SmartDHOME MyOT 01335-2080-00 User Manual Download Page 6

MyOT interface/actuator for OpenTherm Boilers 

User manual

 

 

 

2 flashing every 3 seconds 

The MyOT device is working and there is 

no request for heating. 

LED on and with 2 shutdowns every 3 

seconds 

The MyOT device is working and there is a 

request for heating. 

 
The flashing red LED indicates anomalies: 
 

2 f pause 

No communication on the OpenTherm bus. 

3 f pause 

Radio transmission issues on the Sigfox 

module. 

4 f pause 

No communication on the MODBUS (if 

enable). 

5 f pause 

No Wi-Fi connection and/or Internet 

communication. 

 
Wi-Fi Error. Possible causes: 

 

No connection to the local network. 

 

No connection to the SmartDHOME server (no Internet connection, server 
temporarily unavailable, etc). 

 

 
Wi-Fi Configuration 
 

WARNING! 

The device has several communication modes that cannot be configured at the 

same time. Choose the one you prefer before proceeding with configuration. 

 

WI-FI Configuration using application (recommended) 

To configure the device, download and install the IoB application on your smartphone. After 
that, set the MyOT in programming mode, turn on the device and press the functions button 
for 3 seconds. 
Upon release of the button, the device will enter configuration mode and the LEDs will flash 
alternately (red and green). In this way, you will can connect to a new Wi-Fi called “IoB” to 
begin the device configuration. 

Summary of Contents for MyOT 01335-2080-00

Page 1: ...or for OpenTherm boilers the latest generation device that allows you to monitor the performance of the OpenTherm boilers on which it is installed Z Wave certified it is compatible with any gateway th...

Page 2: ...near sharp or abrasive objects prevent people from walking on them 8 Keep out of reach of children 9 Do not carry out any maintenance on the device but always contact the assistance network 10 Contac...

Page 3: ...e waste collection service or the center where you purchased the product Disclaimer SmartDHOME Srl cannot guarantee that the information regarding the technical characteristics of the devices in this...

Page 4: ...dictive Maintenance process the implementation of automatic customer support processes Features Z Wave protocol Series 500 Radio signal power 1mW Radio frequency 868 4 MHz EU 908 4 MHz US 921 4 MHz AN...

Page 5: ...to IoB cloud A few tips that can aid you 1 Boiler and Thermostat OpenTherm connections have no polarization 2 Pay close attention to the 5V power connection respecting the and 3 Pay close attention t...

Page 6: ...s No connection to the local network No connection to the SmartDHOME server no Internet connection server temporarily unavailable etc Wi Fi Configuration WARNING The device has several communication m...

Page 7: ...o end the process press the CLOSE button on the top right The LEDs on the MyOT device will stop flashing alternately At the end of the Device Configuration the IoB will be operational with the new con...

Page 8: ...dwifi the Key of the Wi Fi chosen A white screen with the inscription OK will be displayed 7 Open the browser and enter the following third link http 192 168 4 1 exit A white screen with the inscripti...

Page 9: ...ed to manage the setpoints of the boiler Is important to known that the max and min value of these setpoints are not reported by this command class the reported values are just a small minimum and a b...

Page 10: ...1 Boiler heating modulation 0x3E 62 Boiler water temperature 0x3F 63 DHW Temperature COMMAND_CLASS_CONFIGURATION This command class maps a series of parameters that are obtained from the boiler The ma...

Page 11: ...nd customer support Visit our website at the link http www ecodhome com acquista garanzia eriparazioni html If you encounter technical problems or malfunctions visit the site http helpdesk smartdhome...

Reviews: