7.4. Strobe Controller Status
When a connection between ScLibClient and controller is established, all fields are read out in
controller status. Controller status is defined in the lower left corner of the ScLibClient software:
• Controller Model – shows the model of the strobe controller.
• User defined name – shows the name of the strobe controller, it can be changed by the user.
• Light head Model – shows the model of the light head connected to the controller. If the light
head does not have a digital ID, or it is not connected to the controller, the field will be empty
• Unique Address – shows the mac address of the strobe controller.
• Temperature [°C] – shows the internal temperature of the strobe controller. At the beginning
this field is zero. Controller temperature sensor needs a few seconds to read the exact
temperature. Normal internal temperature is from -5°C to +50°C (+23°F to +122°F).
• Fault Code – internal error code, described in chapter 5.2.1 - Ethernet Status
• Input Voltage [V] – shows the controller input power supply voltage.
• Max Input Power [W] – shows the maximal power of input power supply.
Figure 31: ScLibClient
– Strobe Controller Status Output
7.5. Applying a Configuration
The ScLibClient has functions to read,
send and store configurations. The
Read
button is used for reading the complete
parameter-set running currently on the
controller, while the
Send & Save
button applies and stores the desired parameters to the
device.
Additionally, devices of the latest generation support also the application of parameters only to
the running configuration, using the
Send
button. These values are stored to volatile memory
and will be dropped on power cycle or reset of the device.