background image

Specifications - 400VA/600VA

ENVIRONMENT

CONFORMANCE

SOFTWARE (UPSWING for Windows)

ALARM

PHYSICAL

BATTERY

PROTECTION & FILTERING

OUTPUT

0-40 deg C

OF400-TBF

OF400USB-TBF

OF600-TBF

400 / 200

3-NEMA 5-15R UPS + 3 NEMA 5-15R surge only

INPUT

MODEL

Ambient Temperature

Ambient Humidity

Warranty

Safety

Visual Indicators

Audible Warnings

Receptacles 

Input Inlet

Dimensions  D x W x H  (In./mm)

Shipping Weight (Lbs. / Kg.)

Net Weight (Lbs. / Kg.)

Back-up Time (half load)   Minutes

Type

Network

Communication Port

Overload and Short 
Circuit Protection

Spike Protection                (Joules)

Transfer Time

Frequency (on battery)

Voltage (on battery)

Capacity VA / W

Frequency

Voltage

0-90% humidity non-condensing

AC cord  6 ft. (5-15P) plug

cUL, UL, FCC

Site Wiring Fault, UPS On, On Battery, UPS Fault

On Battery, Battery Low, Overload, Fault

11.7 x 5.1 x 3.3 / 297 x 130 x 83.5

                

Sealed, maintenance-free lead acid

Electronic 

4 milli seconds, including detection time

120VAC ±10% Simulated sinewave

50/60Hz ±3Hz (auto sensing)

120 VAC - 20% +15%

50/60Hz ±1Hz

 RJ45

 RJ45

USB

 RJ45

10

9

Monitoring by Software

Software (optional)

Power failure, battery low, schedule UPS on/off, AC power status , battery / load level

<0.5V Common Mode (N-G)

None of the competitors publish N-G Pass Through Voltage

<10V Normal Mode (L-N)

Lowest Pass
Through Voltage

7.6 / 3.44

8.92 / 4.04

1710

Two years on the unit and $25,000 Lifetime Connected Equipment Warranty

OF600USB-TBF

600 / 300

 RJ45

USB

8.3 / 3.7

9.6 / 4.3

Specifications and features subject to change without notice. 

11

UPSWING PRO for Windows XP/ME/7/NT/2000/2003, SCO UNIX, Linux, Sun, Solaris, FreeBSD and others

Summary of Contents for OF400-TBF

Page 1: ...P N 16001400 Rev 3 17 USER S GUIDE Uninterruptible Power Supply 400VA 600VA Models Office TBF UPS Series OFFICE Series OF400 TBF OF400USB TBF OF600 TBF OF600USB TBF ...

Page 2: ... in a temperature and humidity controlled indoor area free of conductive contaminants Risk of Electric Shock Battery circuit is not isolated from AC input hazardous voltage may exist between battery terminals and ground Risk of Electric Shock Do not remove cover No user serviceable parts inside Refer servicing to qualified service personnel Risk of Electric Shock This unit receives power from more...

Page 3: ... of 61 and a maximum single harmonic distortion of 46 6 The output of the Office 600 is not sinusoidal It has a total harmonic distortion of 46 and a maximum single harmonic distortion of 33 TYPICAL BATTERY RUNTIME IN MINUTES Desktop PC with 15 monitor Desktop 15 monitor PC with Desktop 17 monitor PC with Desktop 17 monitor PC with OF400 OF600 ...

Page 4: ...eceptacle 6 Battery power plus power conditioning TBF receptacles Rear 7 AC input 8 Network Phne Line Protection 9 USB Port 10 Circuit breaker View USB Model Rear View 7 AC input 8 Telephone Line Protection 9 DB9 RS 232 Interface 10 Circuit breaker SmartPower SYSTEMS RS232 REAR VIEW OF400USB OF600USB REAR VIEW OF400 OF600 T10A 125VAC T10A 125VAC 10 10 ...

Page 5: ...econds and circuit breaker protected 1 UPS is not connected properly to the main power 2 Line breaker protected UPS is overloaded UPS output is short circuited possibly due to defective load 1 Connect the UPS according to the installa tion guide 2 Press the breaker Verify that the load matches the UPS capacity specified in the spec Disconnect your load from the UPS and then press the breaker Sympt...

Page 6: ...er failure Inspection Unpack the UPS carefully and note the packing method Retain the box and packing material for possible future shipment Visually inspect the UPS for freight damage Report damage to the carrier and your dealer Placement Install the UPS unit in any protected environment that provides adequate airflow around the unit and is free from excessive dust corrosive fumes and conductive c...

Page 7: ...e UPS to charge fully by leaving it plugged in for at least 8 10 hours with no load no electrical devices such as computers monitors etc connected Computer Connection Connect one computer related device into one of the battery supplied receptacles on the top of UPS Office Series UPSs provide six receptacles three battery supplied receptacles and three surge protected only receptacles 3 4 6 PC REAR...

Page 8: ...ght off Power failure or UTBF fault Contact customer service T10A 125VAC USB Connection with Network Protection OF USB models only connect the USB cable as shown in the diagram below To protect the Network connection plug incoming Network line into the in socket at the rear panel of the Office USB Series UPS Use provided CAT5 Network cable and plug one end to the Out socket at the rear panel of th...

Page 9: ...TAIL APPLICATION Bracket Installation To mount your Office UPS to a wall or other surface first install the provided EIP on the wall see Figure 1 by using the provided screws that will hold the EIP to the wall Make sure to place the unit where monitoring lights can be observed Figure 1 Easy Installation plate EIP Vertical Option BRACKET Horizontal Option Securing unit to wall Use the two mounting ...

Page 10: ...rt 2 Chart 3 9 Bottom View Bottom View Bottom View Remove the screws located on the bottom of the UPS to open the battery cover DC Start Function DC Start Function enables UPS to be started up when AC utility power is not available and battery is fully charged Just simply press the power switch to turn on the UPS Green Power Function All Office Series UPS are equipped with Green Power Function If ...

Page 11: ...ower condition analysis Online display of input output voltage and frequency battery capacity and load level Dashboard interface Send on line commands to UPS such as Test Shutdown Sleep and restart Extensive logging of all UPS operation and power quality data Event date analysis Events and data bar charts presentation Graphical display of power quality Run in background even before user login Free...

Page 12: ... 15P plug cUL UL FCC Site Wiring Fault UPS On On Battery UPS Fault On Battery Battery Low Overload Fault 11 7 x 5 1 x 3 3 297 x 130 x 83 5 Sealed maintenance free lead acid Electronic 4 milli seconds including detection time 120VAC 10 Simulated sinewave 50 60Hz 3Hz auto sensing 120 VAC 20 15 50 60Hz 1Hz RJ45 RJ45 USB RJ45 10 9 Monitoring by Software Software optional Power failure battery low sche...

Page 13: ...d to return the unit to the manufacturer you should obtain an RMA Return Material Authorization number before returning the unit To request an RMA number please call 1 800 772 7633 or visit the website at http smartpowersystems com support 2 rma If the Smart Power Systems equipment fails and this failure causes the surges to pass through and damage the connected equipment Smart Power Systems will ...

Page 14: ...1760 Stebbins Dr Houston TX 77043 1 800 882 8285 URL www smartpowersystems com Email support smartpowersystems com SmartPower SYSTEMS ...

Reviews: