background image

Dual mount motion and occupancy sensor 

User manual

 

 

Rev. 1 del 10.11.2022 

Pag.  9/9 

 

 

 

3. Do not open the detector, 
contact supplier. 

The detector does not stay 
awake for 10 minutes. 

Check if detector is out of order. 

Please make sure button is 
pressed 3 times within 1.5 sec. If 
detector still fails to stay awake 
for 10 seconds, repeat this step 
until it is successful. 

 

Disposal

 

Do not dispose of electrical appliances in mixed urban waste, use separate collection services. Contact the 
local  council  for  information  about  available  collection  systems.  If  electrical  appliances  are  disposed  of  in 
landfills or in inappropriate places, hazardous substances can escape into groundwater and enter the food 
chain, damaging health and well-being. When replacing old appliances with new ones, the retailer is legally 
obliged to accept the old appliance for free disposal.

 

 

Warranty and customer support 

Visit our website: 

http://www.ecodhome.com/acquista/garanzia-eriparazioni.html

   

 

If you encounter technical problems or malfunctions, visit the site: 

http://helpdesk.smartdhome.com/users/register.aspx

     

 

After  a  short  registration  you  can  open  a  ticket  online,  also  attaching  images.  One  of  our  technicians  will 
answer you as soon as possible. 

 

 

 

 

 

     

 

 

SmartDHOME Srl 

V.le Longarone 35, 20058 Zibido San Giacomo (MI) 

Product code: 01335-1900-00 

[email protected]

 

 

 

Summary of Contents for 01335-1900-00

Page 1: ...ual Rev 1 del 10 11 2022 Pag 1 9 Thank you for choosing the dual mount motion and occupancy sensor Z Wave certified the device is compatible with the gateways of the MyVirtuoso Home home automation sy...

Page 2: ...nal a If the product has come into contact with water or liquid substances b If the product has suffered obvious damage to the container c If the product does not provide performance conforming to its...

Page 3: ...ivities We reserve the right to modify components accessories technical data sheets and related product documentation at any time without notice On the website www myvirtuosohome com the documentation...

Page 4: ...e relevant manual available on the website www myvirtuosohome com downloads 1 Press the pairing button 3 consecutive times within 1 5 seconds The sensor will emit a beep when the button is pressed Not...

Page 5: ...heat e g fires radiators boiler etc 3 Ensure the detector is positioned in place where the light source detected by the sensor is consistent with actual ambient illumination Do not locate the detecto...

Page 6: ...gles shown in FIGURE 4b and FIGURE 5b Hold the rear cover in position and mark the two mounting holes Drill the holes insert the plastic rawl plugs and screw the rear cover to the wall or ceiling usin...

Page 7: ...a is to be used when the detector is wall mounted Ceiling lens cover FIGURE 6b is to be used when the detector is ceiling mounted The coverage range adjustment is only applicable to ceiling lens cover...

Page 8: ...d with a shading cap which retains 12 lens segments Warm up It will take approximately 2 minutes to warm up after battery has been connected During this period the detector beeps once every 3 seconds...

Page 9: ...ances are disposed of in landfills or in inappropriate places hazardous substances can escape into groundwater and enter the food chain damaging health and well being When replacing old appliances wit...