68
ATCA-F125 (6873M Artwork) Installation and Use (6806800J94N)
Controls, LEDs, and Connectors
Controls, LEDs, and Connectors
3.8
Switches
Mechanical switches are provided for debug configuration options. All switch settings are
OFF by default. Setting any switches to the ON state may conflict with normal operating
modes.
Table 3-23
Switch Settings
Switch
Options
Default
SW1.1
Manual power enable of 12V
OFF: 12V power is controlled by IPMI
ON: Enable 12V
OFF
SW1.2
Manual power enable of POL
OFF: POL power is controlled by IPMI
ON: Enable POL supplies by initiating power up sequence
OFF
SW1.3
Manual power enable of AMC and RTM
OFF: AMC and RTM power is controlled by IPMI
ON: Enable AMC and RTM power
OFF
SW1.4
Disable IPMC Watchdog Timer
OFF: Watchdog timer is enabled
ON: Disable IPMC Watchdog Timer
OFF