Smartek NUBI 4.0 F1 Quick Start Manual Download Page 2

6. DIP SWITCHES

DIP ON

OFF

1

Tamper disabled

Tamper active

2

Not used

Not used

3

OUT active to GND

OUT active open

4

CS input active at +12V

CS input active at GND

5

SI input active at +12V

SI input active at GND

6

ALL input active at +12V

ALL input active at GND

7

Power ON

Power OFF

8

Smoke enabled

Smoke disabled

7. DIAGNOSTIC LEDs

BLUE

Lampeggia durante il periodo di preallarme.

GREEN

A  brief   flash   indicates   the   triggering   of   the
smoke capsule. Useful during installation.

RED

Reports the smoke capsule is empty.

8. OUTPUTS

The 24H output is a clean contact
that is always closed when the box
is closed or the DIP1 is ON..

The OC output switch to GND for
90   seconds   after   the   smoke
capsule   run.   Useful   to   drive   the
internal siren or an external alarm
device.

The   OUT   output   become   active
when the smoke capsule is empty.
It can be active open or to GND,
according to DIP 3.

9. WALK TEST

Press   the   Walk   Test   button   to   activate   the   diagnostic
function for 10 minutes to turn on the blue LED every time
the   passive   infrared   detects   movement.   This   allows   to
position the device to obtain the maximum coverage of the
built-in infrared. When the Walk Test mode is active, the
next press of the button will stop it.

10. VALIDATION BOARD

The validation card is plugged to the
mother board and must be replaced
together   with   the   smoke   capsule
after   each   use.  A  flash   of   the   red
LED   indicates   that   the   capsule   is
not exhausted.

11. COMMISSIONING

IMPORTANT

: Keep OFF the DIP 7 and 8 during wiring.

Set DIP 7 to ON to power the board and carry out the
tests, only at the end of installation job put ON the DIP 8
to enable the smoke capsule.
The simulation tests of the smoke delivery keeping the
DIP 8 in the OFF position, can only be performed 

within

4 hours from the power supply of the board

, after

which the validation board will be irreparably consumed.
It   is   therefore   recommended   to   switch   OFF   and   ON
again the device with DIP 7 as the first thing to do in
case   of   maintenance   to   a   device   installed   for   a   long
time.

Before the final commissioning, it is advisable to carry out
both  the  Walk Test  and  some real  simulations,  with  the
DIP8 in the OFF position, where the green LED will emit a
short   flash   that   simulates   the   ignition   of   the   fumigation
capsule.

At   the  end  of  the  installation,   remove
the adhesive that protects smoke exit
hole of the smoke cartridge.

Installation manual NUBI F1

www.smarteksrl.it

Pag. 2 of 3

12. WORKING LOGIC

NUBI can be driven only with CS input (immediate discharge), or using the SI and ALL inputs in conjunction by the 
integrated infrared sensor. The operating logic is shown in the following diagram: