14
RTM-ATCA-F125 Installation and Use (6806800K30J)
Safety Notes
Safety Notes
To ensure EMC protection use only shielded cables when connecting peripherals to assure
that appropriate radio frequency emissions compliance is maintained. Installed blades
must have the face plates installed and all vacant slots in the shelf must be covered.
Installation
Damage of the RTM and Additional Devices and Modules
Incorrect installation or removal of additional devices or modules may damage the RTM or
the additional devices or modules.
Before installing or removing additional devices or modules, read the respective
documentation.
Damage of Circuits
Electrostatic discharge and incorrect installation and removal of the RTM can damage
circuits or shorten its life.
Before touching the RTM or electronic components, make sure that you are working in an
ESD-safe environment.
Damage of the RTM
Incorrect installation of the RTM can cause damage of the RTM.
Only use handles when installing/removing the RTM to avoid damage/deformation to the
face plate and/or PCB.
Damage to RTM/Backplane or System Components
Bent pins or loose components can cause damage to the RTM, the backplane, or other
system components.
Carefully inspect the RTM and the backplane for both pin and component integrity before
installation.
SMART EC and our suppliers take significant steps to ensure there are no bent pins on the
backplane or connector damage to the blades/RTMs prior to leaving the factory. Bent pins
caused by improper installation or by inserting blades with damaged connectors could void
the SMART EC warranty for the backplane or blades.
System Damage
WARNING: The intra-building port (s) of the equipment or subassembly is suitable for
connection to intra-building or unexposed wiring or cabling only. The intra-building port (s)
of the equipment or subassembly MUST NOT be metallically connected to interfaces that
connect to the outside plant (OSP) or its wiring. These interfaces are designed for use as
intrabuilding interfaces only (Type 2 or Type 4 ports as described in GR-1089) and require
Summary of Contents for 6806800K30J
Page 1: ...RTM ATCA F125 Installation and Use P N 6806800K30J November 2020...
Page 6: ...List of Figures 6 RTM ATCA F125 Installation and Use 6806800K30J...
Page 8: ...List of Tables 8 RTM ATCA F125 Installation and Use 6806800K30J...
Page 24: ...24 RTM ATCA F125 Installation and Use 6806800K30J Introduction Introduction...
Page 48: ...48 RTM ATCA F125 Installation and Use 6806800K30J Related Documentation Related Documentation...
Page 49: ...1...