Smartgen CMM366A-ET User Manual Download Page 4

                       

CMM366A-ET Cloud Monitoring Communication Module User Manual 

CMM366-ET Cloud Monitoring Communication Module          2017-12-21        Version 1.0        Page 4 of 15

 

1  OVERVIEW 

CMM366A-ET

 Cloud Monitoring Communication Module is an ETHERNET communication protocol 

switch module which can achieve genset (with SCI) connect to Internet. After logging into cloud server, 

module will receive corresponding genset controller communication protocol from cloud server. And the 

module  gains  genset  data  via  RS485  port,  USB  port,  LINK  port  or  RS232  port.  Then  the  module 

transmits  the  data  to  corresponding  cloud  server  via  wired  ETHERNET 

for achieving user’s real-time 

monitoring to running status and searching of running records via APP (IOS or Android) and pc terminal 

devices. 

CMM366A-ET

 module not only can achieve genset monitoring but also can insert some digital alarm 

input/output signal to achieve monitoring of generator room entrance guard, guard against theft and fire 

facilities. 

2  PERFORMANCE AND CHARACTERISTICS 

 

Connect to cloud server via wired ETHERNET, one to one monitoring; 

 

Multiple  ports  for  communication  with  genset  control  module:  RS485,  RS232,  LINK  and  USB 

(Host); can monitor great majority genset control modules of international first-class brands; 

 

Widely power supply: DC (8~35)V, can direct use genset build-in starter battery; 

 

With ARM-based 32-bit SCM, high integration of hardware and strong programming ability; 

 

Include with GPS locate function to achieve gain location information and locate genset; 

 

Take  JSON  network  data  communication  protocol,  upload  real-time  data  variation  and  take 

compression algorithm to vastly reduce network flow at the same time; 

 

When alarm occurs it can upload data to server immediately; 

 

2 auxiliary digital input ports which can receive external alarm signal; 

 

1 auxiliary relay output ports which can output various of alarm signal; 

 

Calendar and clock functions; 

 

Power and multiple communication status indicators on front panel that working status is clear at a 

glance; 

 

Lamp test function; 

 

Parameter adjust function: users can adjust parameters via USB port; 

 

Take standard 

π-type 35mm guide-rail installation or screw-fixed installation that the module can 

be installed in the genset control box; 

 

Modular  design,  self  extinguishing  ABS  plastic  shell,  light  weight,  compact  structure  with  easy 

installation. 

 

 

 

 

 

 

 

Summary of Contents for CMM366A-ET

Page 1: ...CMM366A ET CLOUD MONITORING COMMUNICATION MODULE USER MANUAL SMARTGEN ZHENGZHOU TECHNOLOGY CO LTD ...

Page 2: ...material form including photocopying or storing in any medium by electronic means or other without the written permission of the copyright holder Applications for the copyright holder s written permission to reproduce any part of this publication should be addressed to SmartGen Technology at the address above Any reference to trademarked product names used within this publication is owned by their...

Page 3: ...ERISTICS 4 3 SPECIFICATION 5 4 PANEL AND TERMINAL DESCRIPTION 6 4 1 PANEL INDICATOR AND BUTTONS 6 4 2 ETHERNET 7 4 3 RS485 7 4 4 RS232 7 4 5 LINK 8 4 6 USB HOST 8 4 7 USB DEVICE 8 4 8 TERMINAL 9 5 PROGRAMMABLE PARAMETERS 10 5 1 CONTENTS AND SCOPES OF PARAMETERS 10 5 2 PC CONFIGURATION INTERFACE 12 6 SYSTEM DIAGRAM 13 7 CASE DIMENSION AND INSTALLATION 14 8 TROUBLESHOOTING 15 9 PACKING LIST 15 ...

Page 4: ... Multiple ports for communication with genset control module RS485 RS232 LINK and USB Host can monitor great majority genset control modules of international first class brands Widely power supply DC 8 35 V can direct use genset build in starter battery With ARM based 32 bit SCM high integration of hardware and strong programming ability Include with GPS locate function to achieve gain location in...

Page 5: ...ly Power Consumption Standby 2W Working 5W Digital Input Volt free digital Input Relay Output 1A DC30V Volts free output USB Host A type USB female port RS485 Isolated type RS232 General type LINK SmartGen exclusive port USB Device B type USB female port ETHERNET RJ45 10 100Mbps self adaption network interface Case Dimensions 72 5mmx105mmx34mm Working Conditions Temperature 25 70 C Humidity 20 93 ...

