NB40LP1

REV 01 – Nov. 2018 - ENGLISH

MAINTENANCE

We   recommend   replacing   the   smoke   capsule   every   5
years using only the original replacement.

WARRANTY

SMARTEK   s.r.l.   It   guarantees   its   products   against   all
manufacturing defects for a period of 30 months from the
production date shown on the label.

RECOMMENDATIONS

Before   leaving,   ventilate   the   rooms   thoroughly   after   the
smoke has been delivered.

TECHNICAL SPECIFICATIONS

Power supply

3,6V lithium battery AA

size such as SAFT
LS14500 or similar

Minimum operating voltage

2,2V

Battery low output threshold

2,6V

Autonomy

About 10 years

Size

12cm x 17cm x 14cm

Saturable volume

100m

3

Weight

760g

Smoke average delivery time

25sec

Operating temperature

From 0°C to +45°C

Storage temperature

From -20°C to +55°C

Maximum relative humidity

70%

Inputs

SI – System state

ALL – Alarm

CSI – Immediate action

Outputs

24H – Tamper

ALL – Alarm

BL – Battery low

ADVANCED WIRING

The inputs interface mode can be programmed using the
DIP  switches   SW1,  SW2,  SW3  and   SW4   as   previously
explained.
The inputs can be controlled not only with clean contacts
but   also   with   open   collector   or   push-pull   outputs.   The
image below shows a typical NPN or PNP interface.

For any kind of interface, the inputs voltage thresholds are
the followed:

Min V

Max V

Level 0

GND

0,5V

Level 1

1,9V

+Vbatt

WORKING DIAGRAM

Summary of Contents for NUBI 4.0 NB40LP1

Page 1: ...tely The inputs polarity and logic level can be easily configured using the DIP switches in order to interface NUBI 4 0 with any burglar panel NUBI 4 0 has got two outputs to inform other devices about alarm state and the battery low The output logic level can be reversed using DIP switches The box opening is detected with a tamper switch its clean contact can be connected to the burglar panel An ...

Page 2: ... the supply voltage must not exceed 3 6V INPUTS INTERFACE When the DIP Switches 1 4 are set to OFF NUBI inputs will become active when switched to GND as shown in the following table CSI Trigger the smoke delivery when the input is closed to GND SI Burglar system armed when the input is closed to GND disarmed when opened ALL Burglar alarm active when the input is closed to GND With the DIP SW1 the...

Page 3: ... detection the alarm confirmation will be due to the activation of the ALL input If the pre alarm was caused by the activation of the ALL input the confirmation will occur whit the PIR detection In test mode the smoke cartridge will never be activated and never the validation card will be damaged Remember to activate the operating mode DIP SW7 OFF at the end of testing SMOKE CARTRIDGE REPLACEMENT ...

Page 4: ...6V Autonomy About 10 years Size 12cm x 17cm x 14cm Saturable volume 100m3 Weight 760g Smoke average delivery time 25sec Operating temperature From 0 C to 45 C Storage temperature From 20 C to 55 C Maximum relative humidity 70 Inputs SI System state ALL Alarm CSI Immediate action Outputs 24H Tamper ALL Alarm BL Battery low ADVANCED WIRING The inputs interface mode can be programmed using the DIP sw...

Reviews: