...

Page 26: ...lation Sheet provided paying particular attention to the information provided in Fig E o Refer to Fig J for test and maintenance procedures o Every 24 hours carry out tests as indicated in Fig J o Eve...

Page 27: ...ure If a fault occurs that cannot be resolved or the equipment is damaged return the equipment to the nearest Smartscan distributor or Smartscan TW Ltd Indicate the nature of the fault and the symptom...

Page 28: ...el List Fig M shows the C4 compact ME series safety light curtain model numbers with their corresponding number of Infrared beams detection zone width DZ DZ2 fixing centres CTR CTR2 overall length L2...

Page 29: ...ad zone C4 series Standard dead zone Note Main unit M and extender unit E be connected by cables Depend on customer s order We will give a total model No and note separately its M E unit The total len...

Page 30: ...ngth C mm Assembly Length D mm C4B 6M 6 180 183 218 246 C4B 12M 12 330 333 368 396 C4B 18M 18 480 483 518 546 C4B 24M 24 630 633 668 696 C4B 30M 30 780 783 818 846 C4B 36M 36 930 933 968 996 C4B 42M 4...

Page 31: ...m Assembly Length D mm C4B 6LM 6 190 183 218 246 C4B 12LM 12 340 333 368 396 C4B 18LM 18 490 483 518 546 C4B 24LM 24 640 633 668 696 C4B 30LM 30 790 783 818 846 C4B 36LM 36 940 933 968 996 C4B 42LM 42...

Page 32: ...ngth C mm Assembly Length D mm C4B 6E 6 180 172 207 235 C4B 12E 12 330 322 357 385 C4B 18E 18 480 472 507 535 C4B 24E 24 630 622 657 685 C4B 30E 30 780 772 807 835 C4B 36E 36 930 922 957 985 C4B 42E 4...

Page 33: ...m Assembly Length D mm C4B 6LE 6 190 172 207 235 C4B 12LE 12 340 322 357 385 C4B 18LE 18 490 472 507 535 C4B 24LE 24 640 622 657 685 C4B 30LE 30 790 772 807 835 C4B 36LE 36 940 922 957 985 C4B 42LE 42...

Page 34: ...odel Beams Protection Zone K mm Overall Length B mm Install Length C mm Assembly Length D mm C4A 4M 4 205 188 223 251 C4A 8M 8 365 348 383 411 C4A 12M 12 525 508 543 571 C4A 16M 16 685 668 703 731 C4A...

Page 35: ...eams Protection Zone K mm Overall Length B mm Install Length C mm Assembly Length D mm C4A 4LM 4 210 188 223 251 C4A 8LM 8 370 348 383 411 C4A 12LM 12 530 508 543 571 C4A 16LM 16 690 668 703 731 C4A 2...

Page 36: ...odel Beams Protection Zone K mm Overall Length B mm Install Length C mm Assembly Length D mm C4A 4E 4 205 182 217 245 C4A 8E 8 365 342 377 405 C4A 12E 12 525 502 537 565 C4A 16E 16 685 662 697 725 C4A...

Page 37: ...eams Protection Zone K mm Overall Length B mm Install Length C mm Assembly Length D mm C4A 4LE 4 210 182 217 245 C4A 8LE 8 370 342 377 405 C4A 12LE 12 530 502 537 565 C4A 16LE 16 690 662 697 725 C4A 2...

Page 38: ...Safety Light Curtain C4 compact ME Series Installation Guide File Number CD1011 page 38 Date 12 April 2017 Figure N Declaration of Conformity...

Page 39: ...Safety Light Curtain C4 compact ME Series Installation Guide File Number CD1011 page 39 Date 12 April 2017 Figure O Glossary of Words and Language Translation...

Page 40: ...ng machine application must be complied with The safety light curtain is only one element in the overall machine safety circuit the whole machine safety control circuit must be a fail safe design The...

Page 41: ...s a certified quality assurance system in compliance with ISO 9001 2008 Certificate number 79Q13722 Products Smartscan safety light curtains are developed and manufactured in compliance with the Europ...

Page 42: ...eduction in optical efficiency reducing the effective range A guide to the practicality of using mirrors is given below Range of the light curtain Maximum range through 1 mirror Maximum range through...

Page 43: ...the Perspex window of the transmitter unit can be seen reflected in the mirror 6 If the light curtain is scanning over a long range it may be difficult to see the reflection of the transmitter units P...

Page 44: ...ft and to the right until the entire length of the transmitter unit is reflected through both the first mirror and the second mirror If difficulties are experienced in seeing the reflection of the tra...

Page 45: ...ed energy from the transmitter unit is being reflected through the mirror s to the corresponding receiver unit Alignment of the light curtain using mirrors Note The mirror length must be a minimum of...

Page 46: ...rs RX Green LED on OSSDs on Yellow LED EDM on Red LED on OSSDs off Yellow LED on Infrared beams aligned Top Yellow LED on Infrared beams aligned No signals quickly blinking yellow Not alignment slowly...

Page 47: ...d Per Hour 1 66958E 09 T1 Life Span in Years 20 Years MTTFd Years 100 Years or more DC Diagnostic Coverage 99 Warranty One Year OUTPUTS Safety Outputs OSSD1 OSSD2 2 x electronic switches PNP each rate...

Page 48: ...Safety Light Curtain C4 compact ME Series Installation Guide File Number CD1011 page 48 Date 12 April 2017 Notes...

Reviews: