Plug in the charger to AC mains (100 - 240V) wall socket.
The indicatiors light up one by one as charger goes through a series of self checks. Then all lights are
on together and off to indicate the end of checks except the operation “Standby” indicator.
Connect the red output lead to the positive terminal of the battery and the black lead to the negative
teminal.
The “Standby” blinks to indicate that charger is ready for selection of Charge Mode.
User has 2 minutes to select the desired Charge Mode, and the charger will automatically enters into
the last selected Charge Mode at the end of 2 minutes.
Select the appropiate Charge Mode by pressing the Mode button one or more times within 2 minutes.
The Charge Mode indicator changes with each press “Motor Cycle”
→
“Car “
→
“Snow”
→
“Motor
Cycle” in cycle.
The Mode button will also be locked in 10 seconds after selection of Charge Mode.
If no pressing on the Mode key has been done after 2 minutes, the charger will automatically enters
into the last selected charging mode.
Display
Indications
Standby Mode
d
Steady light on :
AC mains connected but charger is not yet connected to battery.
Blinking light on :
Battery is connected, 2 minutes to select charge mode before charger enters to last
selected Charge Mode.
Check Mode
h
Steady light on :
For a few seconds initially for normal battery, charger checking battery.
Steady light on :
For longer time, charger in *desulphate charging.
Blinking light on :
When connected to battery showing the battery is not suitable for charge.
Blinking light on :
After unit in Charging Mode for long time (max. 40 hrs.), or desuphating charge
(max.8 hrs.), battery still cannot hold charge or cannot be desuphated. Remove
battery .
Charging Mode
i
Steady light on :
Charging in progress (desulphate and bulk or absorption charge stage)
Float / Maintenance Charge Mode
j
Steady light on :
Battery is fully charged and Charger in Float / Maintenance Pulse Mode
Alarm
k
The blinking alarm indicates charging fault, check following faults.
Output connectors short circuit
Output connectors in wrong polarity
Over temperature Protection activated, charging has stopped.