Smartgen BAC2405 User Manual Download Page 3

                                                     

BAC2405 BATTERY CHARGER USER MANUAL 

BAC2405 Battery Charger                Version 1.1                      2017-11-09                                  Page 5 of 7 

 

4  SPECIFICATION 

Items

 

Contents

 

Parameters 

Input 

Characteristics 

Nominal AC Voltage 

AC (100~240)V 

Max. AC Voltage 

AC (90~280)V 

AC Frequency 

50Hz/60Hz 

Max. Active Power 

164W 

Max. Current 

2.5A 

Max. Efficiency 

AC 110V 

AC 220V 

84% 

87% 

No-load 

Power 

Consumption 

<3W 

Output 

Characteristics 

No-load Output Voltage 

27.6V 

(Error±1%) 

Rated Charging Current 

5A 

(Error±2%) 

Max. Output Power 

135W 

Insulating Property 

Insulation Resistance 

Between  input  and  output,  input  and  shell  both  are: 

DC500V 1min R

L

500

MΩ 

Insulation Voltage 

Between  input  and  output,  input  and  shell  both  are: 

AC1500V 50Hz 1min;   

leakage current: I

L

3.5mA 

Working Condition 

Working Temperature 

(-30~+55)°C 

Storage Temperature   

(-40~+85)°C 

Working Humidity 

20%RH~93%RH ( No condensation) 

Shape Structure 

Weight 

0.66kg 

Dimension 

143mm×96mm×55mm (length*width*height) 

5  EFFICIENCY CURVE 

 

 
 

Summary of Contents for BAC2405

Page 1: ...BAC2405 BATTERY CHARGER USER MANUAL SMARTGEN ZHENGZHOU TECHNOLOGY CO LTD ...

Page 2: ...nt can be adjusted via potentiometer on the spot Suitable for 24V storage battery and the rated current is 5A LED display Power indication and charging indication 3 CHARGING PRINCIPLE Charging is performed according to the battery charging characteristics using two stage method Charging type is constant current type which means that when the battery terminal voltage falls below the pre set value c...

Page 3: ...put Characteristics No load Output Voltage 27 6V Error 1 Rated Charging Current 5A Error 2 Max Output Power 135W Insulating Property Insulation Resistance Between input and output input and shell both are DC500V 1min RL 500MΩ Insulation Voltage Between input and output input and shell both are AC1500V 50Hz 1min leakage current IL 3 5mA Working Condition Working Temperature 30 55 C Storage Temperat...

Page 4: ...d B to battery positive and negative using multi strand BVR1 5mm2 copper wires POWER power supply indicator illuminated when the charger is operating normally CHARGING charging indicator illuminated when charging current exceeds 0 5A while extinguished when charging current has fallen below 0 5A VOLT charging voltage regulator potentiometer AMP charging current regulator potentiometer FUSE output ...

Page 5: ... multimeter can be used to measure the fuse status a If output terminal 10A fuse is blown users only need to change the same capacity fuse b If output fuse isn t blown or battery without outputting after changing the fuse battery needs to depot repair c Fuse burn emergency method using conductive metal wire short connected burnt fuse and then change the fuse later 7 2 2 PROCEDURES OF CHANGING FUSE...

Reviews: