Step 1:
Turn off the equipment that is plugged into the output of the UPS.
Step 2:
Turn off the UPS.
Step 3:
Remove AC input plug of the UPS from the AC wall outlet.
Step 4:
Remove all equipment from the output sockets of the UPS.
Step 5:
Remove the battery cover by pushing down the front panel.
Step 6:
Disconnect the battery connector. Then, slide out the existing battery pack from the UPS by
grasping the battery pull tap.
Caution -
Do not short the positive wire and negative wire of battery.
Caution -
DO NOT pull the battery pack out by pulling on the battery wires.
Step 7:
Slide the new battery pack into the UPS.
Step 8:
Verify proper polarity. Re-connect the battery connectors together.
NOTE-
Some sparking might occur and this is normal.
Step 9:
Reinstall the battery cover onto the UPS. Now, the UPS is ready for normal operation.
NOTICE:
Properly dispose of the old batteries at an appropriate recycling facility or return them to the
supplier in the packing material for the new batteries.
Step 5
Step 6
Battery
Replacement
UPS
User´s Manual
17
/ EN
This UPS is designed with easy battery replacement.
Please follow below steps to replace the inside batteries.