SmartDHOME MyOT 01335-2080-00 User Manual Download Page 1

MyOT interface/actuator for OpenTherm Boilers 

User manual

 

 

 

Thank you for choosing the interface / actuator for OpenTherm boilers, the latest generation 
device that allows you to monitor the performance of the OpenTherm boilers on which it is 
installed. Z-Wave certified, it is compatible with any gateway that communicates through this 
protocol such as MyVirtuoso Home. 

 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

www.myvirtuosohome.com

 

www.smartdhome.com

 

 
 

Summary of Contents for MyOT 01335-2080-00

Page 1: ...or for OpenTherm boilers the latest generation device that allows you to monitor the performance of the OpenTherm boilers on which it is installed Z Wave certified it is compatible with any gateway th...

Page 2: ...near sharp or abrasive objects prevent people from walking on them 8 Keep out of reach of children 9 Do not carry out any maintenance on the device but always contact the assistance network 10 Contac...

Page 3: ...e waste collection service or the center where you purchased the product Disclaimer SmartDHOME Srl cannot guarantee that the information regarding the technical characteristics of the devices in this...

Page 4: ...dictive Maintenance process the implementation of automatic customer support processes Features Z Wave protocol Series 500 Radio signal power 1mW Radio frequency 868 4 MHz EU 908 4 MHz US 921 4 MHz AN...

Page 5: ...to IoB cloud A few tips that can aid you 1 Boiler and Thermostat OpenTherm connections have no polarization 2 Pay close attention to the 5V power connection respecting the and 3 Pay close attention t...

Page 6: ...s No connection to the local network No connection to the SmartDHOME server no Internet connection server temporarily unavailable etc Wi Fi Configuration WARNING The device has several communication m...

Page 7: ...o end the process press the CLOSE button on the top right The LEDs on the MyOT device will stop flashing alternately At the end of the Device Configuration the IoB will be operational with the new con...

Page 8: ...dwifi the Key of the Wi Fi chosen A white screen with the inscription OK will be displayed 7 Open the browser and enter the following third link http 192 168 4 1 exit A white screen with the inscripti...

Page 9: ...ed to manage the setpoints of the boiler Is important to known that the max and min value of these setpoints are not reported by this command class the reported values are just a small minimum and a b...

Page 10: ...1 Boiler heating modulation 0x3E 62 Boiler water temperature 0x3F 63 DHW Temperature COMMAND_CLASS_CONFIGURATION This command class maps a series of parameters that are obtained from the boiler The ma...

Page 11: ...nd customer support Visit our website at the link http www ecodhome com acquista garanzia eriparazioni html If you encounter technical problems or malfunctions visit the site http helpdesk smartdhome...