Longo programmable controller LPC-2.CA2M

STANDARDS   AND   PROVISIONS:   Standards,   recommendations,
regulations  and provisions  of  the  country  in  which  the  devices  will
operate, must be considered while planning and setting up electrical
devices. Work on  100 .. 240 V AC  network is allowed for authorized
personnel only.

DANGER   WARNINGS:   Devices   or   modules   must   be   protected   from
moisture, dirt and damage during transport, storing and operation.

WARRANTY   CONDITIONS:   For   all   modules   LONGO   LPC-2   –   if   no
modifications   are   performed   upon   and   are   correctly   connected   by
authorized   personnel   –   in   consideration   of   maximum   allowed
connecting power, warranty of 24 months is valid from the date of
sale to the end buyer, but not more than 36 months after delivery
from Smarteh. In case of claims within warranty time, which are based
on material malfunctions the producer offers free replacement. The
method of return of malfunctioned module, together with description,
can be arranged with our authorized representative. Warranty does
not   include   damage   due   to   transport   or   because   of   unconsidered
corresponding   regulations   of   the   country,   where   the   module   is
installed.

This device must be connected properly by the provided connection
scheme in this manual. Misconnections may result in device damage,
fire or personal injury.

Hazardous  voltage  in  the  device  can  cause  electric  shock  and  may
result in personal injury or death.

NEVER SERVICE THIS PRODUCT YOURSELF!

This device must not be installed in the systems critical for life (e.g.
medical devices, aircrafts, etc.).

If the device is used in a manner not specified by the manufacturer,
the degree of protection provided by the equipment may be impaired.

Waste electrical and electronic equipment (WEEE) must be collected
separately!

LONGO LPC-2 complies to the following standards:

EMC: EN 61000-6-3:2007 + A1:2011, EN 61000-6-1:2007, EN 61000-
3-2:2006 + A1:2009 + A2: 2009, EN 61000-3-3:2013

LVD: IEC 61010-1:2010 (3

rd

 Ed.), IEC 61010-2-201:2013 (1

st

 Ed.)

Smarteh   d.o.o.   operates   a   policy   of   continuous   development.
Therefore we reserve the right to make changes and improvements to
any of the products described in this manual without any prior notice.

MANUFACTURER:
SMARTEH d.o.o.
Poljubinj 114
5220 Tolmin
Slovenia

ii

Summary of Contents for LPC-2.CA2M

Page 1: ...USER MANUAL Longo programmable controller LPC 2 CA2M Card Reader module Version 1 SMARTEH d o o Poljubinj 114 5220 Tolmin Slovenia Tel 386 0 5 388 44 00 e mail info smarteh si www smarteh si...

Page 2: ...Longo programmable controller LPC 2 CA2M Written by SMARTEH d o o Copyright 2019 SMARTEH d o o User Manual Document Version 1 June 2019 i...

Page 3: ...ot include damage due to transport or because of unconsidered corresponding regulations of the country where the module is installed This device must be connected properly by the provided connection s...

Page 4: ...controller LPC 2 CA2M 1 DESCRIPTION 1 2 FEATURES 2 3 OPERATION 3 3 1 Parameters 3 4 INSTALLATION 4 4 1 Connection scheme 4 4 2 Mounting frame selection 6 4 3 Mounting instructions 7 4 4 Module labelin...

Page 5: ...ly read out In case key card for correspondent room is valid the green LED blinks again and a short beep is generated Other devices can be activated at this event like door lock opening turning light...

Page 6: ...and white glass version Table 1 Features RFID reader LEDs for showing activated messages requests occupied do not disturb room service SOS OK LED FAULT LED Power LED Internal fault LED Internal built...

Page 7: ...is considered to be active enabled or set If parameter has logical value 0 is considered to be inactive disabled or cleared Parameter can be status or command Parameter as status means that CA2M modu...

Page 8: ...Longo programmable controller LPC 2 CA2M 4 INSTALLATION 4 1 Connection scheme Figure 2 Connection scheme 4...

Page 9: ...ED3 red FAULT X On RFID key standard NOK or ID card number wrong Off No tag in proximity LED4 green OK On RFID key standard OK and ID card number valid Off No tag in proximity LED5 blue SOS On request...

Page 10: ...g metal frames and metal cover plate Mounting instructions 1 Set the correct RS 485 address S1 switch for LPC 2 CA2M refer to the Table 4 2 Drill a hole for cable inlet on desired side and position of...

Page 11: ...uct name CCDDD sequence code CC year of code opening DDD derivation code EEE version code reserved for future HW and or SW firmware upgrades 3 S N SSS RR YYXXXXXXXXX serial number SSS short product na...

Page 12: ...odule Interconnection connector type RJ 12 6 6 Power consumption 1 W RFID type ISO IEC 14443 A MIFARE Max reading distance 4 cm Dimensions W x H x D 120 x 80 x 60 mm Weight 200 g Ambient temperature 0...

Page 13: ...ngo programmable controller LPC 2 CA2M 6 CHANGES The following table describes all the changes to the document Date V Description 14 07 19 1 The initial version issued as LPC 2 CA2M module UserManual...

Page 14: ...Longo programmable controller LPC 2 CA2M 7 NOTES 10...

Reviews: