USER’S MANUAL PAGE 13
WBC-250
BATTERY CHARGING TIMES
Ah
- Ampere Hours
CCA
- Cold Cranking Amps
RC
- Reserve Capacity
MO
- Maintain Only
Use the following table to determine the time it will take to bring a battery to
full charge.
BATTERY SIZE/RATING(6V/12V)
CHARGE
RATE/TIME
6A<>2A
SMALL BATTERIES
6-12 Ah
1½ - 2½ h
Motorcycle, garden tractor, etc.
12-32 Ah
2½ - 7½ h
CARS/
TRUCKS
200-315 CCA
40-60 RC
7½ - 9½ h
315-550 CCA
60-85 RC
9½ - 13½ h
550-1000 CCA
85-190 RC
12-23 h
OVER-TEMP
/
Output current reduces to 0 when
temperature in charger is too high.
(exceeds 269.6˚/132˚). After cooling
down for a few minutes, the charger
will automatically begin charging with
6<>2A CHARGE/MAINTAIN rate if a
battery is connected, and the battery
type has memory
function and is the same as before.
BAD-BATT
/
The battery cannot store electric
charge (dead battery) after 3-minute
analysis
(ANALYSING-2
Display).