Drive Startup Manual KEB-PM
Page 6
© 2019 Smartrise Engineering, Inc. All Rights Reserved
August 23,2019
Verify the LCD on the Smartrise board and the Magnetek Drive powers up.
Figure 5: Breakers
Encoder Cable
Proper connection of the encoder cable to the drive is key to a proper running elevator. Many
drive issues can be attributed to a defective encoder, encoder cable, or the encoder (or cable)
not installed properly.
The cable shall be kept a minimum of 8 inches (20 cm) away from all wires having greater than
24 VDC on them. For best results, run the encoder cable in a separate conduit from the
controller to the motor.
It is absolutely necessary to ensure these signals are well shielded! Noise on the analog signals
resulting from breaks in the shield or improper shield termination will result in vibration in the
motor and poor ride quality.
KEB Motor Learn
Smartrise programs the KEB drive with factory defaults to properly communicate with the
controller. After factory testing, customer motor data (from customer’s EDF) is programmed
into the drive to provide an e
asier “out of box” installation.
Summary of Contents for KEB-PM