Page 6: ... Extinguish USB Host disabled Normally Light Communication fail Blink Communication normal ETHERNET Red Normally Extinguish CMM366A ET login with server unsuccessfully Normally Light Login with server successfully Blink Real time communication normal LINK Red Normally Extinguish Disabled Normally Light Communication fail Blink Communication normal RS232 Red Normally Extinguish RS232 disabled Norma...

Page 7: ...e connect with router as follows Fig 2 ETHERNET Connet With Router 4 3 RS485 Receive genset data information by connecting module RS485 port with Genset Controller RS485 port If communication is abnormal 120Ω terminal resistance is recommonded One end of shield wire hangs in the air and the other one connects with SCR Fig 3 RS485 Connection 4 4 RS232 Receive genset data information by connecting m...

Page 8: ...ule LINK port with Genset Controller LINK port Fig 5 LINK Connection 4 6 USB HOST Receive genset data information by connecting module A type USB port female port with Genset Controller USB port via USB cable Fig 6 USB Host Connection 4 7 USB DEVICE All the parameters can be configured and view CMM366A ET ID Login password by connecting USB port with USB disk of PC software Fig 7 USB Connect PC De...

Page 9: ...y 2 B 1 0mm2 Connected with positive of starter battery 3A fuse is recommended 3 Digital Input 1 1 0mm2 Active when connect to B 4 Digital Input 2 1 0mm2 Active when connect to B 5 Relay Output Normally Open 1 0mm2 Normally open output with 1A DC30V 6 Common 1 0mm2 7 Normally Close 1 0mm2 8 RS485 B 0 5mm2 Impedance 120Ω shielding wire is recommended its single end earthed 9 RS485 A 0 5mm2 10 SCR 0...

Page 10: ...racters letters or numbers 2 URL 0 65535 www monitoryun com 40 characters 3 Server Port 0 65535 91 4 Security Code 0 65535 123456 16 characters GPS 1 Location Information 0 1 0 0 Disabled 1 Manual Input 2 Longitude 180 180 0 000000 GPS location altitude information 3 Latitude 90 90 0 000000 4 Altitude 9999 9 9999 9 m 100 0 Digital Input Digital Input 1 1 Setting 0 9 0 Default Not used 2 Type 0 1 0...

Page 11: ...is active 5 Alarm Input External alarm is uploaded to server when input is active 6 Reserved 7 Reserved 8 Reserved 9 Factory Test Mode It is only used for factory test when active Table 7 Relay Output Ports Content No Item Description 0 Not used Output port won t output when this item is selected 1 Digital Input 1 Active Output when auxiliary input 1 is active 2 Digital Input 2 Active Output when ...

Page 12: ...1 Version 1 0 Page 12 of 15 5 2 PC CONFIGURATION INTERFACE Connecting the USB port of CMM366A ET communication module with PC USB port to configure the parameters Fig 8 IP Configuration Through pressing ping key to test whether IP address is correct or not Fig 9 Gateway Configuration Fig 10 Module Monitoring Interface ...

Page 13: ...MM366 ET Cloud Monitoring Communication Module 2017 12 21 Version 1 0 Page 13 of 15 6 SYSTEM DIAGRAM One CMM366A ET module connects with one genset monitor module It can be connected via RS485 port LINK port RS232 port or USB port Fig 11 CMM366A ET System Diagram ...

Page 14: ...ng Communication Module 2017 12 21 Version 1 0 Page 14 of 15 7 CASE DIMENSION AND INSTALLATION 2 ways for installation 35mm guide rail in box or screw M4 installation as below Fig 12 CMM366A ET Case Dimension Fig 13 CMM366A ET Guide Rail Installation Fig 14 CMM366A ET Screw Installation ...

Page 15: ...5 Communication Abnormal Check connections Check RS485 port is enabled or not Check settings of genset ID and baud rate are correct or not Check RS485 s connections of A and B is reverse connect or not RS232 Communication Abnormal Check connections Check RS232 port is enabled or not Check settings of genset ID and baud rate are correct or not LINK Communication Abnormal Check connections Check LIN...