STANDARDS   AND   PROVISIONS:   Standards,   recommendations, 
regulations and  provisions of  the country in which the devices will 
operate, must be considered while planning and setting up electrical 
devices. Work on 230 VAC network is allowed for authorized personnel 
only.
DANGER   WARNINGS:   Devices   or   modules   must   be   protected   from 
moisture, dirt and damage during transport, storing and operation.
WARRANTY   CONDITIONS:   For   all   modules   LONGO   LPC-2   –   if   no 
modifications   are   performed   upon   and   are   correctly   connected   by 
authorized   personnel   –   in   consideration   of   maximum   allowed 
connecting power, we offer warranty for 24 months from date of sale 
to end buyer. In case of claims within warranty time, which are based 
on material malfunctions the producer offers free replacement. The 
method of return of malfunctioned module, together with description, 
can be arranged with our authorized representative. Warranty does 
not   include   damage   due   to   transport   or   because   of   unconsidered 
corresponding   regulations   of   the   country,   where   the   module   is 
installed.
This device must be connected properly by the provided connection 
scheme in this manual. Misconnections may result in device damage, 
fire or personal injury.
Hazardous  voltage   in  the  device  can  cause  electric  shock  and  may 
result in personal injury or death.
NEVER SERVICE THIS PRODUCT YOURSELF!
This device must not be installed in the systems critical for life (e.g. 
medical devices, aircrafts, etc.). 
If the device is used in a manner not specified by the manufacturer, 
the degree of protection provided by the equipment may be impaired.

Waste electrical and electronic equipment (WEEE) must be collected 
separately! 

LONGO LPC-2 complies to the following standards:

EMC:EN 61000-6-2 (EN 50082), EN 61000-6-4 (EN 50081)

LVD: IEC 61131-2

Vibrations and climatic-mechanical: EN 60068-2-6, EN 60068-2-27, 
EN 60068-2-29

Smarteh   d.o.o.   operates   a   policy   of   continuous   development. 
Therefore we reserve the right to make changes and improvements to 
any of the products described in this manual without any prior notice.

MANUFACTURER:
SMARTEH d.o.o.
Trg tigrovcev 1
5220 Tolmin
Slovenia

ii

Summary of Contents for LPC-2.CH1

Page 1: ...USER MANUAL Longo programmable controller LPC 2 CH1 special module Version 2 SMARTEH d o o Trg tigrovcev 1 5220 Tolmin Slovenia Tel 386 0 5 388 44 00 e mail info smarteh si www smarteh si...

Page 2: ...Longo programmable controller LPC 2 CH1 special module Written by SMARTEH d o o Copyright 2012 SMARTEH d o o User Manual Document Version 002 July 1 2012 i...

Page 3: ...e to transport or because of unconsidered corresponding regulations of the country where the module is installed This device must be connected properly by the provided connection scheme in this manual...

Page 4: ...ontroller LPC 2 CH1 special module 1 DESCRIPTION 1 2 FEATURES 2 3 OPERATION 3 3 1 Parameters 3 4 INSTALLATION 4 4 1 Connection scheme 4 4 2 Mounting frame selection 6 4 3 Mounting instructions 7 4 4 M...

Page 5: ...to the room the key card should be inserted to the CH1 card slot If card ID for correspondent room is valid several actions can be started e g room light and air conditioning switched on CH1 module fe...

Page 6: ...Table 1 Technical data RFID reader RFID card slot Adjustable LED intensity LEDs for showing activated messages requests do not disturb room service 2 touch buttons for activating messages requests do...

Page 7: ...bled or cleared Parameter can be status or command Parameter as status means that CH1 module is sending information to MCU On the other hand command represents request from MCU to module iComm Normal...

Page 8: ...Longo programmable controller LPC 2 CH1 special module 4 INSTALLATION 4 1 Connection scheme Figure 2 Connection scheme 4...

Page 9: ...st LED3 red FAULT X On RFID key standard NOK or ID card number wrong Off No tag in proximity LED4 green OK On RFID key standard OK and ID card number valid Off No tag in proximity LED5 red Communicati...

Page 10: ...CH1 module Bticino Living Light Gewiss Playbus System Vimar Plana Idea Tem Modul Soft Modul Line Master Frames of other vendors most probably suits as well but they were not verified by Smarteh Befor...

Page 11: ...to the main power supply Module should not be mounted outdoors Several RFID panels should not be mounted close to each other Minimum distance to next panel is at least 30 cm This restriction also app...

Page 12: ...cover plate LPC 2 CH1 connects to the MCU unit on its RS485 port using interconnection cable When more special modules e g LPC 2 CR1 LPC 2 CH1 LPC 2 DP1 are connected to MCU splitter is also required...

Page 13: ...es flush frame mounting module 01 derivation code 001 version code reserved for future HW and or SW firmware upgrades D C 10 10 is the date code 01 week and 10 year of production S N CH1 S9 1000000003...

Page 14: ...2 6 6 Power consumption 2W RFID type EM4100 125kHz Manchester 64 read only Max reading distance RFID card inserted into CH1 slot Dimensions W x H x D 75 x 49 x 29 mm Weight 40 g Ambient temperature 0...

Page 15: ...ler LPC 2 CH1 special module 6 CHANGES The following table describes all the changes to the document Date V Description 1 1 2012 002 CGP General update 1 10 2010 001 The initial version issued as LPC...

Page 16: ...Longo programmable controller LPC 2 CH1 special module 7 NOTES 12...

Reviews: